{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"TM310M45ECT26T","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"TM310M45ECT26T","canonicalUrl":"https://aoctrl.com/schneider/TM310M45ECT26T","factsUrl":"https://aoctrl.com/api/mcp/products/TM310M45ECT26T","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Modicon M310 motion controller, TM310M45ECT26T, 24 discrete I/O, 0.5 ms cycle, fast I/O <2.5 µs, dual Ethernet, EtherCAT, CANopen, RS232/485, 210 x 114 x 70 mm.","salesMarkdown":"The TM310M45ECT26T: It reads incremental encoders and a master encoder directly, and communicates over dual gigabit Ethernet ports, EtherCAT, CANopen master, Modbus TCP, Ethernet/IP, OPC UA, and RS232/485. Built-in 2 GB program RAM and 16 GB flash for data logging or recipe storage – the real-time clock holds the time for 6 years at 25 °C. All this draws 20 W from a 24 V DC supply. The controller measures 210 x 114 x 70 mm and mounts on TH35-15 DIN rail or panel. Vibration resistance: 1 gn above 8.4 Hz on DIN rail, shock 15 gn for 11 ms; humidity 5–95% non-condensing, pollution degree 2. ## I/O and field wiring Inputs are sink or source (24 V DC, 5.2 mA per fast input), compliant with IEC 61131-2 Type 1. Outputs are source transistor, short-circuit and automatic overload protected, with reverse polarity protection on the supply. Insulation between fast input and internal logic is 550 V AC; between fast output and logic is 500 V AC; but inputs are non-insulated from each other. Surge withstand 0.5 kV common and differential mode on the DC power lines per IEC 61000-4-5. The removable terminal block arrangement keeps the encoder and serial connections separate from the main I/O – helps section the wiring. ## Lifecycle and sourcing note This part is actively produced – no end-of-life notice in the record. It's a standard catalog item (Modicon M310 range), so you can spec it into a BOM without worrying about a last-time buy. If you need to source it, quote against an RFQ for the best lead time.","metaTitle":"Schneider TM310M45ECT26T Modicon M310 Motion Controller, 24","metaDescription":"TM310M45ECT26T – Current-production Modicon M310 motion controller with 24 I/O, 0.5 ms cycle, fast I/O <2.5 µs. Dual Ethernet, EtherCAT, CANopen, RS232/485. Active, order to BOM.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["PLC Communication Modules"],"specifications":{"Depth":"70 mm","Width":"210 mm","Height":"114 mm","Standards":"IEC 61131-2","Cycle time":"0.5 ms","Insulation":"Between fast input and internal logic at 550 V AC Non-insulated between inputs Between fast output and internal logic at 500 V AC Non-insulated between outputs Between input and output at 500 V AC Between supply and internal logic at 500 V AC Between power output and ground at 500 V AC","Backup time":"6 years time and program saving at 25 °C","Clock drift":"< 30 s/month at 25 °C","Encoder type":"1 master encoder 2 incremental encoders","Response time":"< 2.5 µs turn-on, I0...I17 terminal(s) for fast input < 2.5 µs turn-off, I0...I17 terminal(s) for fast input <= 1 µs turn-off, Q0...Q7 terminal(s) for fast output","Data backed up":"16 GB built-in flash memory for backup of application and data","Realtime clock":"With","Input impedance":"4.3 kOhm for input","Memory capacity":"2 GB for for the program and the firmware RAM DDR3 128 kB for file storage RAM","Protection type":"Short-circuit and automatic overload protection Reverse polarity protection","Surge withstand":"0.5 kV power lines (DC) common mode conforming to IEC 61000-4-5 0.5 kV power lines (DC) differential mode conforming to IEC 61000-4-5","lifecycle_stage":"current","Local signalling":"1 LED (green) for PWR 1 LED (red) for ERR 1 LED (green) for RUN 1 LED (green) for SYS 1 LED (green) for ECT 1 LED (green/red) for CANopen bus status 1 LED (green) for ETH1 state 1 LED (green) for ETH2 state 1 LED (green) for SL1 1 LED (green) for SL2 1 LED (green) for USB pendrive download status","Mounting support":"Top hat type TH35-15 rail conforming to IEC 60715 plate or panel with fixing kit","Pollution degree":"2","Range of product":"Modicon M310","Shock resistance":"15 gn for 11 ms","Storage altitude":"0...3000 m","Relative humidity":"5...95 %, without condensation (in operation) 5...95 %, without condensation (in storage)","Transmission rate":"9600...115200 bauds for bus length of 30 m for RS485 9600...115200 bauds for bus length of 10 m for RS232 1 Mbps for bus length of 20 m for CANopen 10/100/1000 Mbps for bus length of 100 m for Ethernet1 10/100/1000 Mbps for bus length of 100 m for Ethernet2 100 Mbps for bus length of 100 m for EtherCAT","Operating altitude":"0...2000 m","Discrete I/O