{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"TA10D4S0634TPE","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"TA10D4S0634TPE","canonicalUrl":"https://aoctrl.com/schneider/TA10D4S0634TPE","factsUrl":"https://aoctrl.com/api/mcp/products/TA10D4S0634TPE","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TransferPacT automatic, automatic transfer switch, 63 A, 4P, rotary selector, PC class per IEC 60947-6-1, 400 V AC 50/60 Hz.","salesMarkdown":"The Schneider Electric TA10D4S0634TPE is an automatic transfer switch (ATS) from the TransferPacT range, designed to change the source of supply between a normal and a backup power feed — typically a mains-to-generator or mains-to-mains transfer in a low-voltage distribution board. Rated 63 A continuous at 400 V AC 50/60 Hz across 4 poles (4P), it is classed as a PC transfer switch per IEC 60947-6-1, meaning it can make, carry, and break currents under normal and overload conditions but does not provide short-circuit protection — that is left to an upstream circuit breaker. The AC-33B utilization category confirms it handles mixed resistive and motor loads up to 63 A, which covers most lighting, heating, and small motor circuits in a commercial or light industrial backup scheme. Duty is uninterrupted (continuous), so no de-rating for extended run times — the switch stays closed on the preferred source indefinitely, only opening to transfer when the controller detects a loss or restoration of supply. Short-circuit making capacity (Icm) is 15 kA peak at 400 V AC with the switch-disconnector alone, and 75 kA peak when an upstream circuit breaker coordinates — the breaker must be selected to limit let-through energy to protect the ATS. Rated short-time withstand current (Icw) is 5 kA for 0.1 s, which covers the time delay before the upstream breaker clears a fault — enough for a typical coordination study with a moulded-case breaker. Mechanical interlocking between the normal and standby contacts ensures both sources cannot be closed simultaneously, which is a safety requirement for paralleled supplies. Connection pitch is 18 mm, and both upside and downside connections are screwed terminals — expect to terminate with ring or fork lugs for the 63 A rating. Control is via a rotary knob selector switch for Auto/Manual operation, and the switch includes a padlockable OFF position for lockout/tagout.","metaTitle":"Schneider Electric TA10D4S0634TPE TransferPacT ATS, 63A 4P,","metaDescription":"Schneider Electric TA10D4S0634TPE automatic transfer switch, TransferPacT range, 63A rated current, 4 poles, 400V AC, IEC 60947-6-1. Active production. Quoted on request.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"94 mm","Width":"310 mm","title":"TA10D4S0634TPE","Height":"147 mm","Standards":"IEC 60947-6-1","Rated duty":"Uninterrupted","description":"automatic transfer switch, TransferPacT automatic, 63A, 4P, rotary, frame 100A","Control type":"Rotary knob Selector switch","Network type":"AC","Mounting mode":"Fixed","Operating mode":"Automatic Manual","lifecycle_stage":"current","Connection pitch":"18 mm","Mounting support":"Plate DIN rail","Pollution degree":"3","Range of product":"TransferPacT","Network frequency":"50/60 Hz","Poles description":"4P","Upside connection":"Screwed","Device application":"Change source of supply","Downside connection":"Screwed","Utilization category":"AC-33B","Mechanical durability":"8000 cycles","Transfer switch class":"PC","IP degree of protection":"Front face: IP40 auto mode Inside the enclosure: IP20 manual mode","Mechanical interlocking":"With mechanical interlocking","Product or component type":"Automatic transfer switch","Suitability for isolation":"Yes","Contact position indicator":"Yes","Number of contact position":"3","Locking options description":"Padlock in OFF position","Signal contacts composition":"1 NO + 2 NC 1 NC + 2 NO 2 NO","[Ui] rated insulation voltage":"Switch: 800 V Controller: 500 V","[Ie] rated operational current":"63 A","[Ue] rated operational voltage":"400 V AC 50/60 Hz","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...70 °C","[Uimp] rated impulse withstand voltage":"Switch: 6 kV Controller: 6 kV","[Icw] rated short-time withstand current":"5 kA during 0.1 s","[Icm] rated short-circuit making capacity":"15 kA switch-disconnector alone 400 V AC at 50 Hz 75 kA with upstream protection circuit breaker 400 V AC at 50 Hz","[Ith] conventional free air thermal current":"63 A at 60 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$671.73 – $1,042.08","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/0fefc1afecdcf954441901a07ede5c31.pdf","sourceUrl":"https://www.se.com/ae/en/product/TA10D4S0634TPE/automatic-transfer-switch-transferpact-automatic-63a-4p-rotary-frame-100a/"},"ai":{"faq":[{"question":"What standard does the TA10D4S0634TPE comply with?","answer":"It complies with IEC 60947-6-1 as a PC class transfer switch, with AC-33B utilization category for mixed resistive and motor loads."},{"question":"What are the mounting dimensions of this transfer switch?","answer":"Width 310 mm, height 147 mm, depth 94 mm. It mounts on a plate or DIN rail with 18 mm connection pitch."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/TA10D4S0634TPE","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/TA10D4S0634TPE when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}