{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"VFD11AMH21ANSAA","brand":"Delta","brandSlug":"delta","productSlug":"VFD11AMH21ANSAA","canonicalUrl":"https://aoctrl.com/delta/VFD11AMH21ANSAA","factsUrl":"https://aoctrl.com/api/mcp/products/VFD11AMH21ANSAA","rawCanonicalId":null},"summary":{"shortDescription":"Delta VFD11AMH21ANSAA, frequency converter variable speed AC motor drive, 1-phase 200–240 V, 2.2 kW / 3 HP, 12.5 A output, Frame C, natural cooling, IP20.","salesMarkdown":"## 2.2 kW at 240 V single-phase in a Frame C footprint The Delta VFD11AMH21ANSAA is a 1-phase 200–240 V variable-speed drive in the M-Series compact frame, rated to drive a 2.2 kW / 3 HP motor at 12.5 A continuous output (cite:,). That rating fixes the application slot: small conveyors, fans, pumps and small mixers where single-phase mains is all the panel has, and the motor frame is IEC 90 or NEMA 143/145. Frame C keeps the panel footprint tight enough to sit next to a breaker column in a 300 mm-deep enclosure, and the natural-cooling design means no fan filter to clean on the washdown-adjacent lines where IP20 is the panel-side barrier, not the cabinet-side (cite:,). ## Duty ratings — heavy vs normal actually decides the fit Two published current numbers sit on the same nameplate: 24.2 A heavy-duty input and 27.5 A normal-duty input, which gate the upstream breaker or fuse selection (cite:,). Picking normal duty is how Delta stretches the drive to a slightly larger motor for variable-torque loads like fans and centrifugal pumps; heavy duty is the conservative call for constant-torque conveyors, hoists and extruders where stall torque matters. Carrier frequency defaults to 4 kHz and can be raised to 15 kHz — the higher kHz quiets motor whine but pushes additional switching loss into the IGBTs, so a derating on continuous output is the expected trade-off the installer should plan for (cite:). ## Sourcing posture and lifecycle read The listed lifecycle stage is current production, with an estimated lead time of 1–10 working days from the catalog line (cite:,). No official successor or cross-reference appears in the record, so the BOM position stays on this exact order code rather than a re-specified variant — that keeps the spare in the storeroom swappable with anything already wired against the M-Series template.","metaTitle":"Delta VFD11AMH21ANSAA, 240V 2.2 kW, Frame C","metaDescription":"Delta VFD11AMH21ANSAA compact drive, 1-phase 200–240 V, 2.2 kW / 3 HP, 12.5 A output, Frame C, quoted to order against an RFQ with availability confirmed at","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["AC Drive (VFD) 240V"],"specifications":{"Frame":"C","title":"VFD11AMH21ANSAA","EMC Filter":"Optional","Heavy Duty":"24.2","Normal Duty":"27.5","Product No.":"VFD11AMH21ANSAA","description":"Frequency Converter Variable Speed AC Motor Drives","Product Type":"Frequency Converter Variable Speed AC Motor Drives","Cooling Method":"Natural cooling","Shipping Weight":"3 Kg","lifecycle_stage":"current","Estimated Lead Time":"1 - 10 working days.","Frequency Tolerance":"47~63 Hz","Carrier Frequency (kHz)":"2~15 (Factory setting: 4)","Operating Voltage Range":"170~265 Vac","Rated Input Current (A)":"Heavy Duty : 24.2Normal Duty : 27.5","Rated Output Current (A)":"12.5","Ingress Protection Rating":"IP20","Rated Voltage / Frequency":"1-phase AC 200V~240V (-15% ~ +10%), 50/60 Hz","Rated Output Capacity (KVA)":"4.8","Applicable Motor Output (HP)":"3","Applicable Motor Output (kW)":"2.2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$361.00","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/94cab5abbf49f888c0c76aace8982c00.pdf","sourceUrl":null},"ai":{"faq":[{"question":"What current can VFD11AMH21ANSAA deliver, and what is the matching motor size?","answer":"Rated 12.5 A continuous output, sized for a 2.2 kW / 3 HP motor. Input draw is 24.2 A in heavy duty and 27.5 A in normal duty at the supply terminals, which is the figure the upstream breaker or fuse has to coordinate with."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/delta/VFD11AMH21ANSAA","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/delta/VFD11AMH21ANSAA when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}