{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"VW3S8201R05","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"VW3S8201R05","canonicalUrl":"https://aoctrl.com/schneider/VW3S8201R05","factsUrl":"https://aoctrl.com/api/mcp/products/VW3S8201R05","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric VW3S8201R05 connecting cable, shielded, 1.6 ft (0.5 m), 24-pin Molex SD326 connector one end, cable end open, for pulse/direction signal between SD326 stepper drive and external impulsion generator, 5 V control circuit.","salesMarkdown":"## What this cable connects and why it matters The VW3S8201R05 is the dedicated pulse/direction signal cable between a Schneider SD326 stepper drive and an external pulse generator — the part that carries the step and direction commands from the controller to the drive. Without it, the drive has no motion profile to execute. One end terminates in a 24-pin Molex SD326 connector that mates directly to the drive's control port; the other end is unterminated (cable end open) so you can wire it into the pulse generator's terminal block or connector of your choice. The cable is shielded — this matters in a stepper system because the pulse train is a fast-edged digital signal that radiates noise into adjacent wiring if unshielded. The shield drains that common-mode noise to ground at the drive end. ## Length, voltage, and what they mean for panel layout At 0.5 m (1.6 ft), this cable is meant for short panel-internal runs — the pulse generator sits in the same enclosure as the SD326 drive, not across the plant floor. Longer runs would need a differential line driver and a different cable assembly. The control circuit runs at 5 V, which is the logic level for most step/direction generators (PLC high-speed outputs, indexer modules, or dedicated pulse-train cards). Confirm your pulse source outputs a 5 V signal before committing — a 24 V pulse train will damage the drive input. It is a standard accessory for the SD326 series, so production is tied to the drive family's lifecycle.","metaTitle":"Schneider Electric VW3S8201R05 Pulse/Direction Cable, 0.5 m","metaDescription":"Schneider Electric VW3S8201R05 shielded cable, 0.5 m, with 24-pin Molex SD326 connector for pulse/direction signals between SD326 stepper drive and external","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Control Accessories"],"specifications":{"title":"VW3S8201R05","Category":"US1PC5518286","description":"Square D VW3S8201R05 P/D 5V Cable|Square D VW3S8201R05 P/D 5V Cable","Cable length":"1.6 ft (0.5 m)","Type of Cable":"Shielded cable","lifecycle_stage":"mature","Electrical connection":"1 connector 24-pole Molex SD326) Cable end open external impulsion generator)","Nbr. of units in pkg.":"1","[Uc] control circuit voltage":"5 V","Accessory / Separate Part Type":"Connecting cable","Accessory / separate part category":"Connection accessories","Accessory / separate part designation":"Cable for pulse/direction signal","Accessory / separate part destination":"Between stepper drive SD326 and external impulsion generator"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$396.00","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/043449a65dc0f70684957569fa4646ff.pdf","sourceUrl":"https://www.se.com/nz/en/product/VW3S8201R05/cable-for-pulse-direction-signal-lexium-sd3-5v-shielded-0-5m/"},"ai":{"faq":[{"question":"What is the cable length and connector type on VW3S8201R05?","answer":"The VW3S8201R05 is a shielded cable 0.5 m (1.6 ft) long. One end has a 24-pin Molex SD326 connector that plugs into the SD326 drive; the other end is unterminated for field wiring to the pulse generator."},{"question":"What voltage does the VW3S8201R05 cable carry?","answer":"The control circuit voltage is 5 V. This is the logic-level pulse/direction signal from the external generator to the SD326 drive. Do not connect 24 V signals to this cable — the drive input is 5 V only."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/VW3S8201R05","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/VW3S8201R05 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}