{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"TM5SE1SC10005","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"TM5SE1SC10005","canonicalUrl":"https://aoctrl.com/schneider/TM5SE1SC10005","factsUrl":"https://aoctrl.com/api/mcp/products/TM5SE1SC10005","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Modicon TM5 counter module SE1SC10005, 1 absolute encoder input, 1 MHz counting frequency, 32-bit resolution, 24 V DC supply, 12.5 mm wide.","salesMarkdown":"## Module function and fit The TM5SE1SC10005 is a Modicon TM5 counter module with one 24 V DC sink input for an absolute encoder (5 V compatible). Counting frequency is 1 MHz with 32-bit resolution, and the maximum cycle time is 2 ms — fast enough for single-axis position tracking in a compact machine. Physical footprint is a standard TM5 slice: 12.5 mm wide (0.5 in), 75 mm deep (3.0 in), 99 mm tall (3.9 in). Mounts on DIN rail with IP20 protection. The module draws 2 mA from the 5 V bus and up to 63 mA from the 24 V I/O supply. ## Position vs TM5SE1IC20005 The TM5SE1SC10005 is designed for absolute encoders; the TM5SE1IC20005 handles incremental encoders. Both are 12.5 mm wide TM5 slices with the same backplane power budget, but the input stage and wiring differ. Dropping the SC10005 into a panel wired for an incremental encoder would require rewiring the encoder cable and reconfiguring the logic in the controller — not a mechanical swap. No end-of-life notice or last-time-buy schedule at this time. ## Environmental limits Operating temperature: 0 to 55 °C horizontally without derating, up to 60 °C with derating, and 0 to 50 °C vertically. Storage from -25 to 70 °C. Vibration resistance 1 gn (8.4–150 Hz) on DIN rail; shock 15 gn for 11 ms. Pollution degree 2 per IEC 60664.","metaTitle":"Schneider TM5SE1SC10005 Counter Module, 1 Absolute Encoder,","metaDescription":"Schneider Modicon TM5SE1SC10005 counter module for 1 absolute encoder. 1 MHz count frequency, 32-bit, 24 VDC. CE/UL/CSA. Current production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"3.0 in (75 mm)","Width":"0.5 in (12.5 mm)","Height":"3.9 in (99 mm)","Marking":"CE","Category":"US1PC1222532","Isolation":"500 Vrms AC insulation between channel and bus","Standards":"CSA C22.2 No 213 IEC 61131-2 UL 508 CSA C22.2 No 142","Encoder type":"1 absolute encoder","Surge withstand":"0.5 kV differential mode IEC 61000-4-5 1 kV common mode IEC 61000-4-5","lifecycle_stage":"current","Input resistance":"7.19 kOhm","Pollution degree":"2 IEC 60664","Range of Product":"Modicon TM5","Shock resistance":"15 gn 11 ms","Storage altitude":"0...9842.5 ft (0...3000 m)","DC supply voltage":"24 V","Relative humidity":"5...95 % without condensation","Counting frequency":"1 MHz","Function of module":"2 x 24 V DC sink auxiliary inputs 24 V DC encoder power supply","Maximum cycle time":"2 ms","Operating altitude":"0...6561.68 ft (0...2000 m)","Current consumption":"2 mA 5 V DC bus 63 mA 24 V DC input/output","Input compatibility":"1 absolute encoder (5 V)","Discrete input logic":"Sink","Vibration resistance":"1 gn 8.4...150 Hz DIN rail 3.5 mm 5...8.4 Hz DIN rail","Discrete input number":"1","Nbr. of units in pkg.":"1","Discrete input current":"3.3 mA 24 V","Discrete input voltage":"24 V DC","IP Degree of Protection":"IP20","IP degree of protection":"IP20IEC 61131-2","Counter inputs resolution":"32 bits","Product or Component Type":"Counter module","Electromagnetic compatibility":"EN/IEC 61000-4-6","Resistance to fast transients":"1 kV IEC 61000-4-4 I/O) 1 kV IEC 61000-4-4 shielded cable) 2 kV IEC 61000-4-4 power lines)","Disturbance radiated/conducted":"CISPR 11","Maximum power dissipation in W":"1.51 W","Ambient Air Temperature for Storage":"-13...158 °F (-25...70 °C)","Resistance to electromagnetic fields":"0.9 V/m (1 V/m) 2...2.7 GHz IEC 61000-4-3 9.1 V/m (10 V/m) 80...2000 MHz IEC 61000-4-3","Ambient air temperature for operation":"32...131 °F (0...55 °C) without derating horizontal installation) 32...140 °F (0...60 °C) with derating factor horizontal installation) 32...122 °F (0...50 °C) vertical installation)","Resistance to electrostatic discharge":"4 kV on contact IEC 61000-4-2 8 kV in air IEC 61000-4-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$205.74 – $582.00","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/9588966c16729d4cfa2961723f584dad.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/TM5SE1SC10005/alternatives.json"},"ai":{"faq":[{"question":"Will the TM5SE1SC10005 drop into a panel wired for the TM5SE1IC20005?","answer":"Mechanically both modules share the same TM5 12.5 mm form factor, but the TM5SE1SC10005 is for absolute encoders, while the TM5SE1IC20005 handles incremental encoders. Rewiring the encoder cable and reprogramming the counter logic is required."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/TM5SE1SC10005","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/TM5SE1SC10005 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}