{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"VW3A58501","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"VW3A58501","canonicalUrl":"https://aoctrl.com/schneider/VW3A58501","factsUrl":"https://aoctrl.com/api/mcp/products/VW3A58501","rawCanonicalId":null},"summary":{"shortDescription":"line choke - 2 mH - 25 A - 1 phase - 45 W - for variable speed drive","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Depth":"3.7 in (95 mm)","Width":"5.2 in (133 mm)","Height":"5.9 in (150 mm)","Category":"22058-ATV58 OPTIONS AND ACCESSORIES","Standards":"VDE 0160 level 1 EN 50178 IEC 60076 (with HD398)","Max current":"1.65 x nominal current 60 s)","Thermal losses":"45 W","lifecycle_stage":"mature","Leakage distance":"0.5 in (11.5 mm) IEC 60664","Number Of Phases":"Single phase","Pollution degree":"2 EN 50178","Range of Product":"Altivar","Shock resistance":"15 gn 11 ms IEC 60068-2-27","Relative humidity":"0...95 %","Device Application":"Reduction of current harmonics","Line Rated Current":"25 A","Operating altitude":"3280.84...9842.52 ft (1000...3000 m) with current derating 1 % per 100 m","Value of inductance":"2 mH","Vibration resistance":"1 gn (f= 13...200 Hz) conforming to IEC 60068-2-6 1.5 mm peak to peak (f= 3...13 Hz) conforming to IEC 60068-2-6","Electrical connection":"Terminal 16 mm² / AWG 4, 10.6...12.4 lbf.in (1.2...1.4 N.m)","Nbr. of units in pkg.":"1","Power Supply Frequency":"50...60 Hz","IP Degree of Protection":"Choke IP00 Terminals IP20","Product or Component Type":"Line choke","Minimum clearance distance":"0.2 in (5.5 mm) IEC 60664","Electrical Insulation Class":"Class F","Environmental characteristic":"3B1 conforming to IEC 721-3-3 3C2 conforming to IEC 721-3-3 3S1 conforming to IEC 721-3-3","Maximum voltage drop at rated load":"5 %","Ambient Air Temperature for Storage":"-13...158 °F (-25...70 °C)","Ambient air temperature for operation":"113...131 °F (45...55 °C) (with current derating of 2 % per °C) 32...113 °F (0...45 °C) (without current derating)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/9dfb0cd5681d6bb980c11922e160c922.pdf","sourceUrl":"https://www.se.com/ae/en/product/VW3A58501/line-choke-2-mh-25-a-1-phase-45-w-for-variable-speed-drive/","alternativesUrl":"https://aoctrl.com/api/mcp/products/VW3A58501/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/VW3A58501","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/VW3A58501 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}