{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"TM3XFHSC202","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"TM3XFHSC202","canonicalUrl":"https://aoctrl.com/schneider/TM3XFHSC202","factsUrl":"https://aoctrl.com/api/mcp/products/TM3XFHSC202","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Modicon TM3 high-speed counting module, TM3XFHSC202, 10 inputs 8 outputs, 200 kHz, automatic reset, 24 V DC.","salesMarkdown":"The TM3XFHSC202: 200 kHz counting on this Modicon TM3 slice means it tracks encoder pulses or fast proximity switches without losing edges. Ten inputs configurable as sink or source, eight source outputs each rated 300 mA. Automatic reset simplifies recovery after a fault condition. Draws 100 mA from the 5 V backplane and 50 mA from the 24 V external supply. IP20 with protective cover, rated for vibration 3.5 mm at 2–8.4 Hz and shock 15 gn for 11 ms. ## Counting modes and event handling Supports one-shot, modulo, and event counting, plus frequency and period measurement. Two main expert functions handle the high-speed channels; up to eight simple functions run concurrently. Event thresholds fire in under 10 µs, letting the PLC latch fast edge transitions without additional input conditioners.","metaTitle":"Schneider TM3XFHSC202 HSC Module, 200 kHz","metaDescription":"Active production. 10 inputs / 8 outputs, 200 kHz counting, automatic reset, 24 V DC. Sourced to order. UL/CSA/IEC 61131-2 compliant.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"3.3 in (85 mm)","Reset":"Automatic reset","Width":"1.5 in (39 mm)","Height":"3.5 in (90 mm)","Category":"US10MSX22533","Services":"HSC simple One shot/Modulo HSC main single phase One shot/Modulo/Event counting HSC main dual phase Modulo/Free-large Period meter Edge to Edge, Edge to Opposite","Standards":"CSA C22.2 No 142 ANSI/ISA 12-12-01 UL 1604 CSA C22.2 No 213 EN/IEC 61131-2:2007 UL 508","Counting mode":"2 main expert function (main counting function, frequency meter, period meter) Max 8 simple counting function","Output voltage":"24 V DC transistor output","lifecycle_stage":"current","Event management":"8 maximum per PLC Thresholds < 10 µs","Local signalling":"1 LED I/O 1 LED RUN 1 LED ERR","Mounting support":"Top hat type TH35-15 rail IEC 60715 Top hat type TH35-7.5 rail IEC 60715 plate or panel with fixing kit","Pollution degree":"2","Range of Product":"Modicon TM3","Shock resistance":"15 gn 11 ms","Storage altitude":"0...9842.5 ft (0...3000 m)","DC supply voltage":"24 V","Relative humidity":"10...95 %, without condensation in operation) 10...95 %, without condensation in storage)","Counting frequency":"200 kHz","Operating altitude":"0...6561.68 ft (0...2000 m)","Current consumption":"100 mA 5 V DC 50 mA 24 V DC","Discrete I/O number":"18","Discrete input logic":"Sink or source","Vibration resistance":"3.5 mm 2...8.4 Hz DIN rail 1 gn 8.4...200 Hz DIN rail 3.5 mm 2...8.4 Hz panel 1 gn 8.4...200 Hz panel","Discrete output logic":"Source","Nbr. of units in pkg.":"1","Output voltage limits":"30 V DC","Discrete input voltage":"24 V DC","Output protection type":"Against overload and short-circuits","Discrete output current":"300 mA fast output Q0...Q7)","Electrical circuit type":"Standard input Latch input","IP degree of protection":"IP20 with protective cover in place","Electromagnetic emission":"Conducted emissions 120...69 dBµV/m QP10...150 kHz EN/IEC 55011 Conducted emissions 63 dBμV/m QP1.5...30 MHz EN/IEC 55011 Radiated emissions 40 dBµV/m class A30...230 MHz EN/IEC 55011 Conducted emissions 79...63 dBμV/m QP150...1500 kHz EN/IEC 55011 Radiated emissions 47 dBµV/m class A230...1000 MHz EN/IEC 55011","Number of input channels":"10","Number of output channels":"8","Product or Component Type":"Module hight speed counting","[Us] rated supply voltage":"24 V DC external supply - 15...20 %)","Resistance to fast transients":"2 kV alimentation cableEN/IEC 61000-4-4 1 kV Ethernet lineEN/IEC 61000-4-4 1 kV serial linkEN/IEC 61000-4-4 1 kV inputEN/IEC 61000-4-4 1 kV transistor outputEN/IEC 61000-4-4","Ambient Air Temperature for Storage":"-40...185 °F (-40...85 °C)","Resistance to conducted disturbances":"10 V 0.15...80 MHz EN/IEC 61000-4-4","Resistance to electromagnetic fields":"9.1 V/m (10 V/m) 80 MHz...1 GHz EN/IEC 61000-4-3 2.7 V/m (3 V/m) 1.4 GHz...2 GHz EN/IEC 61000-4-3 0.9 V/m (1 V/m) 2 GHz...3 GHz EN/IEC 61000-4-3","Ambient Air Temperature for Operation":"-4...140 °F (-20...60 °C) horizontal installation -4...122 °F (-20...50 °C) vertical installation","Resistance to electrostatic discharge":"8 kV in air EN/IEC 61000-4-2 4 kV on contact EN/IEC 61000-4-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$480.27 – $1,079.34","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/9e07aa7bae77c22c18ea75de0faa9bd7.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/TM3XFHSC202/alternatives.json"},"ai":{"faq":[{"question":"What is TM3XFHSC202's listed depth?","answer":"85 mm (3.3 in)."},{"question":"What is its listed reset?","answer":"Automatic reset after a fault or counting overflow condition."},{"question":"What compliance documentation does this module carry?","answer":"It is certified to UL 508, CSA C22.2 No 142, and EN/IEC 61131-2:2007."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/TM3XFHSC202","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/TM3XFHSC202 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}