{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"VFD0185B43A","brand":"Delta","brandSlug":"delta","productSlug":"VFD0185B43A","canonicalUrl":"https://aoctrl.com/delta/VFD0185B43A","factsUrl":"https://aoctrl.com/api/mcp/products/VFD0185B43A","rawCanonicalId":null},"summary":{"shortDescription":"Delta VFD-B Series, Variable Frequency Drive, VFD0185B43A, 460V Three-Phase, 25 HP (18.5 kW), Fan Cooled, 13 kg.","salesMarkdown":"The Delta VFD0185B43A is a B-series variable-frequency drive rated for 25 HP (18.5 kW) on a 460V three-phase input. That 150% overload endurance for 1 minute means it can handle short-duration torque peaks—like starting a loaded conveyor or crusher—without tripping. The 0.01 Hz frequency-setting resolution gives fine speed control for applications where tight regulation matters, like a pump or fan following a pressure setpoint. ## Sizing and overload headroom The 150% overload for 1 minute is the figure that decides whether this drive holds a motor through a hard start. For a 25 HP motor driving a high-inertia load—say a centrifuge or a large fan—that minute of headroom buys you time to ramp up without nuisance tripping. The stall prevention level is adjustable from 20 to 250% of rated current, so you can dial it in to match the motor's thermal curve. ## Environmental limits and mounting This drive is fan-cooled, so panel placement needs clearance for airflow. Ambient humidity below 90% RH (non-condensing) keeps the electronics dry. Storage temperature from -20°C to 60°C covers most warehouse conditions, but the operating range is narrower—plan for a ventilated enclosure if the panel sees summer heat.","metaTitle":"Delta VFD0185B43A AC Drive, 25 HP, 460V Three-Phase, B Serie","metaDescription":"Delta VFD0185B43A AC drive rated 25 HP (18.5 kW) at 460V three-phase input, B series. 150% overload for 1 minute. Current lifecycle stage. Sourced to order against an RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":[],"specifications":{"Weight":"13 Kg","Product Type":"AC Drive Motors","Cooling Method":"Fan Cooled","Product Status":"Active","Temp Storage Max":"60 °C","Temp Storage Min":"-20 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$1,589.00","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/291df42255924d9877f5c5fc750a3a51.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/VFD0185B43A/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/delta/VFD0185B43A","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/delta/VFD0185B43A when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}