{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"TM5CSLC300FS","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"TM5CSLC300FS","canonicalUrl":"https://aoctrl.com/schneider/TM5CSLC300FS","factsUrl":"https://aoctrl.com/api/mcp/products/TM5CSLC300FS","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Modicon TM5 Safety Logic Controller, TM5CSLC300FS, SERCOS III interface, SIL 3/PL e, supports 20 safety nodes, 4.3 W, 75 × 62.5 × 99 mm.","salesMarkdown":"## Safety logic CPU for distributed SERCOS III rings The TM5CSLC300FS is the safe logic controller within the Modicon TM5 range, handling safety-oriented control over a SERCOS III ring at 100 Mbit/s full duplex. It supports up to 20 safety nodes, each communicating on the same fiber ring, with a maximum cable distance of 100 m between stations. Rated SIL 3 per IEC 61508 and IEC 62061, PL e category 4 per ISO 13849-1. The safety reliability data shows PFD < 1E-5, PFH < 1E-9, and MTTFd > 100 years, which covers the typical demands for high-risk process and machinery safety loops. The controller draws 4.3 W from the backplane, runs fanless, and is IP20-rated. It mounts in a standard TM5 bus assembly; its envelope measures 75 mm deep, 62.5 mm wide, and 99 mm high. ## Integration and environmental limits Two shielded RJ45 ports are provided for the SERCOS III ring in and out; a memory key slot for configuration backup sits on the front face. Local diagnostics include six LEDs covering application run, debug mode, authorization, configuration, firmware, boot status, and memory key status. Operating temperature: 0 to 55 °C when mounted horizontally, 0 to 45 °C for vertical installation. Relative humidity 5 to 95% non-condensing. Maximum altitude 2000 m. Input protection is via a non-replaceable integrated fuse; reverse polarity protection is included. The controller complies with CE, EN 13849-1, IEC 61131-2, IEC 61508, IEC 61511, and IEC 62061.","metaTitle":"Schneider TM5CSLC300FS Safety Logic Controller, SIL 3, PL e,","metaDescription":"Active Modicon TM5 safety CPU with SERCOS III, supports 20 safety nodes, SIL 3/PL e, 4.3 W, 75×62.5×99 mm. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["PLC Communication Modules"],"specifications":{"Depth":"3.0 in (75 mm)","Width":"2.5 in (62.5 mm)","title":"TM5CSLC300FS","Colour":"Red","Height":"3.9 in (99 mm)","Marking":"CE","Standards":"EN 13849-1 IEC 61131-2 IEC 61508 IEC 61511 IEC 62061","Cycle time":"1 ms","description":"Controller system, Modicon TM5 Safety, Safe logic CPU, SERCOS III interface, 20 nodes","Safety level":"SIL 3 IEC 61508 SIL 3 IEC 62061 PL = e ISO 13849-1 category 4","Rated voltage":"24 V -15...20 %","Realtime clock":"With non-volatile memory","Type of cooling":"Fanless","lifecycle_stage":"current","Local signalling":"1 LED (green or orange) for application run or machine expert - safety debug mode 1 LED (green) for authorization status 1 LED (orange) for configuration status (Ready) 1 LED (orange) for firmware status 1 LED (red) for boot status / FS status 1 LED (orange) for memory key status","Range of product":"Modicon TM5","Number of devices":"2 shielded RJ45 1 memory key slot","Relative humidity":"5...95 % without condensation","Transmission rate":"100 Mbit/s for full duplex","Device application":"Safety logic controller","Function available":"Support max 20 safety nodes","Operating altitude":"0...2000 m","Input protection type":"Integrated fuse (not interchangeable)","Power consumption in W":"4.3 W","IP degree of protection":"IP20","Safety reliability data":"PFD < 1E-5 PFH < 1E-9 MTTFd > 100 years","Product or component type":"Controller system","Communication network type":"SERCOS III Ethernet)","Reverse polarity protection":"Yes","Ambient air temperature for storage":"-13...158 °F (-25...70 °C)","Ambient air temperature for operation":"32...113 °F (0...45 °C) vertical installation) 32...131 °F (0...55 °C) horizontal installation)","Maximum cable distance between devices":"328.08 ft (100 m) between station"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/8acb2d13723dfb01c2540985b179ce2d.pdf","sourceUrl":"https://www.se.com/ca/en/product/TM5CSLC300FS/controller-system-modicon-tm5-safety-safe-logic-cpu-sercos-iii-interface-20-nodes/"},"ai":{"faq":[{"question":"What compliance standards does the TM5CSLC300FS meet?","answer":"It carries CE marking and complies with EN 13849-1, IEC 61131-2, IEC 61508, IEC 61511, and IEC 62061. The safety level is SIL 3 per IEC 61508/62061 and PL e category 4 per ISO 13849-1."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/TM5CSLC300FS","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/TM5CSLC300FS when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}