{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"VFD110CP43B-21","brand":"Delta","brandSlug":"delta","productSlug":"VFD110CP43B-21","canonicalUrl":"https://aoctrl.com/delta/VFD110CP43B-21","factsUrl":"https://aoctrl.com/api/mcp/products/VFD110CP43B-21","rawCanonicalId":null},"summary":{"shortDescription":"Delta CP2000 series VFD110CP43B-21 fan/pump vector control drive, 460V 3-phase, 15 HP / 11.25 kW / 24 A, wall mount, IP20 / NEMA 1.","salesMarkdown":"## What the VFD110CP43B-21 covers on the BOM line The Delta VFD110CP43B-21 sits in the CP2000 fan/pump vector control line, specified for a 460V 3-phase input and rated to drive a 15 HP / 11.25 kW motor at 24 A — the kind of mid-frame load you see on AHUs, chilled-water pumps, and large cooling-tower fans. ## Sourcing posture for an installed CP2000 spare For a maintenance buyer holding a critical spare against an aging CP2000 panel, the practical question is lead-time, not EOL — keep one in the cabinet so a fan or pump swap doesn't idle the line while the drive is on the dock. ## Upsizing from the 110 frame to the 150 frame If a panel was originally specified around the 20 HP / 32 A VFD150CP43B-21, the 110-frame drive at 24 A is the smaller motor — same CP2000 family, same 460V 3-phase input class, but it cannot carry a 32 A motor load without tripping or current-limiting on the rating itself. The reverse — dropping the VFD110CP43B-21 into a slot built for the 150-frame — keeps the wall-mount footprint consistent within the CP2000 family but undersizes the drive for the larger motor; verify motor FLA against the 24 A rating before commissioning.","metaTitle":"Delta VFD110CP43B-21 CP2000 VFD, 15 HP, 460V 3-Phase","metaDescription":"Delta VFD110CP43B-21 CP2000 fan/pump vector drive, 15 HP / 11.25 kW at 460V 3-phase. Wall-mount, IP20. Quoted to order against the BOM.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["AC Drive (VFD) 480V"],"specifications":{"title":"VFD110CP43B-21","Weight":"7 Kg","Dimensions":"7.48in(W) X 12.60in (H) X 7.48in (D)","Product No.":"VFD110CP43B-21","description":"Fan/Pump Vector Control Drive","Product Type":"Fan/Pump Vector Control Drive","VFD - Product":"Variable Frequency Drive","Shipping Weight":"8 Kg","lifecycle_stage":"current","CP - Product Series":"CP2000","Estimated Lead Time":"1 - 10 Working days.","B - Installation Type":"Wall Mount","2 - IP Protection Level":"IP20","1 - NEMA Protection Level":"NEMA 1","43 - Input Voltage/ Phase":"460V 3-Phase","110 - Applicable Motor Capacity":"15 HP - 11.25 kW - 24 Amps"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$467.00","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/bb69997d67c14a3e81cd93b47de8918e.pdf","sourceUrl":null},"ai":{"faq":[{"question":"What motor will the VFD110CP43B-21 actually carry?","answer":"The drive is rated for a 15 HP / 11.25 kW motor at 24 A on a 460V 3-phase supply — typical fan and pump duty, not constant-torque conveyor or crusher work. Size the motor nameplate FLA against the 24 A figure, not against HP alone, because FLA varies with motor efficiency class."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/delta/VFD110CP43B-21","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/delta/VFD110CP43B-21 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}