{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"SR2PACKFU","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"SR2PACKFU","canonicalUrl":"https://aoctrl.com/schneider/SR2PACKFU","factsUrl":"https://aoctrl.com/api/mcp/products/SR2PACKFU","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Zelio Logic compact discovery pack, 12 I/O (8 discrete inputs, 4 relay outputs), 100-240 VAC supply, cycle time 6-90 ms, with local display and real-time clock.","salesMarkdown":"## Smart relay with built-in RTC and display The Schneider Electric SR2PACKFU is a Zelio Logic compact discovery pack combining a smart relay with 12 I/O: 8 discrete inputs (100-240 VAC, 0.6 mA) and 4 relay outputs. It runs on 100-240 VAC supply, 50/60 Hz, and has a cycle time of 6 to 90 ms. A local display and real-time clock are included; the clock maintains time for 10 years at 25°C without power, with drift of 12 min/year over 0-55°C or 6 s/month at 25°C. The base unit checks program memory on each power-up. Supply voltage limits are 85-264 VAC, so it handles nominal 120 V or 240 V lines with brownout margin. At 240 V the module draws 30 mA (without extension); at 100 V it draws 80 mA. Inputs are 100-240 VAC, sinking 0.6 mA each — straight off the line, no separate sensor supply needed. Relay outputs switch at 0.1 Hz at rated current (10 Hz no-load), mechanical durability 10 million cycles. Isolation voltage 1780 V. IP20 on terminals, IP40 front panel.","metaTitle":"Schneider Electric SR2PACKFU Zelio Logic Compact Smart Relay","metaDescription":"SR2PACKFU Zelio Logic compact discovery pack with 12 I/O (8 inputs, 4 relay outputs), RTC, 100-240 VAC supply, cycle time 6-90 ms. Active production. RFQ for quantity.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Clock":"With","Checks":"Program memory on each power up","Category":"US1000I22378","Standards":"IEC 61000-4-2 level 3 IEC 61000-4-12 IEC 61000-4-11 IEC 61000-4-3 IEC 60068-2-6 Fc IEC 61000-4-6 level 3 IEC 60068-2-27 Ea IEC 61000-4-5 IEC 61000-4-4 level 3","Cycle time":"6...90 ms","Backup time":"10 years 77 °F (25 °C)","Clock drift":"12 min/year 32...131 °F (0...55 °C) 6 s/month 77 °F (25 °C)","Local display":"With","Response time":"50 ms ladder from state 0 to state 1)discrete input 50 ms ladder from state 1 to state 0)discrete input 50...255 ms FBD from state 0 to state 1)discrete input 50...255 ms FBD from state 1 to state 0)discrete input 10 ms from state 0 to state 1)relay output 5 ms from state 1 to state 0)relay output","Kit composition":"SR2B121FU Cable PC SR2USB01 for connection to PC","Protection Type":"Against inversion of terminals (control instructions not executed)","lifecycle_stage":"current","Pollution degree":"2 IEC 61131-2","Range of Product":"Zelio Logic","Supply frequency":"50/60 Hz","Isolation voltage":"1780 V","Number of outputs":"4 relay","Relative Humidity":"95 % without condensation or dripping water","Tightening Torque":"4.4 lbf.in (0.5 N.m)","Operating altitude":"6561.68 ft (2000 m)","Input/output number":"12","Operating rate in Hz":"0.1 Hz at Ie)relay output 10 Hz no load)relay output","Overvoltage category":"III conforming to IEC 60664-1","Discrete input number":"8","Mechanical durability":"10000000 cycles relay output","Nbr. of units in pkg.":"1","Supply voltage limits":"85...264 V","Discrete input current":"0.6 mA","Discrete input voltage":"100...240 V AC","Maximum supply current":"30 mA 240 V without extension) 80 mA 100 V without extension)","Connections - terminals":"screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 25...AWG 14) semi-solid screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 25...AWG 14) solid screw terminals, 1 x 0.25...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) solid screw terminals, 2 x 0.25...2 x 0.75 mm² AWG 24...AWG 18) flexible with cable end","IP degree of protection":"IP20 IEC 60529 terminal block) IP40 IEC 60529 front panel)","Immunity to microbreaks":"10 ms","Power consumption in VA":"7 VA without extension","Discrete input frequency":"47...53 Hz 57...63 Hz","Product or Component Type":"Compact discovery packs","[Us] rated supply voltage":"100...240 V","Current state 0 guaranteed":"= 10 mA 12 V relay output)","Maximum altitude transport":"10000 ft (3048 m)","Voltage state 0 guaranteed":"= 0.17 mA discrete input)","Voltage state 1 guaranteed":">= 79 V discrete input","Environmental characteristic":"EMC directive IEC 61000-6-2 EMC directive IEC 61000-6-3 EMC directive IEC 61000-6-4 EMC directive IEC 61131-2 zone B low voltage directive IEC 61131-2","Disturbance radiated/conducted":"Class B EN 55022-11 group 1","Number or control scheme lines":"120 ladder 0...200 FBD","Ambient Air Temperature for Storage":"-40...158 °F (-40...70 °C)","Ambient air temperature for operation":"-4...104 °F (-20...40 °C) in non-ventilated enclosure IEC 60068-2-1 and IEC 60068-2-2 -4...131 °F (-20...55 °C) IEC 60068-2-1 and IEC 60068-2-2","[Uimp] rated impulse withstand voltage":"4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$102.87","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b3b33dfc026cfe4d5d02742c44adf5d3.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/SR2PACKFU/alternatives.json"},"ai":{"faq":[{"question":"What is the clock drift and backup time?","answer":"Clock drift is 12 min/year over 32-131°F (0-55°C) and 6 s/month at 77°F (25°C). Backup time is 10 years at 77°F (25°C)."},{"question":"What compliance standards does it meet?","answer":"It meets IEC 61000-4-2 level 3, IEC 61000-4-12, IEC 61000-4-11, IEC 61000-4-3, IEC 60068-2-6 Fc, IEC 61000-4-6 level 3, IEC 60068-2-27 Ea, IEC 61000-4-5, IEC 61000-4-4 level 3, and IEC 61131-2 (pollution degree 2)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/SR2PACKFU","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/SR2PACKFU when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}