{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"VW3A46110","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"VW3A46110","canonicalUrl":"https://aoctrl.com/schneider/VW3A46110","factsUrl":"https://aoctrl.com/api/mcp/products/VW3A46110","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Altivar passive filter VW3A46110, 90 A output, 400 V, 50 Hz, for harmonic reduction on ATV61W/71W/650/630/950/930 45 kW drives.","salesMarkdown":"The Schneider Electric VW3A46110 is a passive filter sized for a single Altivar variable-speed drive in the 45 kW / 60 hp range — one filter per drive, not shared across a DC bus. It bolts between the line supply and the drive input, knocking down current harmonics to meet IEC 61000-3-4, IEC 61000-3-12, and G5/4 engineering recommendation levels. The rated input current is 86 A, output 90 A, on a 400 V ±10 % three-phase network at 50 Hz ±2 %. Efficiency sits at 98 %, so the 428 W thermal loss is what the enclosure has to shed. ## Harmonic performance across drive models The THDI number depends on which drive it pairs with. On the ATV61W and ATV650, ATV630, ATV950, and ATV930 it holds THDI to 10 %. On the ATV61H, ATV71H, and ATV71W it lands at 16 %. Either way the filter brings the installation into compliance with the harmonic standards listed above — no separate line reactor needed for that job. The power factor correction curve is non-linear: cos phi hits 1 at 150 % line current, 0.99 at 100 %, and 0.85 at 75 % load. That means at light load the filter is less effective at correcting displacement power factor, but the harmonic reduction is still active. The filter carries IP20 as standard and IP55 when mounted inside an enclosure. Operating ambient is 5 °C to 45 °C with no derating; above that, up to 60 °C, derate 3 % per °C. Altitude derating starts at 1000 m — 5 % per additional 1000 m. Storage in original packaging is -25 °C to 55 °C; transport up to 65 °C. Relative humidity 5 % to 85 %, non-condensing. Vibration resistance per IEC 60068-2-6: 2 mm peak-to-peak at 5–13.2 Hz, 0.7 gn at 13.2–150 Hz. Electrical connections use terminals sized for 10–70 mm² on the power side and 2.5 mm² on the control terminals.","metaTitle":"VW3A46110 Passive Filter, 90A, 400V, 50Hz, for Altivar Drive","metaDescription":"Schneider Electric VW3A46110 passive filter for Altivar drives. 90A rated, 400V, 50Hz, THDI 10-16%, efficiency 98%. Active production, sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"THDI":"10 % for variable speed drive ATV61W motor: 45 kW/60 hp 16 % for variable speed drive ATV61H motor: 45 kW/60 hp 16 % for variable speed drive ATV71H motor: 45 kW/60 hp 16 % for variable speed drive ATV71W motor: 45 kW/60 hp 10 % for variable speed drive ATV650 motor: 45 kW/60 hp 10 % for variable speed drive ATV630 motor: 45 kW/60 hp 10 % for variable speed drive ATV950 motor: 45 kW/60 hp 10 % for variable speed drive ATV930 motor: 45 kW/60 hp","title":"VW3A46110","Cos phi":"1 (150 % of line current) 0.85 (75 % of line current) 0.99 (100 % of line current)","Standards":"IEC 61000-3-4 IEC 61000-3-12 IEC 61000-2-4 G5/4 engineering recommendation IEC 61000-3-2 IEC 61000-2-2","Efficiency":"98 %","Max current":"1.5 x nominal current (duration = 60 s)","description":"passive filter, Altivar, 90A, 400V, 50Hz, for variable speed drive","Thermal losses":"428 W","lifecycle_stage":"mature","Relative humidity":"5...85 % without condensation","Operating altitude":"> 1000...4000 m with current derating 5 % per 1000 m","Quantity per drive":"1 filter per drive for variable speed drive ATV61W motor: 45 kW/60 hp 1 filter per drive for variable speed drive ATV61H motor: 45 kW/60 hp 1 filter per drive for variable speed drive ATV71H motor: 45 kW/60 hp 1 filter per drive for variable speed drive ATV71W motor: 45 kW/60 hp 1 filter per drive for variable speed drive ATV650 wall mount, motor: 45 kW/60 hp 1 filter per drive for variable speed drive ATV630 wall mount, motor: 45 kW/60 hp 1 filter per drive for variable speed drive ATV950 wall mount, motor: 45 kW/60 hp 1 filter per drive for variable speed drive ATV930 wall mount, motor: 45 kW/60 hp","[In] rated current":"86 A for input 90 A for output","Vibration resistance":"2 mm peak to peak (f= 5...13.2 Hz) conforming to IEC 60068-2-6 0.7 gn (f= 13.2...150 Hz) conforming to IEC 60068-2-6","Electrical connection":"A, B terminal, connection capacity: 2.5 mm² X1-1...X2-3 terminal, connection capacity: 10...70 mm²","Power Supply Frequency":"50 Hz +/- 2 %","IP degree of protection":"IP20 IP55 (enclosure mounting)","Network number of phases":"3 phases","Product or component type":"Passive filter","[Us] rated supply voltage":"400 V +/- 10 %","Electrical insulation class":"Class F","Product specific application":"Reduction of current harmonics","Ambient air temperature for storage":"-25...55 °C storage in original packaging -25...65 °C during transport","Ambient air temperature for operation":"45...60 °C (with current derating 3 % per °C) 5...45 °C (without current derating)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$7,618.98","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/5036c10d35744664679fbdfc69ea12c3.pdf","sourceUrl":"https://www.se.com/hk/en/product/VW3A46110/passive-filter-altivar-90a-400v-50hz-for-variable-speed-drive/"},"ai":{"faq":[{"question":"What is the THDI of VW3A46110?","answer":"THDI is 10 % when paired with ATV61W, ATV650, ATV630, ATV950, or ATV930 drives, and 16 % with ATV61H, ATV71H, or ATV71W drives — all at 45 kW / 60 hp."},{"question":"What compliance standards does VW3A46110 meet?","answer":"It complies with IEC 61000-3-4, IEC 61000-3-12, IEC 61000-2-4, G5/4 engineering recommendation, IEC 61000-3-2, and IEC 61000-2-2."},{"question":"Where can I buy VW3A46110?","answer":"The VW3A46110 is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/VW3A46110","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/VW3A46110 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}