{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"TM200C32R","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"TM200C32R","canonicalUrl":"https://aoctrl.com/schneider/TM200C32R","factsUrl":"https://aoctrl.com/api/mcp/products/TM200C32R","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Modicon M200 PLC, 32 I/O, relay output, 8 fast/high-speed inputs, RS232/RS485, USB programming, 100–240 VAC supply.","salesMarkdown":"## The TM200C32R – a no-nonsense 32-point M200 controller 32 discrete I/O with 4 high-speed (100 kHz) and 4 fast inputs – handles quadrature encoders, pulse trains, or simple counting without an extra module. Normally open relay outputs rated for 250 VAC or 30 VDC. Programmed via the USB Mini-B port – no special cable needed. Also carries RS232 and RS485 for HMIs, drives, or Modbus daisy chains. ## What the key timings mean for your machine cycle High-speed inputs (I0, I1, I6, I7) respond in 5 µs on/off – fine for 100 kHz single-phase or quadrature counting at 32-bit resolution. Fast inputs (I2–I5) switch in 35 µs (on) and 100 µs (off) – tight enough for registration marks or short-pulse sensors. Relay outputs cycle in 10 ms – adequate for machine sequencing; if you need faster, you'll want a solid-state expansion module. Built-in PID regulator handles up to 14 loops simultaneously – saves an external process controller for temperature or pressure. ## Power, environment, and battery – keep it simple Runs on 85–264 VAC, 50/60 Hz – global mains, no DC supply needed. Sucks about 50 A inrush on power-up, so size your breaker accordingly. Sensors get 24 VDC at 300 mA straight from the controller – no separate PSU for a handful of prox sensors or photocyes. Real-time clock backed by a BR2032 lithium battery, rated 5-year life. At 25°C, program and data hold for 3 years if mains drops. Clock drift ≤ 90 seconds per month – typical for this class, adequate for most stamp-and-log applications. Pollution degree 2 environment, vibration tolerance up to 2 gn above 8.7 Hz on panel. ## Standards and compliance – no paperwork surprises CE marked, tested to IEC 61131-2 (PLC standard) and IEC 61010-2-201 (control equipment safety). Insulation between output groups and internal logic rated at 1780 VAC. CE marked; UL and CCC not on record. Verify with project certificate if required.","metaTitle":"Schneider TM200C32R M200 PLC, 32 IO, Fast Inputs, RS485","metaDescription":"Active production TM200C32R Modicon M200 PLC: 32 discrete I/O, relay outputs, 4 high-speed/4 fast inputs to 100 kHz, USB + RS232/RS485 programming. CE, IEC 61131-2. Sourced to orde","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"Depth":"70 mm","Width":"175 mm","title":"TM200C32R","Height":"90 mm","Marking":"CE","Standards":"IEC 61131-2 IEC 61010-2-201","Insulation":"Non-insulated between inputs Between output and internal logic at 1780 V AC Between output groups at 1780 V AC Between supply and internal logic at 1780 V AC Between input and internal logic at 500 V AC Between fast input and internal logic at 500 V AC Between input groups at 500 V AC","Backup time":"3 years at 25 °C (by interruption of power supply)","Clock drift":"<= 90 s/month at 25 °C","description":"Controller M200 20I/12O relay - 220V AC","Battery type":"BR2032 Li-CFx (Lithium-Carbon Monofluoride), battery life: 5 year(s)","Minimum load":"10 mA at 5 V DC for relay output","Response time":"5 µs turn-off, I0, I1, I6, I7 terminal(s) for high speed input 5 µs turn-on, I0, I1, I6, I7 terminal(s) for high speed input 100 µs turn-off, I2...I5 terminal(s) for fast input 35 µs turn-on, I2...I5 terminal(s) for fast input 100 µs turn-off, I8...I13 terminal(s) for regular input 35 µs turn-on, I8...I13 terminal(s) for regular input 10 ms turn-off, Q0...Q15 terminal(s) for relay