{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"XALD101H29","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"XALD101H29","canonicalUrl":"https://aoctrl.com/schneider/XALD101H29","factsUrl":"https://aoctrl.com/api/mcp/products/XALD101H29","rawCanonicalId":null},"summary":{"shortDescription":"Square D XALD101H29 Pushbutton|Square D XALD101H29 Pushbutton","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Category":"US10CS222475","Material":"Polycarbonate","Standards":"JIS C8201-5-1 IEC 60947-5-5 IEC 60947-1 CSA C22.2 No 14 UL 508 IEC 60947-5-4 IEC 60947-5-1 JIS C8201-1","Cable entry":"1 knock-out for cable entry 0.6 in (14 mm) 2 knock-outs for Pg 13 cable gland and ISO M20 0.5 in (12 mm)","Colour Of Cover":"Dark grey","Colour of cover":"Dark grey RAL 7016)","Operating force":"3.8 N NO changing electrical state","lifecycle_stage":"unknown","Marking location":"Marking on legend holder","Operating travel":"0.1 in (2.6 mm) NO changing electrical state) 0.2 in (4.3 mm) total travel)","Operator profile":"1 flush push-button","Positive opening":"Without","Range of Product":"Harmony XALD","Shock resistance":"30 gn 18 ms) half sine wave acceleration IEC 60068-2-27 50 gn 11 ms) half sine wave acceleration IEC 60068-2-27","Contact operation":"Slow-break","Contacts material":"Silver alloy (Ag/Ni)","Device short name":"XALD","Tightening torque":"7.08...10.6 lbf.in (0.8...1.2 N.m) IEC 60947-1","Product destination":"For XB5 Ø 22 mm control and signalling units","Shape of screw head":"Cross Philips no 1 Cross pozidriv No 1 Slotted flat Ø 4 mm Slotted flat Ø 5.5 mm","Overvoltage category":"Class II conforming to IEC 60536","Protective treatment":"TH","Vibration resistance":"5 gn (f= 12...500 Hz) conforming to IEC 60068-2-6","Electrical durability":"1000000 cycles, AC-15, 2 A 230 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C 1000000 cycles, AC-15, 3 A 120 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C 1000000 cycles, AC-15, 4 A 24 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C 1000000 cycles, DC-13, 0.2 A 110 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C 1000000 cycles, DC-13, 0.5 A 24 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C","Mechanical durability":"10000000 cycles","Nbr. of units in pkg.":"1","Operators description":"Green ''START'' 1 NO","Electrical reliability":"Λ < 10exp(-6) 5 V 1 mA IEC 60947-5-4 Λ < 10exp(-8) 17 V 5 mA IEC 60947-5-4","Number of key switches":"0","Number of push buttons":"1","Connections - terminals":"Screw clamp terminals, Screw clamp terminals, >= 1 x 0.22 mm² without cable end IEC 60947-1","IK degree of protection":"IK03 conforming to IEC 62262","IP Degree of Protection":"IP66/IP67/IP69/IP69K","IP degree of protection":"IP66 IEC 60529 IP67 IP69 IP69K","Short-circuit protection":"10 A cartridge fuse gG IEC 60947-5-1","NEMA Degree of Protection":"NEMA 4X/13","NEMA degree of protection":"NEMA 13 NEMA 4X","Product or Component Type":"Complete control station","Number of indicator lights":"0","Colour of base of enclosure":"Light grey RAL 7035)","Control station application":"Start function","Control station composition":"1 flush push-button, green 1 NO START","Number of command positions":"1","Number of selector switches":"0","[Ui] rated insulation voltage":"600 V 3)IEC 60947-1","[Ie] rated operational current":"6 A 120 V, AC-15, A600 IEC 60947-5-1 3 A 240 V, AC-15, A600 IEC 60947-5-1 1.2 A 600 V, AC-15, A600 IEC 60947-5-1 0.55 A 125 V, DC-13, Q600 IEC 60947-5-1 0.27 A 250 V, DC-13, Q600 IEC 60947-5-1 0.1 A 600 V, DC-13, Q600 IEC 60947-5-1","Resistance to high pressure washer":"1015.3 psi (7000000 Pa) 131 °F (55 °C) 0.1 m","Ambient Air Temperature for Storage":"-40...158 °F (-40...70 °C)","Ambient Air Temperature for Operation":"-40...158 °F (-40...70 °C)","Number of mushroom-shaped push-buttons":"0","[Uimp] rated impulse withstand voltage":"6 kV IEC 60947-1","Number of contacts as change-over contact":"0","Number of contacts as normally open contact":"1","[Ith] conventional free air thermal current":"10 A IEC 60947-5-1","Number of contacts as normally closed contact":"0"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$15.24","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/51320ab2503fa9ad1d1815d4aafd80e1.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/XALD101H29/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/XALD101H29","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/XALD101H29 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}