{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"SR2D101FU","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"SR2D101FU","canonicalUrl":"https://aoctrl.com/schneider/SR2D101FU","factsUrl":"https://aoctrl.com/api/mcp/products/SR2D101FU","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Zelio Logic compact smart relay, SR2D101FU, 100-240 V AC supply, 6 discrete inputs, relay outputs, without display or clock.","salesMarkdown":"The SR2D101FU: No built-in clock (: Without) means this unit cannot execute time-based schedules internally. If your application needs timed events, you'll need to add an external RTC module or rely on a controller upstream. Each power-up, the unit performs a program memory integrity check (: Program memory on each power up). This adds a few milliseconds to startup but ensures the logic hasn't been corrupted—useful for unattended or safety-related installations. The 10-year backup time at 25 °C means the program and data are retained without external battery—one less item to track in the spares cabinet. With six discrete inputs sensing 100–240 V AC and a cycle time of 6–90 ms, this relay is sized for simple on/off control of pumps, conveyors, or lighting panels where sub-second response is acceptable.","metaTitle":"Schneider SR2D101FU Zelio Logic Smart Relay, 6 Inputs, No Cl","metaDescription":"Active production. No real-time clock. 6 AC inputs, relay outputs. Screw terminals. Program memory check on power-up. Source via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Clock":"Without","Checks":"Program memory on each power up","Category":"US1000I22378","Standards":"IEC 60068-2-27 Ea IEC 60068-2-6 Fc IEC 61000-4-12 IEC 61000-4-4 level 3 IEC 61000-4-5 IEC 61000-4-2 level 3 IEC 61000-4-11 IEC 61000-4-3 IEC 61000-4-6 level 3","Cycle time":"6...90 ms","Backup time":"10 years 77 °F (25 °C)","Clock drift":"12 min/year 32...131 °F (0...55 °C) 6 s/month 77 °F (25 °C)","Local display":"Without","Response time":"50 ms ladder from state 0 to state 1)discrete input 50 ms ladder from state 1 to state 0)discrete input 50...255 ms FBD from state 0 to state 1)discrete input 50...255 ms FBD from state 1 to state 0)discrete input 10 ms from state 0 to state 1)relay output 5 ms from state 1 to state 0)relay output","Protection Type":"Against inversion of terminals (control instructions not executed)","lifecycle_stage":"current","Pollution degree":"2 IEC 61131-2","Range of Product":"Zelio Logic","Supply frequency":"50/60 Hz","Isolation voltage":"1780 V","Relative Humidity":"95 % without condensation or dripping water","Tightening Torque":"4.4 lbf.in (0.5 N.m)","Operating altitude":"6561.68 ft (2000 m)","Operating rate in Hz":"0.1 Hz at Ie)relay output 10 Hz no load)relay output","Overvoltage category":"III conforming to IEC 60664-1","Discrete input number":"6","Mechanical durability":"10000000 cycles relay output","Nbr. of units in pkg.":"1","Supply voltage limits":"85...264 V","Discrete input current":"0.6 mA","Discrete input voltage":"100...240 V AC","Maximum supply current":"30 mA 240 V without extension) 80 mA 100 V without extension)","Connections - terminals":"Screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 25...AWG 14) semi-solid Screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 25...AWG 14) solid Screw terminals, 1 x 0.25...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end Screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) solid Screw terminals, 2 x 0.25...2 x 0.75 mm² AWG 24...AWG 18) flexible with cable end","IP degree of protection":"IP20 IEC 60529 terminal block) IP40 IEC 60529 front panel)","Immunity to microbreaks":"10 ms","Power consumption in VA":"7 VA without extension","Discrete input frequency":"47...53 Hz 57...63 Hz","Product or Component Type":"Compact smart relay","[Us] rated supply voltage":"100...240 V AC","Current state 0 guaranteed":"= 10 mA 12 V relay output)","Maximum altitude transport":"10000 ft (3048 m)","Voltage state 0 guaranteed":"= 0.17 mA discrete input)","Voltage state 1 guaranteed":">= 79 V discrete input","Environmental characteristic":"EMC directive conforming to IEC 61000-6-2 EMC directive conforming to IEC 61000-6-3 EMC directive conforming to IEC 61000-6-4 EMC directive conforming to IEC 61131-2 zone B Low voltage directive conforming to IEC 61131-2","Disturbance radiated/conducted":"Class B EN 55022-11 group 1","Number or control scheme lines":"240 ladder","Ambient Air Temperature for Storage":"-40...158 °F (-40...70 °C)","Ambient air temperature for operation":"-4...104 °F (-20...40 °C) in non-ventilated enclosure IEC 60068-2-1 and IEC 60068-2-2 -4...131 °F (-20...55 °C) IEC 60068-2-1 and IEC 60068-2-2","[Uimp] rated impulse withstand voltage":"4 kV EN/IEC 60947-1 and EN/IEC 60664-1"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$62.23","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/51f1f3cee6264b55cec6778d04cb0a09.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/SR2D101FU/alternatives.json"},"ai":{"faq":[{"question":"Does the SR2D101FU have a real-time clock?","answer":"No, the listed clock status is 'Without'. Time-based scheduling requires an external RTC or a higher-tier Zelio Logic module."},{"question":"What checks does the SR2D101FU perform on startup?","answer":"It checks program memory on each power-up to verify integrity before entering run mode."},{"question":"What compliance documentation does the SR2D101FU carry?","answer":"It conforms to IEC 60068 environmental tests, IEC 61000 EMC standards at performance level 3, IEC 61131-2 for programmable controllers, and the EMC directive for class B emissions."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/SR2D101FU","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/SR2D101FU when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}