{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"TM200C24R","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"TM200C24R","canonicalUrl":"https://aoctrl.com/schneider/TM200C24R","factsUrl":"https://aoctrl.com/api/mcp/products/TM200C24R","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Modicon M200 logic controller, TM200C24R, 24 discrete I/O, relay outputs, PID up to 14 loops, 100 kHz HSC.","salesMarkdown":"## I/O and high-speed functions The TM200C24R: Inputs are split into three speed tiers: four high-speed terminals (I0, I1, I6, I7) handle 5 µs response and 100 kHz HSC modes — quadrature, pulse/direction, single-phase, or CW/CCW. Four fast inputs (I2–I5) at 35 µs turn-on, and six regular inputs at 100 µs. The HSC counters are 32-bit, useful for encoder-based positioning or flow meters. Input impedance is 3.3 kΩ, and the type 1 characteristic allows both sink and source wiring — no polarity matching trouble. For process control, the controller can run up to 14 independent PID loops — adjustable, so small temperature or pressure profiles don't require a dedicated loop controller. Real-time clock drifts ≤90 s/month at 25 °C, backed by a BR2032 lithium battery rated for 5 years; program and clock retention lasts 3 years from last power-up without external power. ## Communications and programming Three ports onboard: RS232, RS485, and USB Mini-B. The serial links run at 1.2–115.2 kbps (115.2 default); RS485 bus length is 15 m, RS232 is 3 m. USB runs at 12 Mbps for fast programming download. The programming terminal connects via USB 2.0 — no special adapter needed. Removable screw terminal blocks for I/O and serial connections make wiring easy, and status LEDs cover power, run, error, SD card access, battery, and I/O state, plus one for SL1. Memory consists of 512 bytes internal flash for program backup — efficient for the typical ladder/ST application size. Firmware updates and recipes can be stored on a standard SD card. Pollution degree 2, vibration resistance up to 3.5 mm at 5–8.4 Hz on rail, shock resistance 15 gn for 11 ms. The TM200C24R is current production. Active standard catalog from Schneider Electric, available to order against RFQ.","metaTitle":"Schneider TM200C24R Modicon M200 PLC, 24 I/O Relay","metaDescription":"Current-production Modicon M200 controller with 24 discrete I/O, relay outputs, PID loops (up to 14), HSC at 100 kHz. CE, IEC 61010-2-201 compliant. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"70 mm","Width":"130 mm","Height":"90 mm","Marking":"CE","Standards":"IEC 61010-2-201 IEC 61131-2","Insulation":"Non-insulated between inputs Between output and internal logic at 1780 V AC Between output groups at 1780 V AC Between supply and internal logic at 1780 V AC Between input and internal logic at 500 V AC Between fast input and internal logic at 500 V AC Between input groups at 500 V AC","Backup time":"3 years at 25 °C (by interruption of power supply)","Clock drift":"<= 90 s/month at 25 °C","Battery type":"BR2032 Li-CFx (Lithium-Carbon Monofluoride), battery life: 5 year(s)","Minimum load":"10 mA at 5 V DC for relay output","Response time":"5 µs turn-off, I0, I1, I6, I7 terminal(s) for high speed input 5 µs turn-on, I0, I1, I6, I7 terminal(s) for high speed input 100 µs turn-off, I2...I5 terminal(s) for fast input 35 µs turn-on, I2...I5 terminal(s) for fast input 10 ms turn-off, Q0...Q9 terminal(s) for relay output 10 ms turn-on, Q0...Q9 terminal(s) for relay output 100 µs turn-off, I8...I13 terminal(s) for regular input 35 µs turn-on, I8...I13 terminal(s) for regular input","Inrush current":"50 A","Input impedance":"3.3 kOhm for discrete input","Memory capacity":"512 byte internal flash for backup of programs","Regulation loop":"Adjustable PID regulator up to 14 simultaneous loops","lifecycle_stage":"current","Local signalling":"1 LED (green) for PWR 1 LED (green) for RUN 1 LED (red) for module error (ERR) 1 LED (green) for SD card access (SD) 1 LED (red) for BAT 1 LED (green) for SL1 1 LED per channel (green) for I/O state","Mounting support":"Top hat type TH35-15 rail conforming to IEC 60715 Top hat type TH35-7.5 plate or panel with fixing kit conforming to IEC 60715","Pollution degree":"<= 2","Range of product":"Easy Modicon M200","Shock resistance":"15 gn for 11 ms 30 gn for 6 ms","Storage altitude":"0...3000 m","Network frequency":"50/60 Hz","Relative humidity":"10...95 %, without condensation (in operation) 10...95 %, without condensation (in storage)","Transmission rate":"1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS485 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232 12 Mbit/s for USB","Operating altitude":"0...2000 m","Control signal type":"Quadrature (x1, x2, x4) at 100 kHz for fast input (HSC mode) Pulse/direction at 100 kHz for fast input (HSC mode) Single phase at 100 kHz for fast input (HSC mode) CW/CCW at 100 kHz for fast input (HSC mode)","Discrete I/O number":"24","Sensor power supply":"24 V DC at 250 mA supplied by the controller","Switching frequency":"0.1 Hz with maximum load","Discrete input logic":"Sink or source (positive/negative) type 1 conforming to IEC 61131-2","Discrete output type":"Relay normally open","Vibration resistance":"3.5 mm at 5...8.4 Hz on symmetrical rail 1 gn at 8.4...150 Hz on symmetrical rail 3.5 mm at 5...8.7 Hz on panel mounting 2 gn at 