{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"VW3A46151","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"VW3A46151","canonicalUrl":"https://aoctrl.com/schneider/VW3A46151","factsUrl":"https://aoctrl.com/api/mcp/products/VW3A46151","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric VW3A46151 passive harmonic filter, 160 A rated current, 480 V AC, 60 Hz, for Altivar variable speed drives 90 kW/125 hp.","salesMarkdown":"The VW3A46151 is a passive harmonic filter from Schneider Electric, designed to reduce current harmonics on the line side of Altivar variable speed drives. It's rated for 154 A input / 160 A output at 480 V +/- 10 %, 60 Hz, and delivers a total harmonic current distortion (THDI) of 10 % when paired with drives rated 90 kW / 125 hp — covering the ATV61H, ATV61W, ATV71H, ATV71Q, ATV650, ATV630, ATV950, and ATV930 series. ## Harmonic performance and standards compliance A THDI of 10 % means this filter brings the drive's line current distortion well within the limits of IEC 61000-3-4 and IEC 61000-3-12, which govern connection of equipment to public low-voltage supply networks. It also complies with IEC 61000-2-4 (industrial environment compatibility), IEC 61000-2-2 (public LV compatibility), and the UK G5/4 engineering recommendation. For a plant electrical engineer, this is the filter that keeps the site from failing harmonic surveys or triggering penalties from the utility. The filter's power factor (cos phi) varies with load: 1.0 at 150 % of line current, 0.99 at 100 %, and 0.85 at 75 %. That means at full load the filter presents near-unity power factor, drawing essentially reactive-free current from the supply — useful for avoiding PF correction capacitor interaction. Efficiency is listed at 98 %, with thermal losses of 692 W at rated load. That 692 W has to be dissipated inside the enclosure — factor it into your panel cooling budget, especially if the filter shares a cabinet with the drive. ## Installation and integration notes One filter per drive is required for the listed Altivar models at 90 kW / 125 hp. The filter is a three-phase passive device with IP20 protection as standard, and IP55 when mounted inside an enclosure. Terminal connections: control wiring at 2.5 mm² on the X1/X2 blocks, power wiring at 2.5...90 mm² on the A/B terminals. Operating temperature range is 5...45 °C without derating; above that, derate 3 % per °C up to 60 °C. Altitude derating applies above 1000 m — 5 % per additional 1000 m.","metaTitle":"VW3A46151 passive filter, 160 A, 480 V, 60 Hz, obsolete","metaDescription":"Schneider Electric VW3A46151 passive harmonic filter, 160 A input/output, 480 V, 60 Hz. THDI 10% for ATV6xx/7xx/9xx drives at 90 kW/125 hp. Obsolete — sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"IP Rating":"IP20 / IP55","Efficiency":"98%","Product Status":"Mature","Temp Storage Max":"65 °C","Temp Storage Min":"-25 °C","Temp Operating Max":"60 °C","Temp Operating Min":"5 °C","Main Product Or Component Type":"Passive filter"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/43f43126ef311201f15107121c87f165.pdf","sourceUrl":"https://www.se.com/ae/en/product/VW3A46151/passive-filter-160-a-460-v-60-hz-for-variable-speed-drive/","alternativesUrl":"https://aoctrl.com/api/mcp/products/VW3A46151/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/VW3A46151","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/VW3A46151 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}