{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"TM262L01MESE8T","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"TM262L01MESE8T","canonicalUrl":"https://aoctrl.com/schneider/TM262L01MESE8T","factsUrl":"https://aoctrl.com/api/mcp/products/TM262L01MESE8T","rawCanonicalId":null},"summary":{"shortDescription":"logic controller, Modicon M262, 5ns per instruction, optimized Ethernet","salesMarkdown":null,"metaTitle":"TM262L01MESE8T - Schneider Electric","metaDescription":"logic controller, Modicon M262, 5ns per instruction, optimized Ethernet","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"3.5 in (90 mm)","Width":"4.9 in (125 mm)","Height":"3.9 in (100 mm)","Accuracy":"+/- 0.1 % 0.02...0.1 kHz fast output +/- 1 % 0.1...1 kHz fast output","Category":"US10MSX22533","Standards":"UL 61010-1 UL 61010-2-201 CSA C22.2 No 61010-1 CSA C22.2 No 61010-2-201 CSA C22.2 No 213 ANSI/ISA 12-12-01 IEC 61131-2","Cycle time":"0.5 ms","Insulation":"Between fast input and internal logic 550 V AC Non-insulated between inputs Between fast output and internal logic 500 V AC Non-insulated between outputs Between input and output 500 V AC Between supply and internal logic 500 V AC Non-insulated between supply and ground","Reset time":"200 ms automatic reset fast output","Backup time":"1000 h 77 °F (25 °C)","Clock drift":"<= 10 s/month 77 °F (25 °C)","Response time":"<= 1 µs turn-off, Q0...Q3 fast output","Data backed up":"1 GB built-in flash memory backup of user programs","Inrush current":"40 A","Realtime clock":"With","Input impedance":"2.81 kOhm input","Memory capacity":"32 MB program RAM 32 MB OS/website RAM 192 MB system memory RAM","Protection type":"Short-circuit and overload protection with automatic reset Reverse polarity protection Short-circuit protection","Surge withstand":"1 kV power lines (DC) common mode IEC 61000-4-5 1 kV shielded cable common mode IEC 61000-4-5 0.5 kV relay output differential mode IEC 61000-4-5 1 kV input common mode IEC 61000-4-5 1 kV transistor output common mode IEC 61000-4-5","lifecycle_stage":"current","Local signalling":"1 LED (green/red) for PWR 1 LED (green/red) for RUN 1 LED (green/red) for ERROR (fault) 1 LED (green/red) for stop forced 1 LED (green/red) for I/O error (I/O) 1 LED (green/orange) for SD card activity 1 LED (green/orange) for SL activity 1 LED (green/red) for ETH1 state 1 LED (green/red) for ETH2 state 1 LED (green/red) for EIP MS 1 LED (green/red) for EIP NS","Mounting support":"Top hat type TH35-15 rail IEC 60715 Top hat type TH35-7.5 rail IEC 60715 plate or panel with fixing kit","Pollution degree":"2","Range of Product":"Logic/motion controller - Modicon M262","Shock resistance":"15 gn 11 ms","Storage altitude":"0...9842.5 ft (0...3000 m)","Relative humidity":"10...95 %, without condensation in operation) 10...95 %, without condensation in storage)","Transmission rate":"115 kbit/s 49.2 ft (15 m) RS485 115 kbit/s 9.8 ft (3 m) RS232 480 Mbit/s 9.8 ft (3 m) USB 10/100 Mbit/s Ethernet1 10/100/1000 Mbit/s Ethernet2","Operating altitude":"0...6561.68 ft (0...2000 m)","Discrete I/O number":"8","Discrete input logic":"Sink","Discrete output type":"Transistor","Vibration resistance":"3.5 mm 2...8.4 Hz symmetrical rail 1 gn 8.4...200 Hz symmetrical rail 3.5 mm 2...8.4 Hz panel mounting 1 gn 8.4...200 Hz panel mounting","Application structure":"8 event tasks 4 cyclic master tasks 3 cyclic master tasks + 1 freewheeling task 8 external event tasks","Communication Service":"MQTTs OPC UA server (Encrypt) HTTPs Methods (API) Web server Web visu TLS 1.2 TLS 1.3 SNTP NTP client/server FTP client/server FTPs server SQL client (remote access) DHCP client DHCP server DNS client POP3s client SMTP client SNMP client/server","Discrete input number":"4, discrete input fast input IEC 61131-2 Type 1","Discrete output logic":"Source","Electrical connection":"removable spring terminal