{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"TM3XTYS4","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"TM3XTYS4","canonicalUrl":"https://aoctrl.com/schneider/TM3XTYS4","factsUrl":"https://aoctrl.com/api/mcp/products/TM3XTYS4","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Modicon TM3 TM3XTYS4 Parallel Interface Module for TeSys U, 12 Input 8 Output, 24 V DC, Automatic Reset.","salesMarkdown":"## TM3XTYS4 – Parallel interface for TeSys U motor starters Schneider Modicon TM3 TM3XTYS4 is a parallel interface module that sits between a controller and up to eight TeSys U motor starters. It strips the I/O mapping down to 12 inputs and 8 transistor outputs, all switched at 24 V DC. The RJ45 connectors carry the start/stop and feedback signals for each starter, while a removable screw terminal block handles the 24 V DC supply. Response time through the module is under 10 ms on both turn-on and turn-off edges, so it keeps cycle times tight for packaging or conveyor cell sequencing. Each output channel delivers 300 mA continuously (800 mA for the first 100 ms), enough to energise a small relay or indicator per starter. ## Installation and mounting considerations The module clips onto a TH35-15 or TH35-7.5 DIN rail, or it can be panel-mounted with a fixing kit. At 90 mm tall, 30 mm wide, and 85 mm deep, it fits a compact cabinet footprint. The four RJ45 connectors face outward, so plan for cable bend radius and access to the screw terminal block on the other side. Wire the 24 V DC supply to the removable terminal block (3 x 2.5 mm²). The module draws 5 mA at 5 V DC on the backplane when on and up to 1200 mA from the external 24 V supply; automatic reset re-energises outputs after a fault clears.","metaTitle":"TM3XTYS4 Modicon TM3 Parallel Interface Module, 12 Input 8 O","metaDescription":"Active Schneider Modicon TM3 TM3XTYS4 parallel interface for TeSys U. 12 inputs, 8 outputs, 24 V DC, automatic reset. RFQ for current production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Unclassified"],"specifications":{"Depth":"3.3 in (85 mm)","Reset":"Automatic reset","Width":"1.2 in (30 mm)","Height":"3.5 in (90 mm)","Marking":"CE","Category":"US10MSX22533","Insulation":"Between the RJ45 connectors and internal logic 500 V AC Non-insulated between RJ45 connectors","Response time":"< 10 ms turn-on input < 10 ms turn-off input","Output voltage":"24 V DC transistor output","Surge withstand":"1 kV input common mode EN/IEC 61000-4-5 1 kV output common mode EN/IEC 61000-4-5","lifecycle_stage":"current","Local signalling":"3 LEDs green per channel input status 2 LEDs green per channel output status","Mounting support":"Top hat type TH35-15 rail IEC 60715 Top hat type TH35-7.5 rail IEC 60715 plate or panel with fixing kit","Pollution degree":"2","Range of Product":"Modicon TM3","Shock resistance":"15 gn 11 ms","Storage altitude":"0...9842.5 ft (0...3000 m)","DC supply voltage":"24 V","Relative humidity":"10...95 %, without condensation in operation) 10...95 %, without condensation in storage)","Operating altitude":"0...6561.68 ft (0...2000 m)","Current consumption":"5 mA 5 V DC via bus connector at state on 35 mA 5 V DC via bus connector at state off 0 mA 24 V DC via bus connector at state on 10 mA 24 V DC via bus connector at state off 1200 mA 24 V DC external power supply at state on","Input current limits":"5 mA per input","Input voltage limits":"19.2...28.8 V per input","Maximum load current":"800 mA per channel starting mode 100 ms 300 mA per channel normal mode","Vibration resistance":"3.5 mm 5...8.4 Hz DIN rail 3 gn 8.4...150 Hz DIN rail 3.5 mm 5...8.4 Hz panel 3 gn 8.4...150 Hz panel","Electrical connection":"3 x 2.5 mm² removable screw terminal block with pitch 5.08 mm adjustment for connecting the 24 V DC power supply 4 RJ45 connectors for connecting the motor starters","Nbr. of units in pkg.":"1","Output protection type":"Against overload, protection technology: current limiter","IP Degree of Protection":"IP20","IP degree of protection":"IP20 with protective cover in place","Electromagnetic emission":"Radiated emissions 40 dBμV/m QP class A 10 m)30...230 MHz EN/IEC 55011 Radiated emissions 47 dBμV/m QP class A 10 m)230...1000 MHz EN/IEC 55011","Number of input channels":"12","Number of output channels":"8","Product or Component Type":"Parallel interface module","[Us] rated supply voltage":"24 V DC external supply - 15...20 %)","Product Specific Application":"TeSys U","Resistance to fast transients":"1 kV inputEN/IEC 61000-4-4 1 kV outputEN/IEC 61000-4-4","Resistance to magnetic fields":"98.4 A/m (30 A/m) 50/60 Hz EN/IEC 61000-4-8","Ambient Air Temperature for Storage":"-13...158 °F (-25...70 °C)","Resistance to conducted disturbances":"10 V 0.15...80 MHz EN/IEC 61000-4-6 3 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) Marine specification (LR, ABS, DNV, GL)","Resistance to electromagnetic fields":"9.1 V/m (10 V/m) 80 MHz...1 GHz EN/IEC 61000-4-3 2.7 V/m (3 V/m) 1.4 GHz...2 GHz EN/IEC 61000-4-3 0.9 V/m (1 V/m) 2 GHz...3 GHz EN/IEC 61000-4-3","Ambient Air Temperature for Operation":"14...95 °F (-10...35 °C) vertical installation 14...131 °F (-10...55 °C) horizontal installation","Resistance to electrostatic discharge":"8 kV in air EN/IEC 61000-4-2 4 kV on contact EN/IEC 61000-4-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$82.55 – $195.44","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/4e9a8aef9bc65bf44e21f92b01d3d4d5.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/TM3XTYS4/alternatives.json"},"ai":{"faq":[{"question":"What is the depth of the TM3XTYS4?","answer":"The module depth is 3.3 inches (85 mm)."},{"question":"What compliance markings does the TM3XTYS4 carry?","answer":"It carries a CE marking. EMC test data for conducted and radiated emissions is available (EN/IEC 55011 Class A)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/TM3XTYS4","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/TM3XTYS4 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}