{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"VW3A4562","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"VW3A4562","canonicalUrl":"https://aoctrl.com/schneider/VW3A4562","factsUrl":"https://aoctrl.com/api/mcp/products/VW3A4562","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar series line choke, VW3A4562, 0.049 mH, 429 A rated, 3-phase, 278 W thermal losses, IP00.","salesMarkdown":"The Schneider Altivar VW3A4562 is a three-phase line choke rated 429 A continuous with 0.049 mH inductance, designed to reduce current harmonics on variable-speed drive inputs. It handles 1.65× nominal current for 60 seconds — enough to ride through a motor start or a short overload without saturating the core. This part is obsolete per the manufacturer. No official successor is listed. Mounts as a line-side choke between the mains and the drive input. IP00 enclosure means it's intended for a cabinet — no washdown rating, no outdoor exposure. Bare-wire connection accepts up to 13 mm diameter cable. Thermal losses of 278 W need to be factored into the panel's cooling budget. Rated for 50/60 Hz supply. Voltage drop at rated load is 5%. Insulation is Class F. Pollution degree 2 per EN 50178, with 11.5 mm creepage and 5.5 mm clearance distances conforming to IEC 60664. Ambient operation is 0–45 °C without derating; above that, derate 2% per °C up to 55 °C. Altitude derating applies above 1000 m.","metaTitle":"Schneider Altivar VW3A4562 Line Choke, 429 A, 0.049 mH, Obso","metaDescription":"Schneider Altivar VW3A4562 line choke, 429 A rated, 0.049 mH, 3-phase, 278 W losses. Obsolete — sourced to order against RFQ. Standards IEC 60076, VDE 0160 level 1.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"IP Rating":"IP00","Application":"Reduction of current harmonics","Product Status":"Mature","Pollution Degree":"2 conforming to EN 50178","Temp Storage Max":"70 °C","Temp Storage Min":"-25 °C","Temp Operating Max":"55 °C","Temp Operating Min":"0 °C","Temperature Storage":"-25...70 °C","Main Product Or Component Type":"Line choke","Ambient Air Temperature Operation":"45...55 °C (with current derating of 2 % per °C) 0...45 °C (without current derating)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f5924190c6066d0db0fd4735b77a58b3.pdf","sourceUrl":"https://www.se.com/hk/en/product/VW3A4562/line-choke-0-049-mh-429-a-3-phases-278-w-for-variable-speed-drive/","alternativesUrl":"https://aoctrl.com/api/mcp/products/VW3A4562/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/VW3A4562","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/VW3A4562 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}