block for inputs and outputs removable spring terminal block for connecting the 24 V DC power supply","Maximum tungsten load":"<1.5 W","Nbr. of units in pkg.":"1","Output voltage limits":"30 V DC","PLC Power Consumption":"82 W","Positioning functions":"Libraries axes coordinated","Supply voltage limits":"20.4...28.8 V DC","Upstream connectivity":"IIoT-ready machine to cloud Connected machine to plant","Data storage equipment":"<= 32 GB SDHC card optional)","Discrete input current":"7.5 mA fast input","Discrete input voltage":"24 V","Discrete output number":"4 transistor fast output","Overvoltage protection":"With","Discrete output current":"0.5 A fast output Q0...Q3)","Discrete output voltage":"24 V DC","IP degree of protection":"IP20","Immunity to microbreaks":"0.01 ms","Maximum leakage current":"10 µA output","Electromagnetic emission":"Conducted emissions 120...69 dBµV/m QP power lines)10...150 kHz IEC 55011 Conducted emissions 63 dBμV/m QP power lines)1.5...30 MHz IEC 55011 Radiated emissions 40 dBµV/m30...230 kHz IEC 55011 Conducted emissions 79...63 dBμV/m QP power lines)150...1500 kHz IEC 55011 Radiated emissions230...1000 MHz IEC 55011","Maximum output frequency":"300 kHz","Product or Component Type":"Logic controller","[Us] rated supply voltage":"24 V DC - 15...20 %","Integrated connection type":"Ethernet 1 RJ45 10/100BASE-T Ethernet 2 2 RJ45 100/1000BASE-T Serial link RJ45 RS232/RS485 Smart communication bus (TMSCO1 only) TM3 IO bus USB type mini B","Voltage state 0 guaranteed":"<= 5 V DC","Voltage state 1 guaranteed":">= 15 V DC","Communication port protocol":"EtherNet/IP adapter EtherNet/IP scanner Modbus TCP client/server Modbus TCP IO scanner Modbus TCP NVL Ethernet RSTP Modbus SL client/server Modbus SL IO scanner Modbus SL modem management Machine Expert ASCII manager ASCII modem management","Configurable filtering time":"0.001 ms fast input 0.002 ms fast input 0.005 ms fast input 0.01 ms fast input 0.05 ms fast input 0.1 ms fast input 0.5 ms fast input 1 ms fast input 4 ms fast input 12 ms fast input","Discrete input voltage type":"DC","Resistance to fast transients":"2 kV IEC 61000-4-4 power lines) 1 kV IEC 61000-4-4 Ethernet line) 1 kV IEC 61000-4-4 serial link) 1 kV IEC 61000-4-4 input) 1 kV IEC 61000-4-4 transistor output)","Execution time for 1 KInstruction":"0.005 ms","Maximum current per output common":"0.5 A Q0...Q3 fast output","Ambient Air Temperature for Storage":"-40...185 °F (-40...85 °C)","Maximum Number of Connected Devices":"EtherNet/IP: 64 Modbus TCP: 64 Modbus TCP/EtherNet/IP: 96","Resistance to conducted disturbances":"10 V 0.15...80 MHz IEC 61000-4-4 3 V 0.1...80 MHz 10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz)","Resistance to electromagnetic fields":"9.1 V/m (10 V/m) 80 MHz...1 GHz IEC 61000-4-3 2.7 V/m (3 V/m) 1.4 GHz...2 GHz IEC 61000-4-3 0.9 V/m (1 V/m) 2 GHz...3 GHz IEC 61000-4-3","Ambient air temperature for operation":"-4...140 °F (-20...60 °C) horizontal installation) -4...122 °F (-20...50 °C) vertical installation) -4...113 °F (-20...45 °C) flat mounting)","Resistance to electrostatic discharge":"4 kV on contact IEC 61000-4-2 8 kV on air IEC 61000-4-2","Maximum cable distance between devices":"Shielded cable Shielded cable Unshielded cable Unshielded cable Shielded cable Shielded cable <49.2 ft (15 m) RS232"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$1,301.86","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2638acbb91b605865126baed327c8a70.pdf","sourceUrl":"https://www.se.com/ca/en/product/TM262L01MESE8T/logic-controller-modicon-m262-5ns-per-instruction-optimized-ethernet/","alternativesUrl":"https://aoctrl.com/api/mcp/products/TM262L01MESE8T/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/TM262L01MESE8T","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/TM262L01MESE8T when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}