{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"VW3A4706","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"VW3A4706","canonicalUrl":"https://aoctrl.com/schneider/VW3A4706","factsUrl":"https://aoctrl.com/api/mcp/products/VW3A4706","rawCanonicalId":null},"summary":{"shortDescription":"Square D VW3A4706 Drive Emc Filter|Square D VW3A4706 Drive Emc Filter","salesMarkdown":null,"metaTitle":"Schneider VW3A4706 Drive EMC Filter","metaDescription":"Schneider VW3A4706 EMC emissions filter for variable frequency drive installations.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"7.09 in (180 mm)","Phase":"Three phase","Width":"4.7 in (120 mm)","Height":"13.4 in (340 mm)","Category":"US1000I22000","Standards":"IEC 61800-3","Tolerance":"10 %","Thermal losses":"12.4 W","lifecycle_stage":"mature","Range of Product":"Altivar","Mounting Location":"At variable speed drive side","Relative humidity":"5...95 % without condensation IEC 61800-5-1","Line Rated Current":"100 A","Operating altitude":"0...3280.84 ft (0...1000 m) without current derating 3280.84...13123.36 ft (1000...4000 m) with current derating 1 % per 100 m","Power Supply Voltage":"380...480 V 200...240 V","Electrical connection":"Terminal 50 mm² AWG 1/0","Mechanical robustness":"Shocks class 3M4 IEC 60721-3-3 Vibrations class 3M4 IEC 60721-3-3","Nbr. of units in pkg.":"1","IP degree of protection":"IP20mounting side by side IP21with kit VW3A47906","Product or Component Type":"EMC input filter","Maximum motor cable length":"492.1 ft (150 m) shielded motor cable 4 kHz IEC 61800-3 category C2, 380...480 V 984.3 ft (300 m) shielded motor cable 4 kHz IEC 61800-3 category C3, 380...480 V 492.1 ft (150 m) shielded motor cable 4 kHz IEC 61800-3 category C2, 200...240 V 984.3 ft (300 m) shielded motor cable 4 kHz IEC 61800-3 category C3, 200...240 V 164.04 ft (50 m) shielded motor cable 4 kHz IEC 61800-3 category C1, 200...240 V 164.04 ft (50 m) shielded motor cable 4 kHz IEC 61800-3 category C1, 380...480 V","Product Specific Application":"Radio interference input filter","Maximum Earth Leakage Current":"13.9 mA 400 V 50 Hz TN 13.9 mA 400 V 50 Hz TT","Ambient Air Temperature for Storage":"-40...158 °F (-40...70 °C)","Ambient air temperature for operation":"14...122 °F (-10...50 °C) (without current derating) 122...140 °F (50...60 °C) (with current derating 1.5 % per °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$511.81 – $1,135.00","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/71edccbde7dc028a93d12cf6782df543.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/VW3A4706/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/VW3A4706","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/VW3A4706 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}