{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"TM5SDI2DF","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"TM5SDI2DF","canonicalUrl":"https://aoctrl.com/schneider/TM5SDI2DF","factsUrl":"https://aoctrl.com/api/mcp/products/TM5SDI2DF","rawCanonicalId":null},"summary":{"shortDescription":"COUNTER MODULE, MODICON TM5, 2I,","salesMarkdown":null,"metaTitle":"TM5SDI2DF - Schneider Electric","metaDescription":"COUNTER MODULE, MODICON TM5, 2I,","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"3.0 in (75 mm)","Width":"0.5 in (12.5 mm)","Height":"3.9 in (99 mm)","Marking":"CE","Category":"US1PC1222532","Isolation":"500 Vrms AC insulation between channel and bus No insulation between channels","Standards":"UL 508 CSA C22.2 No 213 CSA C22.2 No 142 IEC 61131-2","Input filtering":"<= 25 ms configurable by software","Surge withstand":"0.5 kV differential mode IEC 61000-4-5 1 kV common mode IEC 61000-4-5","lifecycle_stage":"current","Pollution degree":"2 IEC 60664","Range of Product":"Modicon TM5","Shock resistance":"15 gn 11 ms","Storage altitude":"0...9842.5 ft (0...3000 m)","DC supply voltage":"24 V","Relative humidity":"5...95 % without condensation","Counting frequency":"50 kHz","Function of module":"Interval measurement Event counting","Operating altitude":"0...6561.68 ft (0...2000 m)","Current consumption":"30 mA 5 V DC bus 34 mA 24 V DC input/output","Discrete input logic":"Sink","Vibration resistance":"1 gn 8.4...150 Hz DIN rail 3.5 mm 5...8.4 Hz DIN rail","Discrete input number":"2","Nbr. of units in pkg.":"1","Discrete input current":"10.5 mA 24 V","Discrete input voltage":"24 V DC","IP Degree of Protection":"IP20","IP degree of protection":"IP20IEC 61131-2","Product or Component Type":"Counter module","Product Specific Application":"Frequency meter Period measurement Frequency generator Upcounting Downcounting","Electromagnetic compatibility":"EN/IEC 61000-4-6","Resistance to fast transients":"1 kV IEC 61000-4-4 I/O) 1 kV IEC 61000-4-4 shielded cable) 2 kV IEC 61000-4-4 power lines)","Disturbance radiated/conducted":"CISPR 11","Maximum power dissipation in W":"0.97 W","Ambient Air Temperature for Storage":"-13...158 °F (-25...70 °C)","Resistance to electromagnetic fields":"0.9 V/m (1 V/m) 2...2.7 GHz IEC 61000-4-3 9.1 V/m (10 V/m) 80...2000 MHz IEC 61000-4-3","Ambient air temperature for operation":"32...131 °F (0...55 °C) without derating horizontal installation) 32...140 °F (0...60 °C) with derating factor horizontal installation) 32...122 °F (0...50 °C) vertical installation)","Resistance to electrostatic discharge":"4 kV on contact IEC 61000-4-2 8 kV in air IEC 61000-4-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$38.10","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/8e6f9e37aa9bcae0581123da38d09d7e.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/TM5SDI2DF/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/TM5SDI2DF","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/TM5SDI2DF when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}