{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"VW3A46107A","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"VW3A46107A","canonicalUrl":"https://aoctrl.com/schneider/VW3A46107A","factsUrl":"https://aoctrl.com/api/mcp/products/VW3A46107A","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Easy Altivar 610 passive filter, VW3A46107A, 50 A output, 380-480 V, 22 kW/30 hp, 50 Hz, THDI 10%, IP20.","salesMarkdown":"## Passive filter for ATV610 drives — 22 kW, 50 A output, THDI 10% The VW3A46107A is a passive filter designed to pair with a Schneider ATV610 variable speed drive running a 22 kW / 30 hp motor on a 380-480 V three-phase line. It knocks input current harmonics down to 10 % THDI, which keeps the drive from rattling the rest of the panel's gear — especially important on shared transformers or generator-fed sites. The filter is rated for 32.5 A on the input side and 50 A on the output, so it handles the drive's full draw without choking. Efficiency sits at 98 %, with 327 W of thermal losses to vent. That's heat you need to account for in the enclosure — at full load it's about the same as a small space heater running inside the cabinet. Mounting is IP20, so it's meant for a clean, dry panel environment, not out in the washdown zone. The 10 % THDI figure is what matters most here. Without a line filter, a standard VFD can push higher THDI back onto the line, tripping nuisance breakers or overheating transformers upstream. This filter brings that down to 10 %, which is clean enough to meet most plant power-quality specs without going to a full active front end. The UL 61800-5-1 and IEC 61800-5-1 certifications mean it's tested as part of a drive system for both safety and harmonic limits — not just a standalone choke. The 50 A output rating matches the drive's nominal current for a 22 kW motor at 400 V. The input rating of 32.5 A reflects the lower current draw on the line side after the filter's inductive stage. Connection terminals accept up to 10 mm² on the power lines and 2.5 mm² for the DC bus links — solid for the wire sizes you'd run on a 22 kW drive.","metaTitle":"Schneider VW3A46107A Passive Filter, 50 A, 380-480 V, 22 kW,","metaDescription":"VW3A46107A passive filter for ATV610 drives: 50 A output, 380-480 V, 22 kW, THDI 10%, 98% efficiency, UL 61800-5-1. Active production. Available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"IP Rating":"IP20","Efficiency":"98%","Product Status":"Mature","Temp Storage Max":"85 °C","Temp Storage Min":"-25 °C","Temp Operating Max":"45 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-25...85 °C storage in original packaging","Main Product Or Component Type":"Passive filter","Ambient Air Temperature Operation":"-25...45 °C (without current derating)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d9407e52635c28a5ed7f6fb083346084.pdf","sourceUrl":"https://www.se.com/vn/en/product/VW3A46107A/passive-filter-easy-altivar-610-50a-380-to-480v-22kw-50hz-for-variable-speed-drive/","alternativesUrl":"https://aoctrl.com/api/mcp/products/VW3A46107A/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/VW3A46107A","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/VW3A46107A when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}