output 10 ms turn-on, Q0...Q15 terminal(s) for relay output 125 µs turn-off, I14...I19 terminal(s) for regular input 55 µs turn-on, I14...I19 terminal(s) for regular input","Inrush current":"50 A","Input impedance":"3.3 kOhm for discrete input","Memory capacity":"512 byte internal flash for backup of programs","Regulation loop":"Adjustable PID regulator up to 14 simultaneous loops","lifecycle_stage":"current","Local signalling":"1 LED (green) for PWR 1 LED (green) for RUN 1 LED (red) for module error (ERR) 1 LED (green) for SD card access (SD) 1 LED (red) for BAT 1 LED (green) for SL1 1 LED per channel (green) for I/O state","Mounting support":"Top hat type TH35-15 rail conforming to IEC 60715 Top hat type TH35-7.5 plate or panel with fixing kit conforming to IEC 60715","Pollution degree":"<= 2","Range of product":"Easy Modicon M200","Shock resistance":"15 gn for 11 ms 30 gn for 6 ms","Storage altitude":"0...3000 m","Network frequency":"50/60 Hz","Relative humidity":"10...95 %, without condensation (in operation) 10...95 %, without condensation (in storage)","Transmission rate":"1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS485 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232 12 Mbit/s for USB","Operating altitude":"0...2000 m","Control signal type":"Quadrature (x1, x2, x4) at 100 kHz for fast input (HSC mode) Pulse/direction at 100 kHz for fast input (HSC mode) Single phase at 100 kHz for fast input (HSC mode) CW/CCW at 100 kHz for fast input (HSC mode)","Discrete I/O number":"32","Sensor power supply":"24 V DC at 300 mA supplied by the controller","Switching frequency":"0.1 Hz with maximum load","Discrete input logic":"Sink or source (positive/negative) type 1 conforming to IEC 61131-2","Discrete output type":"Relay normally open","Vibration resistance":"3.5 mm at 5...8.4 Hz on symmetrical rail 1 gn at 8.4...150 Hz on symmetrical rail 3.5 mm at 5...8.7 Hz on panel mounting 2 gn at 8.7...150 Hz on panel mounting","Counting input number":"4 fast input (HSC mode) at 100 kHz 32 bits","Discrete input number":"I2...I5: 4 fast input I0, I1, I6, I7: 4 high speed input I8...I19: 12 regular input","Electrical connection":"Mini B USB 2.0 connectorfor a programming terminal removable screw terminal blockfor inputs removable screw terminal blockfor outputs removable screw terminal block, 4 terminal(s) for connecting the serial link1 removable screw terminal block, 3 terminal(s) for connecting the 100-240 V AC power supply","Electrical durability":"100000 cycles AC-12, 240 V, 480 VA, resistive 100000 cycles DC-12, 24 V, 48 W, resistive","Mechanical durability":"20000000 cycles for relay output","Output voltage limits":"30 V DC 250 V AC","Supply voltage limits":"85...264 V","Data storage equipment":"32 GB micro SD card (optional)","Discrete input current":"7 mA for input","Discrete input voltage":"24 V","Discrete output number":"12 relay","Discrete output current":"2 A","Discrete output voltage":"24 V DC 220 V AC","IP degree of protection":"IP20 with protective cover in place","Immunity to microbreaks":"10 ms","Power consumption in VA":"55...66 VA at 100...240 V AC (with max I/O)","Exct time for event task":"60 µs response time","Product or component type":"Logic controller","[Us] rated supply voltage":"100...240 V AC","Integrated connection type":"USB port with mini B USB 2.0 connector Non isolated serial link serial 1 with terminal block connector and RS485 interface Non isolated serial link serial 2 with terminal block connector and RS232/RS485 interface Isolated serial link serial 2 with terminal block connector and RS485 interface","Voltage state 0 guaranteed":"<= 5 V for input","Voltage state 1 guaranteed":">= 15 V for input","Communication port protocol":"USB port: USB - SoMachine-Network Non isolated serial