{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"TM200C16R","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"TM200C16R","canonicalUrl":"https://aoctrl.com/schneider/TM200C16R","factsUrl":"https://aoctrl.com/api/mcp/products/TM200C16R","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Modicon M200 PLC controller, TM200C16R, 16 I/O relay outputs, high-speed inputs 100 kHz, DIN rail mount.","salesMarkdown":"## PLC core specs at a glance Four of the inputs can be configured as high-speed counters at 100 kHz, supporting quadrature, pulse/direction, or single-phase modes. The relay outputs carry AC-12 or DC-12 ratings at 240 V / 24 V respectively, good for 100,000 cycles of resistive loads. Communication and programming are handled via USB mini-B, RS232, or RS485 (up to 115.2 kbit/s). The built-in 24 V DC sensor supply delivers 250 mA, enough for the local input loop. Onboard memory runs 10,000 instructions, with a battery-backed real-time clock good for three years at 25 °C. Mounts on a TH35-15 or TH35-7.5 DIN rail per IEC 60715; panel mounting kit alternative. Screw terminal blocks for input, output, and serial link — removable for pre-wiring. The micro-B USB port is on the front for quick programming access. Input wiring is sink/source compatible (IEC 61131-2 type 1). Input impedance 3.3 kOhm, inrush rated at 50 A. For inductive load switching on outputs, note the minimum load requirement of 10 mA at 5 V DC to keep relay contacts clean. Response time on relay outputs is 10 ms on/off; high-speed inputs respond in 5 µs. ## Control and compliance No long lead times expected for this current line.","metaTitle":"Schneider TM200C16R Modicon M200 PLC, 16 I/O, relay outputs","metaDescription":"Schneider Electric TM200C16R PLC from Modicon M200 range, 16 I/O with relay outputs, high-speed inputs up to 100 kHz, PID control, USB/RS485. Active production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"70 mm","Width":"110 mm","Height":"90 mm","Marking":"CE","Standards":"IEC 61131-2 IEC 61010-2-201","Insulation":"Non-insulated between inputs Between output and internal logic at 1780 V AC Between output groups at 1780 V AC Between supply and internal logic at 1780 V AC Between input and internal logic at 500 V AC Between fast input and internal logic at 500 V AC Between input groups at 500 V AC","Backup time":"3 years at 25 °C (by interruption of power supply)","Clock drift":"<= 90 s/month at 25 °C","Battery type":"BR2032 Li-CFx (Lithium-Carbon Monofluoride), battery life: 5 year(s)","Minimum load":"10 mA at 5 V DC for relay output","Response time":"10 ms turn-off, Q0...Q6 terminal(s) for relay output 10 ms turn-on, Q0...Q6 terminal(s) for relay output 5 µs turn-off, I0, I1, I6, I7 terminal(s) for high speed input 5 µs turn-on, I0, I1, I6, I7 terminal(s) for high speed input 100 µs turn-off, I2...I5 terminal(s) for fast input 35 µs turn-on, I2...I5 terminal(s) for fast input 100 µs turn-off, I8 terminal(s) for regular input 35 µs turn-on, I8 terminal(s) for regular input","Inrush current":"50 A","Input impedance":"3.3 kOhm for discrete input","Memory capacity":"512 byte internal flash with 10000 instructions for backup of programs","Regulation loop":"Adjustable PID regulator up to 14 simultaneous loops","lifecycle_stage":"current","Local signalling":"1 LED (green) for PWR 1 LED (green) for RUN 1 LED (red) for module error (ERR) 1 LED (green) for SD card access (SD) 1 LED (red) for BAT 1 LED (green) for SL1 1 LED per channel (green) for I/O state","Mounting support":"Top hat type TH35-15 rail conforming to IEC 60715 Top hat type TH35-7.5 plate or panel with fixing kit conforming to IEC 60715","Pollution degree":"<= 2","Range of product":"Easy Modicon M200","Shock resistance":"15 gn for 11 ms 30 gn for 6 ms","Storage altitude":"0...3000 m","Network frequency":"50/60 Hz","Relative humidity":"10...95 %, without condensation (in operation) 10...95 %, without condensation (in storage)","Transmission rate":"1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS485 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232 12 Mbit/s for USB","Operating altitude":"0...2000 m","Control signal type":"Quadrature (x1, x2, x4) at 100 kHz for fast input (HSC mode) Pulse/direction at 100 kHz for fast input (HSC mode) Single phase at 100 kHz for fast input (HSC mode) CW/CCW at 100 kHz for fast input (HSC mode)","Discrete I/O number":"16","Sensor power supply":"24 V DC at 250 mA supplied by the controller","Switching frequency":"0.1 Hz with maximum load","Discrete input logic":"Sink or source (positive/negative) type 1 conforming to IEC 61131-2","Discrete output type":"Relay normally open","Vibration resistance":"3.5 mm at 5...8.4 Hz on symmetrical rail 1 gn at 8.4...150 Hz on symmetrical rail 3.5 mm at 5...8.7 Hz on panel mounting 2 gn at 8.7...150 Hz on panel mounting","Counting input number":"4 fast input (HSC mode) at 100 kHz 32 bits","Discrete input number":"I8: 1 regular input I2...I5: 4 fast input I0, I1, I6, I7: 4 high speed input","Electrical connection":"Mini B USB 2.0 connectorfor a programming terminal removable screw terminal blockfor inputs removable screw