{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"TM5SDO6TBFS","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"TM5SDO6TBFS","canonicalUrl":"https://aoctrl.com/schneider/TM5SDO6TBFS","factsUrl":"https://aoctrl.com/api/mcp/products/TM5SDO6TBFS","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Modicon TM5 safety DC discrete output module, TM5SDO6TBFS, 6 digital outputs, 24 V DC 0.2 A per channel, SIL 3, IP20, 25 x 75 x 99 mm.","salesMarkdown":"## Safety-rated discrete output for SIL 3 / PL e applications The TM5SDO6TBFS is a Modicon TM5 safety DC discrete output module with six source outputs, each rated 0.2 A at 24 V DC (20.4...28.8 V). It carries SIL 3 certification per IEC 61508 and IEC 62061, and PL = e per EN 13849-1 — the highest performance level for safety-related control systems. Safety reliability data shows MTTFd > 100 years, PFD < 1E-5, and PFH < 1E-9, meaning the module is suitable for applications requiring continuous fault coverage without frequent proof-testing. ## Output current and common limits Each of the six outputs switches up to 0.2 A resistive at up to 500 Hz. The maximum current per output common is 2 A, so all six channels can be active simultaneously without exceeding the common rating. Peak output current is 12 A — useful for driving capacitive loads or short-duration inrush on solenoid valves, but the continuous per-channel limit governs steady-state wiring. Leakage current when switched off is 10 µA at 24 V DC, which prevents false activation of downstream loads in high-impedance circuits. ## Standards and environmental fit The module is CE marked and complies with UL 508, IEC 61131-2, CSA C22.2 No 142, EN 13849-1, IEC 61508, and IEC 62061. It is rated IP20, so it must be installed inside an enclosure with a minimum pollution degree 2 environment. Operating temperature range is 14...122 °F (-10...50 °C) for vertical mounting, or 14...131 °F (-10...55 °C) for horizontal installation. Storage range is -40...158 °F (-40...70 °C). Vibration resistance is 1 gn at 8.4...150 Hz on DIN rail, with 3.5 mm displacement at 5...8.4 Hz. Shock resistance is 15 gn for 11 ms — typical for industrial panel environments. ## Diagnostics and wiring Local signalling includes one green LED for power supply, one red LED for power supply, two red LEDs for safety status, and four red/orange LEDs for output status. This allows quick fault isolation without a programming terminal. Electrical connection uses 2-wire per channel, source logic. The module width is 25 mm (1.0 in), depth 75 mm (3.0 in), height 99 mm (3.9 in) — fits standard Modicon TM5 backplane slots. ## Sourcing and lifecycle No official successor or cross-reference is recorded — the module is the current safety output offering in the Modicon TM5 family. Availability and current pricing are confirmed at RFQ.","metaTitle":"Schneider TM5SDO6TBFS Safety DC Output Module, SIL 3","metaDescription":"Active Schneider Modicon TM5 safety DC discrete output module, 6 outputs at 24 V DC / 0.2 A per channel, SIL 3 / PL e. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Digital Output Modules"],"specifications":{"Depth":"3.0 in (75 mm)","Width":"1.0 in (25 mm)","title":"TM5SDO6TBFS","Height":"3.9 in (99 mm)","Marking":"CE","Category":"US1PC5218360","Standards":"UL 508 IEC 61131-2 CSA C22.2 No 142 EN 13849-1 IEC 61508 IEC 62061","description":"Safety dc discrete output module, Modicon TM5, digital 6O, 24V 0,2 A","Safety level":"SIL 3 IEC 61508 SIL 3 IEC 62061 PL = e EN 13849-1","lifecycle_stage":"current","Local signalling":"1 LED (green) for power supply 1 LED (red) for power supply 2 LEDs (red) for safety status 4 LEDs (red/orange) for output status","Pollution degree":"2","Range of Product":"Modicon TM5","Shock resistance":"15 gn 11 ms","Relative humidity":"5...95 % without condensation","Operating altitude":"0...6561.68 ft (0...2000 m)","Current per channel":"0.2 A","Peak output current":"12 A","Switching frequency":"<= 500 Hz resistive","Vibration resistance":"1 gn 8.4...150 Hz) on DIN rail 3.5 mm 5...8.4 Hz) on DIN rail","Discrete output logic":"Source","Electrical Connection":"2 wires","Nbr. of units in pkg.":"1","Discrete output number":"6","Discrete output voltage":"24 V DC 20.4...28.8 V)","IP Degree of Protection":"IP20","Maximum leakage current":"10 µA 24 V DC when switched off","Safety reliability data":"MTTFd > 100 years PFD < 1E-5 PFH < 1E-9","Product or Component Type":"Safety dc discrete output module","Electromagnetic compatibility":"Electrostatic discharge immunity test, 4 kV on contact IEC 61000-4-2 Electrostatic discharge immunity test, 8 kV in air IEC 61000-4-2 Susceptibility to electromagnetic fields, 10 V/m 80...2000 MHz IEC 61000-4-3 Electrical fast transient/burst immunity test, 1 kV I/O IEC 61000-4-4 Electrical fast transient/burst immunity test, 1 kV shielded cable IEC 61000-4-4 Electrical fast transient/burst immunity test, 2 kV power lines IEC 61000-4-4 1.2/50 µs shock waves immunity test, 0.5 kV differential mode IEC 61000-4-5 1.2/50 µs shock waves immunity test, 1 kV common mode IEC 61000-4-5 Conducted RF disturbances IEC 61000-4-6 Conducted and radiated emissions CISPR 11","Maximum current per output common":"2 A","Ambient air temperature for storage":"-40...158 °F (-40...70 °C)","Complementary/Discrete output number":"6 at 24 V DC","Ambient air temperature for operation":"14...122 °F (-10...50 °C) vertical installation) 14...131 °F (-10...55 °C) horizontal installation)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$281.94 – $612.00","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/1d7257103a9fbea1bd2fc319cb37d34e.pdf","sourceUrl":"https://www.se.com/be/en/product/TM5SDO6TBFS/safety-dc-discrete-output-module-modicon-tm5-digital-6o-24v-02-a/"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/TM5SDO6TBFS","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/TM5SDO6TBFS when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}