8.7...150 Hz on panel mounting","Counting input number":"4 fast input (HSC mode) at 100 kHz 32 bits","Discrete input number":"I2...I5: 4 fast input I0, I1, I6, I7: 4 high speed input I8...I13: 6 regular input","Electrical connection":"Mini B USB 2.0 connectorfor a programming terminal removable screw terminal blockfor inputs removable screw terminal blockfor outputs removable screw terminal block, 4 terminal(s) for connecting the serial link1 removable screw terminal block, 3 terminal(s) for connecting the 100-240 V AC power supply","Electrical durability":"100000 cycles AC-12, 240 V, 480 VA, resistive 100000 cycles DC-12, 24 V, 48 W, resistive","Mechanical durability":"20000000 cycles for relay output","Output voltage limits":"30 V DC 250 V AC","Supply voltage limits":"85...264 V","Data storage equipment":"32 GB micro SD card (optional)","Discrete input current":"7 mA for input","Discrete input voltage":"24 V","Discrete output number":"10 relay","Discrete output current":"2 A","Discrete output voltage":"24 V DC 220 V AC","IP degree of protection":"IP20 with protective cover in place","Immunity to microbreaks":"10 ms","Power consumption in VA":"52...64 VA at 100...240 V AC (with max I/O)","Exct time for event task":"60 µs response time","Product or component type":"Logic controller","[Us] rated supply voltage":"100...240 V AC","Integrated connection type":"USB port with mini B USB 2.0 connector Non isolated serial link serial 1 with terminal block connector and RS485 interface Non isolated serial link serial 2 with terminal block connector and RS232/RS485 interface Isolated serial link serial 2 with terminal block connector and RS485 interface","Voltage state 0 guaranteed":"<= 5 V for input","Voltage state 1 guaranteed":">= 15 V for input","Communication port protocol":"USB port: USB - SoMachine-Network Non isolated serial link: Modbus master/slave - RTU/ASCII or SoMachine-Network","Configurable filtering time":"0 ms for input 3 ms for input 12 ms for input","Discrete input voltage type":"DC","Electromagnetic compatibility":"Electrostatic discharge immunity test - test level: 8 kV (air discharge) conforming to IEC 61000-4-2 Electrostatic discharge immunity test - test level: 6 kV (contact discharge) conforming to IEC 61000-4-2 Susceptibility to electromagnetic fields - test level: 10 V/m (80 MHz...3 GHz) conforming to IEC 61000-4-3 Magnetic field at power frequency - test level: 30 A/m conforming to IEC 61000-4-8 Electrical fast transient/burst immunity test - test level: 2 kV (power lines) conforming to IEC 61000-4-4 Electrical fast transient/burst immunity test - test level: 2 kV (relay output) conforming to IEC 61000-4-4 Electrical fast transient/burst immunity test - test level: 1 kV (I/O) conforming to IEC 61000-4-4 Electrical fast transient/burst immunity test - test level: 1 kV (serial link) conforming to IEC 61000-4-4 1.2/50 µs shock waves immunity test - test level: 1 kV (power lines (DC)) conforming to IEC 61000-4-5 1.2/50 µs shock waves immunity test - test level: 2 kV (power lines (AC)) conforming to IEC 61000-4-5 1.2/50 µs shock waves immunity test - test level: 2 kV (relay output) conforming to IEC 61000-4-5 1.2/50 µs shock waves immunity test - test level: 1 kV (I/O) conforming to IEC 61000-4-5 1.2/50 µs shock waves immunity test - test level: 1 kV (shielded cable) conforming to IEC 61000-4-5 1.2/50 µs shock waves immunity test - test level: 0.5 kV (power lines (DC)) conforming to IEC 61000-4-5 1.2/50 µs shock waves immunity test - test level: 1 kV (power lines (AC)) conforming to IEC 61000-4-5 Conducted RF disturbances - test level: 10 V (0.15...80 MHz) conforming to IEC 61000-4-6 Conducted emission - test level: 79 dBμV/m QP/66 dBμV/m AV (power lines (AC)) conforming to IEC 55011 Conducted emission - test level: 73 dBμV/m QP/60 dBμV/m AV (power lines (AC)) conforming to IEC 55011 Radiated emission - test level: 40 dBμV/m QP class A (10 m) conforming to IEC 55011 Radiated emission - test level: 47 dBμV/m QP class A (10 m) conforming to IEC 55011 1.2/50 µs shock waves immunity test - test level: 1 kV (relay output) conforming to IEC 61000-4-5","Execution time per instruction":"0.2 µs Boolean","Execution time for 1 KInstruction":"0.3 ms for event and periodic task","Maximum current per output common":"4 A at COM 2 4 A at COM 0 4 A at COM 1","Ambient air temperature for storage":"-25...70 °C","Ambient air temperature for operation":"0...55 °C (horizontal installation)","Maximum cable distance between devices":"Unshielded cable: Shielded cable: Shielded cable: Unshielded cable: <150 m for output"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$160.00","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/7e95aae822ce198a86a1f49104c1d774.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/TM200C24R/alternatives.json"},"ai":{"faq":[{"question":"What compliance documentation does this controller carry?","answer":"CE marked, and designed to comply with IEC 61010-2-201 and IEC 61131-2 standards."},{"question":"What is the minimum load for the relay outputs?","answer":"10 mA at 5 V DC. Ensure your load draws at least that to keep contacts clean."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/TM200C24R","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/TM200C24R when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}