{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"VFD007CB23A-20","brand":"Delta","brandSlug":"delta","productSlug":"VFD007CB23A-20","canonicalUrl":"https://aoctrl.com/delta/VFD007CB23A-20","factsUrl":"https://aoctrl.com/api/mcp/products/VFD007CB23A-20","rawCanonicalId":null},"summary":{"shortDescription":"Delta C200 Series VFD007CB23A-20, 230 V 3-phase economy vector control drive, 1 HP / 0.75 kW, 0.00–600.00 Hz output, wall mount, IP20.","salesMarkdown":"## Three-phase 230 V input drives a fractional-horsepower motor class The Delta VFD007CB23A-20 is a 0.75 kW economy vector drive sized for the small three-phase motor work that fills packaging skids, small fans, and short conveyors — wall-mounted beside the motor rather than in a washdown field enclosure (IP20 / UL Open Type). Running on 230 V three-phase input and pulling 6.4 A, it drives a 1 HP / 0.75 kW induction or PM motor with V/F, sensorless vector (SVC), or closed-loop vector (FOC+PG) control methods selectable from the keypad. ## Output envelope and torque headroom Maximum output frequency is 0.00–600.00 Hz in normal duty and 0.00–300.00 Hz in heavy duty — the upper band is for high-speed spindle or blower use rather than simple variable-torque pumps and fans. Torque limit is capped at 200% of rated current, which is the conventional sensorless-vector ceiling for starting a load with high breakaway friction without a sizing buffer; applications with sustained overload demand should size the drive into the heavy-duty curve rather than the normal-duty curve. ## Lifecycle and supply for the C200 product line No stock-holding promise here — the lead-time band on the listing typically lands in the single-digit working-days range once a quote is accepted. ## Same-frame C200 variants worth knowing Within the same C200 mechanical frame and 1 HP / 0.75 kW motor rating, the 230 V single-phase input VFD007CB21A-20 draws 12 A on /L2 only — useful where only utility single-phase is available, while the 480 V three-phase VFD007CB43A-20 sits at 4.3 A for plant floors fed from a 460 V bus. Both keep the same wall-mount footprint, keypad, and parameter structure as VFD007CB23A-20. None of these three are drop-in replacements on a wiring-terminal basis: the supply terminal count and the input current draw shift with the input class, so a panel specified around one variant needs its terminal block re-confirmed before the drive is swapped in.","metaTitle":"Delta VFD007CB23A-20, 0.75 kW, 230 V 3-Phase AC Drive, C200","metaDescription":"Delta C200 VFD007CB23A-20 economy vector drive, 1 HP / 0.75 kW, 230 V 3-phase input, wall mount, IP20. Quoted to order against the BOM.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["AC Drive (VFD) 240V"],"specifications":{"title":"VFD007CB23A-20","Weight":"1.5 Kg","Version":"A=Wall mount","C200 Series":"CB","Product No.":"VFD007CB23A-20","Series Name":"VFD = Variable Frequency Drive","description":"Economy Vector Control Drive C200 Series","Product type":"Economy Vector Control Drive C200 Series","IP Protection":"20: IP20/UL Open Type","Input Current":"6.4","Input Voltage":"23: 230 V 3-PHASE","Control Method":"1: V/F, 2: SVC, 3: VF+PG, 4: FOC+PG","Shipping Weight":"3 Kg","lifecycle_stage":"current","Torque Limit Max.":"200% torque current","Estimated Lead Time":"Usually ships in 1-10 working days.","Applicable motor capacity":"007:1 HP(0.75 kW)","Max. Output Frequency (Hz)":"normal duty: 0.00~600.00Hz; Heavy duty: 0.00 ~ 300.00 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$326.00","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/88a2a627c2d123c1357a0a0041df5ea1.pdf","sourceUrl":null},"ai":{"faq":[{"question":"Will VFD007CB23A-20 drop into a panel specified around VFD007CB21A-20 without rewiring?","answer":"No — both sit in the same C200 1 HP / 0.75 kW mechanical frame, but the 230 V single-phase VFD007CB21A-20 draws 12 A on a two-terminal input, while the 230 V three-phase VFD007CB23A-20 uses all three line terminals at 6.4 A. The input-terminal landing and upstream breaker sizing both need re-confirmation before the swap is made."},{"question":"What motor size runs on VFD007CB23A-20?","answer":"The drive is rated for a 1 HP / 0.75 kW motor on 230 V three-phase input, with up to 0.00–600.00 Hz output in normal duty or 0.00–300.00 Hz in heavy duty."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/delta/VFD007CB23A-20","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/delta/VFD007CB23A-20 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}