{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"VFD022M23A","brand":"Delta","brandSlug":"delta","productSlug":"VFD022M23A","canonicalUrl":"https://aoctrl.com/delta/VFD022M23A","factsUrl":"https://aoctrl.com/api/mcp/products/VFD022M23A","rawCanonicalId":null},"summary":{"shortDescription":"Delta VFD-M series VFD022M23A sensorless vector micro drive, 3-phase 200-240 VAC input, 2.2 kW / 3 HP motor output, 10 A rated output current, fan cooled.","salesMarkdown":"## Drive class and what it does Variable-frequency drive (VFD): a solid-state power converter that rectifies an AC mains supply into a DC link and re-inverts it to a variable-voltage, variable-frequency output, letting a standard induction motor run across a controlled speed range rather than at fixed line frequency. Delta's VFD-M series — to which the VFD022M23A belongs — is the general-purpose sensorless vector control micro-drive line, typically specified for fans, pumps, conveyors and small machine tools where compact panel footprint and basic closed-loop torque performance are wanted without stepping up to a higher-tier drive. ## Input ratings and mains tolerance Input is rated 200-240 VAC single- or three-phase at 50/60 Hz, with ±10% voltage tolerance (180-264 VAC) and ±5% frequency tolerance (47-63 Hz), so the drive rides through the usual generator and lightly loaded transformer excursions without tripping on its own supply monitor. The '23' in VFD022M23A marks the three-phase 230 V input variant; rated input current is 27 A on single-phase feed or 12.5 A on three-phase, with the three-phase figure of 12.5 A also applying when a single-phase model is wired across three-phase power. ## Output ratings and motor sizing Output is 3-phase, proportional to input voltage, at 10 A continuous rated current and 3.87 kVA rated output capacity, sized to a maximum applicable motor of 2.2 kW (3 HP) — so the drive's thermal ceiling is the current rating, not the kW label, and any motor pulled above 10 A on its nameplate will sit outside the drive's continuous envelope. Output frequency covers 0.1-400 Hz and the carrier is adjustable 1-15 kHz, so low-speed holding torque is available down to fractional Hz for slow conveyor indexing, while pushing carrier above the default 8 kHz region will trade acoustic noise for additional switching loss and require derating at the higher kHz settings.","metaTitle":"Delta VFD022M23A VFD, 2.2 kW, 3-phase 230V, 10 A","metaDescription":"Delta VFD022M23A VFD-M series micro drive, 3-phase 230V input, 2.2 kW / 3 HP at 10 A output.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["AC Drive (VFD) 240V"],"specifications":{"title":"VFD022M23A","Weight":"3.2 kg","Product no":"VFD022M23A","description":"General Sensorless Vector Control Micro Drives","Input Rating":"Rated Input Current : Single/3-phase , 27/12.5 Input Current for 1-phase Models when Using 3-phase Power : 12.5 Rated Voltage, Frequency : Single/3-phase 200-240 VAC, 50/60Hz Voltage Tolerance : ±10% (180~264 VAC) Frequency Tolerance : ± 5% (47~63 Hz)","Product type":"General Sensorless Vector Control Micro Drives VFD-M Series","Version Type":"A","Input Voltage":"23 - Three phase 230V","Output Rating":"Rated Output Capacity (kVA) : 3.87 Rated Output Current (A) : 10 Maximum Output Voltage (V) : 3-phase Proportional to Input Voltage Output Frequency (Hz) : 0.1~400 Hz Carrier Frequency (kHz) : 1-15","Voltage Class":"230V Class","Cooling Method":"Fan Cooled","Shipping Weight":"5 Kg","lifecycle_stage":"current","Voltage Tolerance":"±10% (180~264 VAC)","Estimated Lead Time":"Usually ships in 1-10 working days.","Frequency Tolerance":"± 5% (47~63 Hz)","Rated Input Current":"Single/3-phase , 27/12.5","Output Frequency (Hz)":"0.1~400 Hz","Carrier Frequency (kHz)":"1-15","Rated Output Current (A)":"10","Rated Voltage, Frequency":"Single/3-phase 200-240 VAC, 50/60Hz","Applicable motor capacity":"022 - 3 HP(2.2kW)","Maximum Output Voltage (V)":"3-phase Proportional to Input Voltage","Rated Output Capacity (kVA)":"3.87","Max. Applicable Motor Output (hp)":"3.0","Max. Applicable Motor Output (kW)":"2.2","Input Current for 1-phase Models when Using 3-phase Power":"12.5"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$381.00","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/8907f7e547d09cbac1904d962d695ea6.pdf","sourceUrl":null},"ai":{"faq":[{"question":"What motor size does VFD022M23A drive?","answer":"Maximum applicable motor is 2.2 kW (3 HP) at 10 A continuous output current; the kW label and the ampere rating are both ceiling values, with the thermal limit set by the 10 A output figure."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/delta/VFD022M23A","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/delta/VFD022M23A when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}