{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"VW3A46111","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"VW3A46111","canonicalUrl":"https://aoctrl.com/schneider/VW3A46111","factsUrl":"https://aoctrl.com/api/mcp/products/VW3A46111","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric, Altivar passive filter, VW3A46111, 105 A rated current, 400 V, 50 Hz, for variable speed drives up to 55 kW/75 hp.","salesMarkdown":"The Schneider VW3A46111 is a passive filter designed to reduce current harmonics on Altivar variable speed drives up to 55 kW/75 hp. It sits between the line supply and the drive input, cleaning up the current waveform so the installation meets IEC 61000-3-4, IEC 61000-3-12, and G5/4 harmonic limits. One filter per drive — no sharing across multiple units. Rated 101 A input and 105 A output at 400 V ±10 %, 50 Hz three-phase. That 105 A output rating is the figure to size conductors and upstream protection by — the input side is slightly lower because the filter itself draws magnetising current. THDI is 10 % on ATV61W, ATV650, ATV630, ATV950, and ATV930; 16 % on ATV61H and ATV71H/W. Residual harmonic current after filtering. Power factor correction is load-dependent: 0.99 at full load, 0.85 at 75 % load, and unity (1.0) at 150 % overload for up to 60 seconds. The filter's 98 % efficiency means 488 W of heat to dump into the enclosure — plan the cabinet ventilation around that, especially if the drive and filter share the same IP20 panel. This filter is still the current production part for the Altivar range it supports.","metaTitle":"Schneider VW3A46111 Passive Filter, 105A, 400V, 50Hz, for Al","metaDescription":"Schneider VW3A46111 passive filter reduces current harmonics for Altivar drives up to 55 kW/75 hp. Rated 105 A input/output, 400 V, 50 Hz. 98% efficiency, 488 W losses. Active prod","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"THDI":"10 % for variable speed drive ATV61W motor: 55 kW/75 hp 16 % for variable speed drive ATV61H motor: 55 kW/75 hp 16 % for variable speed drive ATV71H motor: 55 kW/75 hp 16 % for variable speed drive ATV71W motor: 55 kW/75 hp 10 % for variable speed drive ATV650 motor: 55 kW/75 hp 10 % for variable speed drive ATV630 motor: 55 kW/75 hp 10 % for variable speed drive ATV950 motor: 55 kW/75 hp 10 % for variable speed drive ATV930 motor: 55 kW/75 hp","title":"VW3A46111","Cos phi":"1 (150 % of line current) 0.85 (75 % of line current) 0.99 (100 % of line current)","Standards":"IEC 61000-3-4 IEC 61000-3-2 IEC 61000-3-12 IEC 61000-2-2 G5/4 engineering recommendation IEC 61000-2-4","Efficiency":"98 %","Max current":"1.5 x nominal current (duration = 60 s)","description":"passive filter, Altivar, 105A, 400V, 50Hz, for variable speed drive","Thermal losses":"488 W","lifecycle_stage":"mature","Relative humidity":"5...85 % without condensation","Operating altitude":"> 1000...4000 m with current derating 5 % per 1000 m","Quantity per drive":"1 filter per drive for variable speed drive ATV61W motor: 55 kW/75 hp 1 filter per drive for variable speed drive ATV61H motor: 55 kW/75 hp 1 filter per drive for variable speed drive ATV71H motor: 55 kW/75 hp 1 filter per drive for variable speed drive ATV71W motor: 55 kW/75 hp 1 filter per drive for variable speed drive ATV650 wall mount, motor: 55 kW/75 hp 1 filter per drive for variable speed drive ATV630 wall mount, motor: 55 kW/75 hp 1 filter per drive for variable speed drive ATV950 wall mount, motor: 55 kW/75 hp 1 filter per drive for variable speed drive ATV930 wall mount, motor: 55 kW/75 hp","[In] rated current":"101 A for input 105 A for output","Vibration resistance":"2 mm peak to peak (f= 5...13.2 Hz) conforming to IEC 60068-2-6 0.7 gn (f= 13.2...150 Hz) conforming to IEC 60068-2-6","Electrical connection":"A, B terminal, connection capacity: 2.5 mm² X1-1...X2-3 terminal, connection capacity: 10...70 mm²","Power Supply Frequency":"50 Hz +/- 2 %","IP degree of protection":"IP20 IP55 (enclosure mounting)","Network number of phases":"3 phases","Product or component type":"Passive filter","[Us] rated supply voltage":"400 V +/- 10 %","Electrical insulation class":"Class F","Product specific application":"Reduction of current harmonics","Ambient air temperature for storage":"-25...55 °C storage in original packaging -25...65 °C during transport","Ambient air temperature for operation":"45...60 °C (with current derating 3 % per °C) 5...45 °C (without current derating)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$8,465.62","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/6a698f64ad8b3555a3cf6fbf95624e2b.pdf","sourceUrl":"https://www.se.com/vn/en/product/VW3A46111/passive-filter-altivar-105a-400v-50hz-for-variable-speed-drive/"},"ai":{"faq":[{"question":"What drives does the VW3A46111 filter work with?","answer":"It fits Altivar ATV61W, ATV61H, ATV71H, ATV71W, ATV650, ATV630, ATV950, and ATV930 drives rated 55 kW/75 hp. One filter per drive — not shared across multiple units."},{"question":"What THDI does the VW3A46111 achieve?","answer":"THDI is 10 % on ATV61W, ATV650, ATV630, ATV950, and ATV930 drives; 16 % on ATV61H and ATV71H/W drives. That's the residual harmonic current after filtering."},{"question":"What compliance standards does the VW3A46111 meet?","answer":"It complies with IEC 61000-3-4, IEC 61000-3-2, IEC 61000-3-12, IEC 61000-2-2, IEC 61000-2-4, and the UK G5/4 engineering recommendation for harmonic emissions."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/VW3A46111","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/VW3A46111 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}