link: Modbus master/slave - RTU/ASCII or SoMachine-Network","Configurable filtering time":"0 ms for input 3 ms for input 12 ms for input","Discrete input voltage type":"DC","Electromagnetic compatibility":"Electrostatic discharge immunity test - test level: 8 kV (air discharge) conforming to IEC 61000-4-2 Electrostatic discharge immunity test - test level: 6 kV (contact discharge) conforming to IEC 61000-4-2 Susceptibility to electromagnetic fields - test level: 10 V/m (80 MHz...3 GHz) conforming to IEC 61000-4-3 Magnetic field at power frequency - test level: 30 A/m conforming to IEC 61000-4-8 Electrical fast transient/burst immunity test - test level: 2 kV (power lines) conforming to IEC 61000-4-4 Electrical fast transient/burst immunity test - test level: 2 kV (relay output) conforming to IEC 61000-4-4 Electrical fast transient/burst immunity test - test level: 1 kV (I/O) conforming to IEC 61000-4-4 Electrical fast transient/burst immunity test - test level: 1 kV (serial link) conforming to IEC 61000-4-4 1.2/50 µs shock waves immunity test - test level: 1 kV (power lines (DC)) conforming to IEC 61000-4-5 1.2/50 µs shock waves immunity test - test level: 2 kV (power lines (AC)) conforming to IEC 61000-4-5 1.2/50 µs shock waves immunity test - test level: 2 kV (relay output) conforming to IEC 61000-4-5 1.2/50 µs shock waves immunity test - test level: 1 kV (I/O) conforming to IEC 61000-4-5 1.2/50 µs shock waves immunity test - test level: 1 kV (shielded cable) conforming to IEC 61000-4-5 1.2/50 µs shock waves immunity test - test level: 0.5 kV (power lines (DC)) conforming to IEC 61000-4-5 1.2/50 µs shock waves immunity test - test level: 1 kV (power lines (AC)) conforming to IEC 61000-4-5 Conducted RF disturbances - test level: 10 V (0.15...80 MHz) conforming to IEC 61000-4-6 Conducted emission - test level: 79 dBμV/m QP/66 dBμV/m AV (power lines (AC)) conforming to IEC 55011 Conducted emission - test level: 73 dBμV/m QP/60 dBμV/m AV (power lines (AC)) conforming to IEC 55011 Radiated emission - test level: 40 dBμV/m QP class A (10 m) conforming to IEC 55011 Radiated emission - test level: 47 dBμV/m QP class A (10 m) conforming to IEC 55011","Execution time per instruction":"0.2 µs Boolean","Execution time for 1 KInstruction":"0.3 ms for event and periodic task","Maximum current per output common":"4 A at COM 2 4 A at COM 0 4 A at COM 1","Ambient air temperature for storage":"-25...70 °C","Ambient air temperature for operation":"0...55 °C (horizontal installation)","Maximum cable distance between devices":"Unshielded cable: Shielded cable: Shielded cable: Unshielded cable: <150 m for output"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/4ce4baf821c6fcccac7342631a94b3ea.pdf","sourceUrl":"https://www.se.com/za/en/product/TM200C32R/controller-m200-20i-12o-relay-220v-ac/"},"ai":{"faq":[{"question":"What are the key dimensions of the TM200C32R?","answer":"Height 90 mm, width 175 mm, depth 70 mm. Fits standard TH35 DIN rail."},{"question":"What compliance documentation does this PLC carry?","answer":"CE marking, and it meets IEC 61131-2 and IEC 61010-2-201. No UL or CCC listed in the standard evidence."},{"question":"How many high-speed inputs does the TM200C32R have?","answer":"4 high-speed inputs (100 kHz) on I0, I1, I6, I7, and 4 fast inputs (35–100 µs) on I2–I5. The rest are regular inputs with typical 35–100 µs response."},{"question":"What communication ports does it include?","answer":"A Mini-B USB 2.0 port for programming, plus one RS232 and one RS485 serial port. Default baud rate 115.2 kbit/s; adjustable down to 1.2 kbit/s."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/TM200C32R","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/TM200C32R when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}