{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"XB4BK125M5","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"XB4BK125M5","canonicalUrl":"https://aoctrl.com/schneider/XB4BK125M5","factsUrl":"https://aoctrl.com/api/mcp/products/XB4BK125M5","rawCanonicalId":null},"summary":{"shortDescription":"Illuminated Selector Switch, Poles = 2, Positions = 2, 90°, Panel Mount","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"2.7 in (68 mm)","Width":"1.2 in (30 mm)","Height":"1.9 in (47 mm)","Bulb base":"Integral LED","Head type":"Standard","Standards":"IEC 60947-5-5 JIS C8201-5-1 UL 508 IEC 60947-5-4 IEC 60947-1 IEC 60947-5-1 CSA C22.2 No 14 JIS C8201-1","Light source":"Universal LED","Service life":"100000 h at rated voltage and 25 °C","Bezel material":"Chromium plated metal","Contacts usage":"Standard contacts","Signalling type":"Steady","Surge withstand":"1 kV IEC 61000-4-5","lifecycle_stage":"current","Operating torque":"1.24 lbf.in (0.14 N.m) NO changing electrical state","Operator profile":"Orange standard handle","Positive opening":"With IEC 60947-5-1 appendix K","Range of Product":"Harmony XB4","Shock resistance":"30 gn 18 ms) half sine wave acceleration IEC 60068-2-27 50 gn 11 ms) half sine wave acceleration IEC 60068-2-27","Type of operator":"stay put","Contact operation":"Slow-break","Contacts material":"Silver alloy (Ag/Ni)","Device short name":"XB4","Mounting diameter":"0.9 in (22.5 mm)","Tightening torque":"7.08...10.6 lbf.in (0.8...1.2 N.m) IEC 60947-1","Current Consumption":"14 mA","Device presentation":"Complete product","Shape of screw head":"Cross Philips no 1 Cross pozidriv No 1 Slotted flat Ø 4 mm Slotted flat Ø 5.5 mm","Protective treatment":"TH","Vibration resistance":"5 gn (f= 2...500 Hz) conforming to IEC 60068-2-6","Electrical durability":"1000000 cycles, AC-15, 2 A 230 V 3600 cyc/h 0.5 EN 60947-5-1 appendix C 1000000 cycles, AC-15, 3 A 120 V 3600 cyc/h 0.5 EN 60947-5-1 appendix C 1000000 cycles, AC-15, 4 A 24 V 3600 cyc/h 0.5 EN 60947-5-1 appendix C 1000000 cycles, DC-13, 0.2 A 110 V 3600 cyc/h 0.5 EN 60947-5-1 appendix C 1000000 cycles, DC-13, 0.5 A 24 V 3600 cyc/h 0.5 EN 60947-5-1 appendix C","Mechanical durability":"1000000 cycles","Nbr. of units in pkg.":"1","Supply voltage limits":"195...264 V AC","Electrical reliability":"Λ < 10exp(-6) 5 V 1 mA in clean environment IEC 60947-5-4 Λ < 10exp(-8) 17 V 5 mA in clean environment IEC 60947-5-4","Fixing collar material":"Zamak","Connections - terminals":"Screw clamp terminals, Screw clamp terminals, >= 1 x 0.22 mm² without cable end IEC 60947-1","IK degree of protection":"IK04 conforming to IEC 50102","IP degree of protection":"IP66 IEC 60529 IP67 IP69 IP69K","Electromagnetic emission":"Class B IEC 55011","Short-circuit protection":"10 A cartridge fuse gG IEC 60947-5-1","NEMA degree of protection":"NEMA 13 NEMA 4X","Product or Component Type":"Illuminated selector switch","[Us] rated supply voltage":"230...240 V AC 50/60 Hz","Shape of signaling unit head":"Round","Contacts type and composition":"1 NO + 1 NC","Operator position information":"2 positions 90°","Resistance to fast transients":"2 kV IEC 61000-4-4","Sale per indivisible quantity":"1","[Ui] rated insulation voltage":"600 V 3)IEC 60947-1","Terminals description ISO n°1":"(21-22)NC (13-14)NO","[Ie] rated operational current":"3 A 240 V, AC-15, A600 IEC 60947-5-1 6 A 120 V, AC-15, A600 IEC 60947-5-1 0.1 A 600 V, DC-13, Q600 IEC 60947-5-1 0.27 A 250 V, DC-13, Q600 IEC 60947-5-1 0.55 A 125 V, DC-13, Q600 IEC 60947-5-1 1.2 A 600 V, AC-15, A600 IEC 60947-5-1","Electrical shock protection class":"Class I conforming to IEC 60536","Resistance to high pressure washer":"1015.3 psi (7000000 Pa) 131 °F (55 °C) 0.1 m","Ambient Air Temperature for Storage":"-40...158 °F (-40...70 °C)","Resistance to electromagnetic fields":"9.1 V/m (10 V/m) IEC 61000-4-3","Ambient Air Temperature for Operation":"-40...158 °F (-40...70 °C)","Resistance to electrostatic discharge":"6 kV on contact (on metal parts) IEC 61000-4-2 8 kV in free air (in insulating parts) IEC 61000-4-2","[Uimp] rated impulse withstand voltage":"6 kV IEC 60947-1","[Ith] conventional free air thermal current":"10 A IEC 60947-5-1"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$64.76 – $69.04","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/beb282c61e9b9a9d375a8ae4b07f15b3.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/XB4BK125M5/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/XB4BK125M5","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/XB4BK125M5 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}