terminal blockfor outputs removable screw terminal block, 4 terminal(s) for connecting the serial link1 removable screw terminal block, 3 terminal(s) for connecting the 100-240 V AC power supply","Electrical durability":"100000 cycles AC-12, 240 V, 480 VA, resistive 100000 cycles DC-12, 24 V, 48 W, resistive","Mechanical durability":"20000000 cycles for relay output","Output voltage limits":"30 V DC 250 V AC","Supply voltage limits":"85...264 V","Data storage equipment":"32 GB micro SD card (optional)","Discrete input current":"7 mA for input","Discrete input voltage":"24 V","Discrete output number":"7 relay","Discrete output current":"2 A","Discrete output voltage":"24 V DC 220 V AC","IP degree of protection":"IP20 with protective cover in place","Immunity to microbreaks":"10 ms","Power consumption in VA":"51...63 VA at 100...240 V AC (with max I/O)","Exct time for event task":"60 µs response time","Product or component type":"Logic controller","[Us] rated supply voltage":"100...240 V AC","Integrated connection type":"USB port with mini B USB 2.0 connector Non isolated serial link serial 1 with terminal block connector and RS485 interface Non isolated serial link serial 2 with terminal block connector and RS232/RS485 interface Isolated serial link serial 2 with terminal block connector and RS485 interface","Voltage state 0 guaranteed":"<= 5 V for input","Voltage state 1 guaranteed":">= 15 V for input","Communication port protocol":"USB port: USB - SoMachine-Network Non isolated serial link: Modbus master/slave - RTU/ASCII or SoMachine-Network","Configurable filtering time":"0 ms for input 3 ms for input 12 ms for input","Discrete input voltage type":"DC","Electromagnetic compatibility":"Electrostatic discharge immunity test - test level: 8 kV (air discharge) conforming to IEC 61000-4-2 Electrostatic discharge immunity test - test level: 6 kV (contact discharge) conforming to IEC 61000-4-2 Susceptibility to electromagnetic fields - test level: 10 V/m (80 MHz...3 GHz) conforming to IEC 61000-4-3 Magnetic field at power frequency - test level: 30 A/m conforming to IEC 61000-4-8 Electrical fast transient/burst immunity test - test level: 2 kV (power lines) conforming to IEC 61000-4-4 Electrical fast transient/burst immunity test - test level: 2 kV (relay output) conforming to IEC 61000-4-4 Electrical fast transient/burst immunity test - test level: 1 kV (I/O) conforming to IEC 61000-4-4 Electrical fast transient/burst immunity test - test level: 1 kV (serial link) conforming to IEC 61000-4-4 1.2/50 µs shock waves immunity test - test level: 1 kV (power lines (DC)) conforming to IEC 61000-4-5 1.2/50 µs shock waves immunity test - test level: 2 kV (power lines (AC)) conforming to IEC 61000-4-5 1.2/50 µs shock waves immunity test - test level: 2 kV (relay output) conforming to IEC 61000-4-5 1.2/50 µs shock waves immunity test - test level: 1 kV (I/O) conforming to IEC 61000-4-5 1.2/50 µs shock waves immunity test - test level: 1 kV (shielded cable) conforming to IEC 61000-4-5 1.2/50 µs shock waves immunity test - test level: 0.5 kV (power lines (DC)) conforming to IEC 61000-4-5 1.2/50 µs shock waves immunity test - test level: 1 kV (power lines (AC)) conforming to IEC 61000-4-5 Conducted RF disturbances - test level: 10 V (0.15...80 MHz) conforming to IEC 61000-4-6 Conducted emission - test level: 79 dBμV/m QP/66 dBμV/m AV (power lines (AC)) conforming to IEC 55011 Conducted emission - test level: 73 dBμV/m QP/60 dBμV/m AV (power lines (AC)) conforming to IEC 55011 Radiated emission - test level: 40 dBμV/m QP class A (10 m) conforming to IEC 55011 Radiated emission - test level: 47 dBμV/m QP class A (10 m) conforming to IEC 55011 1.2/50 µs shock waves immunity test - test level: 1 kV (relay output) conforming to IEC 61000-4-5","Execution time per instruction":"0.2 µs Boolean","Execution time for 1 KInstruction":"0.3 ms for event and periodic task","Maximum current per output common":"4 A at COM 0 4 A at COM 1","Ambient air temperature for storage":"-25...70 °C","Ambient air temperature for operation":"0...55 °C (horizontal installation)","Maximum cable distance between devices":"Unshielded cable: Shielded cable: Shielded cable: Unshielded cable: <150 m for output"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$132.00","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/7e95aae822ce198a86a1f49104c1d774.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/TM200C16R/alternatives.json"},"ai":{"faq":[{"question":"What is the supply voltage requirement for the TM200C16R?","answer":"It accepts 85 to 264 V AC at 50/60 Hz."},{"question":"Does the TM200C16R have high-speed input capability?","answer":"Yes, it has four fast inputs configurable as high-speed counters (HSC) at 100 kHz, 32-bit, supporting quadrature, pulse/direction, single-phase, and CW/CCW."},{"question":"What are the physical dimensions of the TM200C16R?","answer":"Width 110 mm, height 90 mm, depth 70 mm."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/TM200C16R","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/TM200C16R when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}