number":"24","Discrete input logic":"Sink or source","Discrete output type":"Transistor","Vibration resistance":"3.5 mm at 5...8.4 Hz on direct mounting on DIN rail 1 gn at 8.4...150 Hz on direct mounting on DIN rail 7 mm at 5...8.4 Hz on panel mounting 1 gn at 8.4...150 Hz on panel mounting","Application structure":"8 event tasks 8 cyclic master tasks 8 external event tasks","Communication service":"Modbus TCP client/server OPC UA server OPC UA client Ethernet/IP adapter Ethernet/IP scanner TLS 1.2 TLS 1.3 CANopen master","Discrete input number":"18, NPN or PNP 4 fast input (counter mode) conforming to IEC 61131-2 Type 1 6 touch probe input conforming to IEC 61131-2 Type 1 8 fast input conforming to IEC 61131-2 Type 1","Discrete output logic":"Source","Electrical connection":"removable terminal blockfor inputs and outputs removable terminal blockfor connecting the 24 V DC power supply removable terminal blockfor connecting incremental or absolute encoder removable terminal blockfor connecting the serial link1","PLC Power Consumption":"20 W","Positioning functions":"Libraries axes synchronous function Homing function Jog function CST function CSP function CSV function","Upstream connectivity":"Connected machine to plant","Discrete input current":"5.2 mA for fast input","Discrete input voltage":"24 V","Discrete output number":"8 transistor fast output","Overvoltage protection":"Without","Discrete output current":"0.1 A for fast output (Q0...Q7)","Discrete output voltage":"24 V DC","IP degree of protection":"IP20","Immunity to microbreaks":"0.01 ms","Maximum leakage current":"0.01 mA for output","Electromagnetic emission":"Radiated emissions - test level: 40 dBμV/m QP at 30...230 kHz conforming to IEC 61000-6-4 Radiated emissions - test level: 47 dBμV/m QP at 230...1000 MHz conforming to IEC 61000-6-4","Product or component type":"Motion controller","[Us] rated supply voltage":"24 V DC - 10...10 %","Integrated connection type":"Ethernet 1 with RJ45 connector and 10 BASE-T/100 BASE-TX/1000 BASE-T interface Ethernet 2 with RJ45 connector and 10 BASE-T/100 BASE-TX/1000 BASE-T interface CANopen CANopen with 1 male SUB-D 9 connector and DB9 connector interface USB type A with USB connector and DB9 connector interface RS232 serial 1 with 1 male SUB-D 9 connector and DB9 connector interface RS485 serial 2 with 1 removable 4-way screw connector connector and DB9 connector interface 1 encoder ENC with 1 male SUB-D 9 connector and DB9 connector interface 1 encoder ENC with 1 removable 3-way screw connector connector EtherCAT ECT with RJ45 connector and 100BASE-FX or 10/100BASE-T interface","Voltage state 0 guaranteed":"0...5 V for DC","Voltage state 1 guaranteed":"17...30 V for DC","Communication port protocol":"EtherNet/IP adapter EtherNet/IP scanner Modbus TCP client/server Modbus RTU master/slave Modbus ASCII master CANopen master EtherCAT master","Discrete input voltage type":"DC","Resistance to fast transients":"2 kV (power lines) conforming to IEC 61000-4-4 1 kV (communication circuit) conforming to IEC 61000-4-4 1 kV (digital I/O) conforming to IEC 61000-4-4","Execution time for 1 KInstruction":"3.3 µs","Maximum current per output common":"0.1 A with Q0...Q7 for fast output","Ambient air temperature for storage":"-20...70 °C","Maximum number of connected devices":"EtherNet/IP: 64 Modbus TCP: 63 CANopen: 63 EtherCAT: 64 Modbus RTU and ASCII: 32","Resistance to electromagnetic fields":"10 V/m 80 MHz...1 GHz conforming to IEC 61000-4-3 3 V/m 1.4 GHz...2 GHz conforming to IEC 61000-4-3 1 V/m 2 GHz...3 GHz conforming to IEC 61000-4-3","Ambient air temperature for operation":"0...55 °C (horizontal installation) 0...45 °C (vertical installation)","Resistance to electrostatic discharge":"4 kV on contact conforming to IEC 61000-4-2 8 kV on air conforming to IEC 61000-4-2","Maximum cable distance between devices":"Shielded cable: Shielded cable: Shielded twisted pair: Shielded twisted pair: Shielded twisted pair: Shielded twisted pair: Shielded cable: <100 m for ETHERNET"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/TM310M45ECT26T/ethercat-motion-controller-modicon-m310-32-axis-0-5ms-ethercat-ethernet-serial-lines-canopen-encoder-18di-8do/","alternativesUrl":"https://aoctrl.com/api/mcp/products/TM310M45ECT26T/alternatives.json"},"ai":{"faq":[{"question":"What are the key dimensions of TM310M45ECT26T?","answer":"Width 210 mm, height 114 mm, depth 70 mm. It mounts on TH35-15 DIN rail or a panel with the fixing kit."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/TM310M45ECT26T","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/TM310M45ECT26T when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}