{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"TM5SDI4D","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"TM5SDI4D","canonicalUrl":"https://aoctrl.com/schneider/TM5SDI4D","factsUrl":"https://aoctrl.com/api/mcp/products/TM5SDI4D","rawCanonicalId":null},"summary":{"shortDescription":"DISCRETE INPUT MODULE, MODICON T","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"3.0 in (75 mm)","Width":"0.5 in (12.5 mm)","Height":"3.9 in (99 mm)","Marking":"CE","Category":"US1PC1222532","Standards":"IEC 61131-2 CSA C22.2 No 142 UL 508 CSA C22.2 No 213","Input filtering":"<= 100 ms hardware","Input impedance":"6.4 kOhm","lifecycle_stage":"current","Local signalling":"1 LED (green) for power supply 1 LED (red) for power supply 4 LEDs (green) for input status","Pollution degree":"2","Range of Product":"Modicon TM5","Shock resistance":"15 gn 11 ms","Relative humidity":"5...95 % without condensation","Operating altitude":"0...6561.68 ft (0...2000 m)","Discrete input logic":"Sink","Maximum voltage drop":"<2 V at 500 mA sensor supply","Vibration resistance":"1 gn 8.4...150 Hz) on DIN rail 3.5 mm 5...8.4 Hz) on DIN rail","Discrete input number":"4","Electrical Connection":"3 wires","Nbr. of units in pkg.":"1","Discrete input current":"3.75 mA at 24 V DC","Discrete input voltage":"24 V DC 20.4...28.8 V)","Power dissipation in W":"0.73 W","IP Degree of Protection":"IP20","Product or Component Type":"Discrete input module","Voltage state 0 guaranteed":"<= 5 V","Voltage state 1 guaranteed":">= 15 V","Typical current consumption":"28 mA 5 V DC 25 mA 24 V DC","Electromagnetic compatibility":"Electrostatic discharge immunity test, 4 kV on contact IEC 61000-4-2 Electrostatic discharge immunity test, 8 kV in air IEC 61000-4-2 Susceptibility to electromagnetic fields, 1 V/m 2...2.7 GHz IEC 61000-4-3 Susceptibility to electromagnetic fields, 10 V/m 80...2000 MHz IEC 61000-4-3 Electrical fast transient/burst immunity test, 1 kV I/O IEC 61000-4-4 Electrical fast transient/burst immunity test, 1 kV shielded cable IEC 61000-4-4 Electrical fast transient/burst immunity test, 2 kV power lines IEC 61000-4-4 1.2/50 µs shock waves immunity test, 0.5 kV differential mode IEC 61000-4-5 1.2/50 µs shock waves immunity test, 1 kV common mode IEC 61000-4-5 Conducted RF disturbances IEC 61000-4-6 Conducted and radiated emissions CISPR 11","Ambient air temperature for storage":"-40...158 °F (-40...70 °C)","Complementary/Discrete input number":"4 at 24 V DC","Ambient air temperature for operation":"14...131 °F (-10...55 °C) without derating horizontal installation) 14...140 °F (-10...60 °C) with derating factor horizontal installation) 14...122 °F (-10...50 °C) vertical installation)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$48.37 – $103.59","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/1c4f3066eb19cf6230a8ed6269f1081c.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/TM5SDI4D/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/TM5SDI4D","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/TM5SDI4D when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}