{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"VW3A7262","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"VW3A7262","canonicalUrl":"https://aoctrl.com/schneider/VW3A7262","factsUrl":"https://aoctrl.com/api/mcp/products/VW3A7262","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric VW3A7262, line filter module (LFM), 340 kW, 495 A at 50 °C, 380...480 V AC, IP00, built-in unit.","salesMarkdown":"The Schneider Electric VW3A7262 is a line filter module (LFM) designed as a component of the Active Front End (AFE) system. It mates specifically with one or two active infeed converters (AICs) in the VW3A7253 through VW3A7287 range, providing control electronics for the AIC and inverter plus a 24 V DC fan circuit that also powers up to four inverters of the same power rating on the 380...480 V AC bus. Rated line current is 495 A at 50 °C, with a power rating of 340 kW. The module handles 3-phase 380...480 V AC (±10 %) at 50/60 Hz network frequency. Thermal losses are 560 W, dissipated via natural convection — no forced-air fan on the filter itself, so panel airflow must be accounted for in the enclosure design. ## Physical integration and environmental limits The VW3A7262 is a built-in unit (IP00) — no enclosure, no touch-safe shrouding. Mounting dimensions: 1100 mm high × 290 mm wide × 379 mm deep. The 1100 mm height typically requires a tall cabinet; plan for bottom-entry cable management given the bar terminals at M10 accepting up to 2 × 185 mm² per phase on both line and load sides. Operating ambient temperature range is -10 to +45 °C, extendable to +60 °C with a 2 % per °C current derating. Altitude derating applies above 1000 m: 1 % per 100 m up to 3000 m. Pollution degree 2 per EN/IEC 61800-5-1, environmental class 3K3/3C2/3S2 per EN/IEC 60721-3-3. Shock resistance is 7 gn for 11 ms; vibration resistance is 1.5 mm at 3-10 Hz and 0.6 gn at 10-200 Hz per IEC 60068-2-6. The module carries conformity to EN/IEC 61800-5-1 for pollution degree 2, and environmental classification per EN/IEC 60721-3-3. The manufacturer's standard declaration of conformity covers the applicable EMC and low-voltage directives for the AFE system. For specific RoHS/REACH compliance documentation or a detailed certificate, request the manufacturer's declaration of conformity with your RFQ — this is typically provided at the time of quotation for obsolete parts sourced through independent channels.","metaTitle":"Schneider Electric VW3A7262 Line Filter Module, 495 A, 380-4","metaDescription":"VW3A7262 line filter module for Schneider Active Front End. 495 A at 50 °C, 380-480 V AC, 340 kW. Obsolete — sourced to order. Quoted on request.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Depth":"379 mm","Width":"290 mm","Height":"1100 mm","Output type":"Control electronics for AIC and inverter 24 V DC Fan for AIC and 4 inverters of the same power 380...480 V AC","Line current":"495 A at 50 °C","Assembly style":"Built-in unit","Thermal losses":"560 W","Type of cooling":"Natural convection","lifecycle_stage":"mature","Pollution degree":"2 conforming to EN/IEC 61800-5-1","Shock resistance":"7 gn for 11 ms conforming to EN/IEC 60068-2-27","Device short name":"LFM","Network frequency":"50/60 Hz","Relative humidity":"0...95 %","Operating altitude":"1000...3000 m with current derating 1 % per 100 m","Product destination":"1 active infeed converter (AIC) VW3A7253 1 active infeed converter (AIC) VW3A7254 1 active infeed converter (AIC) VW3A7255 2 active infeed converter (AIC) VW3A7256 2 active infeed converter (AIC) VW3A7257 2 active infeed converter (AIC) VW3A7258 1 active infeed converter (AIC) VW3A7283 2 active infeed converter (AIC) VW3A7286 2 active infeed converter (AIC) VW3A7287","Vibration resistance":"1.5 mm (f= 3...10 Hz) conforming to IEC 60068-2-6 0.6 gn (f= 10...200 Hz) conforming to IEC 60068-2-6","Electrical connection":"Bar M10 - 95 mm² 24 N.m (PE) Terminal - 2.5 mm² 0.6...0.8 N.m (X1:1...X1:6) Bar M10 - 2 x 185 mm² 24 N.m (1L1, 1L2, 1L3) Bar M10 - 2 x 185 mm² 24 N.m (2L1, 2L2, 2L3)","IP degree of protection":"IP00","Network number of phases":"3 phases","Product or component type":"Line filter module","[Us] rated supply voltage":"380...480 V +/- 10 %","Environmental characteristic":"3K3 conforming to EN/IEC 60721-3-3 3C2 conforming to EN/IEC 60721-3-3 3S2 conforming to EN/IEC 60721-3-3","Maximum number of switchings":"10 per hour","Product specific application":"Component of the Active Front End","Ambient air temperature for storage":"-25...70 °C","Ambient air temperature for operation":"-10...45 °C -10...60 °C (with current derating of 2 % per °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/22b30f584fe83685f0e9bc7e7aca23d8.pdf","sourceUrl":"https://www.se.com/vn/en/product/VW3A7262/line-filter-module-340-kw-380-480-v/","alternativesUrl":"https://aoctrl.com/api/mcp/products/VW3A7262/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy the VW3A7262 and how is it quoted?","answer":"The VW3A7262 is sourced through independent distribution channels. Submit an RFQ for current availability and pricing — confirmed at quote time."},{"question":"What is the closest alternative to the VW3A7262?","answer":"No direct pin-compatible or form-fit-function alternative is listed in the manufacturer's lifecycle record. For an existing AFE installation, the VW3A7262 is the specific line filter module designed for the listed AIC models; no drop-in substitute is documented."},{"question":"What are the physical dimensions of the VW3A7262?","answer":"Height 1100 mm, width 290 mm, depth 379 mm. It is a built-in unit (IP00) requiring a tall cabinet."},{"question":"What compliance documentation does Schneider provide for the VW3A7262?","answer":"The module is certified to EN/IEC 61800-5-1 (pollution degree 2) and classified per EN/IEC 60721-3-3 (3K3/3C2/3S2). The manufacturer's declaration of conformity covering EMC and low-voltage directives is available on request with an RFQ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/VW3A7262","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/VW3A7262 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}