{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"SR3PACK2FU","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"SR3PACK2FU","canonicalUrl":"https://aoctrl.com/schneider/SR3PACK2FU","factsUrl":"https://aoctrl.com/api/mcp/products/SR3PACK2FU","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Zelio Logic SR3PACK2FU modular discovery pack, 26 I/O (16 DI, 10 relay DO), 100-240 V AC supply, clock with program memory check on power-up.","salesMarkdown":"Schneider Zelio Logic SR3PACK2FU is a modular discovery pack — 26 I/O total, with 16 discrete inputs (100–240 V AC, 0.6 mA) and 10 relay outputs. Supply voltage range 85–264 V AC, 50/60 Hz. Built-in clock and a program memory check on each power-up, so the controller verifies its application integrity at every start. Cycle time runs 6–90 ms, enough for discrete logic and slow sequences. Backup time 10 years at 25°C holds the real-time clock and program. Relay outputs rated for 0.1 Hz at rated load, 10 Hz no-load; mechanical durability 10 million cycles. This unit carries a suite of IEC immunity and environmental standards: IEC 61000-4-2/3/4/5/6/11/12 (ESD, radiated, fast transient, surge, conducted, voltage dips, ring wave) to Level 3 where applicable. Vibration and shock per IEC 60068-2-6 Fc and IEC 60068-2-27 Ea. IP20 on terminals, IP40 front panel.","metaTitle":"Schneider SR3PACK2FU Zelio Logic 26 I/O, 100-240V AC","metaDescription":"Active production. Zelio Logic modular discovery pack: 16 discrete inputs, 10 relay outputs, clock, program memory check on power-up. Sourced to order. RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Clock":"With","Checks":"Program memory on each power up","Category":"US1000I22378","Standards":"IEC 61000-4-5 IEC 61000-4-2 level 3 IEC 60068-2-27 Ea IEC 61000-4-3 IEC 60068-2-6 Fc IEC 61000-4-6 level 3 IEC 61000-4-11 IEC 61000-4-4 level 3 IEC 61000-4-12","Cycle time":"6...90 ms","Backup time":"10 years 77 °F (25 °C)","Clock drift":"12 min/year 32...131 °F (0...55 °C) 6 s/month 77 °F (25 °C)","Local display":"With","Response time":"50 ms ladder from state 0 to state 1)discrete input 50 ms ladder from state 1 to state 0)discrete input 50...255 ms FBD from state 0 to state 1)discrete input 50...255 ms FBD from state 1 to state 0)discrete input 10 ms from state 0 to state 1)relay output 5 ms from state 1 to state 0)relay output","Kit composition":"Cable PC SR2USB01 for connection to PC SR3B261FU","Protection Type":"Against inversion of terminals (control instructions not executed)","lifecycle_stage":"current","Pollution degree":"2 IEC 61131-2","Range of Product":"Zelio Logic","Supply frequency":"50/60 Hz","Isolation voltage":"1780 V","Number of outputs":"10 relay","Relative Humidity":"95 % without condensation or dripping water","Tightening Torque":"4.4 lbf.in (0.5 N.m)","Operating altitude":"6561.68 ft (2000 m)","Input/output number":"26","Operating rate in Hz":"0.1 Hz at Ie)relay output 10 Hz no load)relay output","Overvoltage category":"III conforming to IEC 60664-1","Discrete input number":"16","Mechanical durability":"10000000 cycles relay output","Nbr. of units in pkg.":"1","Supply voltage limits":"85...264 V","Discrete input current":"0.6 mA","Discrete input voltage":"100...240 V AC","Maximum supply current":"100 mA 100 V without extension) 50 mA 240 V without extension) 60 mA 240 V with extensions) 80 mA 100 V with extensions)","Connections - terminals":"screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 25...AWG 14) semi-solid screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 25...AWG 14) solid screw terminals, 1 x 0.25...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) solid screw terminals, 2 x 0.25...2 x 0.75 mm² AWG 24...AWG 18) flexible with cable end","IP degree of protection":"IP20 IEC 60529 terminal block) IP40 IEC 60529 front panel)","Immunity to microbreaks":"10 ms","Power consumption in VA":"12 VA without extension 17 VA with extensions","Discrete input frequency":"47...53 Hz 57...63 Hz","Product or Component Type":"Modular discovery packs","[Us] rated supply voltage":"100...240 V","Current state 0 guaranteed":"= 10 mA 12 V relay output)","Maximum altitude transport":"10000 ft (3048 m)","Voltage state 0 guaranteed":"= 0.17 mA discrete input)","Voltage state 1 guaranteed":">= 79 V discrete input","Environmental characteristic":"EMC directive IEC 61000-6-2 EMC directive IEC 61000-6-3 EMC directive IEC 61000-6-4 EMC directive IEC 61131-2 zone B low voltage directive IEC 61131-2","Disturbance radiated/conducted":"Class B EN 55022-11 group 1","Number or control scheme lines":"120 ladder 0...200 FBD","Ambient Air Temperature for Storage":"-40...158 °F (-40...70 °C)","Ambient air temperature for operation":"-4...104 °F (-20...40 °C) in non-ventilated enclosure IEC 60068-2-1 and IEC 60068-2-2 -4...131 °F (-20...55 °C) IEC 60068-2-1 and IEC 60068-2-2","[Uimp] rated impulse withstand voltage":"4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$148.59","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/3d3ec7d1911d57f1094c07e554074abb.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/SR3PACK2FU/alternatives.json"},"ai":{"faq":[{"question":"What is the listed clock feature?","answer":"The unit includes a clock (listed as 'With'.)"},{"question":"What checks does the controller perform on power-up?","answer":"It checks the program memory on each power-up."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/SR3PACK2FU","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/SR3PACK2FU when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}