{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"XCKT2510N12","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"XCKT2510N12","canonicalUrl":"https://aoctrl.com/schneider/XCKT2510N12","factsUrl":"https://aoctrl.com/api/mcp/products/XCKT2510N12","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric XCKT2510N12 Osiswitch compact limit switch, 1NO-1NC slow make/break, 240 VAC 10 A, IP66/IP67 enclosure, top push rod plunger.","salesMarkdown":"## Compact plunger head, IP67 body The XCKT2510N12: The wide plastic housing is rated NEMA 1/2/4/6/12/13 plus IP66 and IP67, so the same body works on indoor panels and on outdoor or washdown machinery without a separate boot — a meaningful consolidation for panel builders who would otherwise stock a second switch for wet zones. Operating temperature spans -13 to 158 DEG F, covering most factory-floor enclosures without a heater strip or a cold-weather derate on the seal stack. ## Contact rating and what it drives Termination is 1/2 inch NPT conduit entry with screw clamp terminals, matching the standard cable gland on most US-style machine enclosures and accepting the same ferruled conductors used elsewhere in the panel. Total travel is 5 mm against 0.9 mm differential travel — the 5 mm overtravel gives the cam some margin against an over-travel event without bending the plunger, while the short differential travel keeps the snap point close to the actuator face for repeatable position feedback. ## Standards and approvals on record The part is approved to UL 508 and CSA C22.2, and is built to EN/IEC 60204-1 and EN/IEC 60947-5-1 — the IEC 60947-5-1 line covers low-voltage switchgear control devices, so the contact ratings are stated under that standard rather than the older UL 508 alone, which matters for OEMs shipping machinery globally. UPC 78590126954 (12-digit 785901269540) is the factory trace code carried on the box label, the same identifier an incoming-inspection clerk can match against the packing slip without pulling the switch out of its carton. ## Sourcing posture for this code The XCKT body and the Osiswitch head line are still the standard Schneider Electric family for general-duty limit switches, meaning replacement units in the field match the footprint and the actuator pattern — a maintenance spare from this listing bolts back onto the same mounting holes and picks up the same cam profile without a re-tool.","metaTitle":"Schneider XCKT2510N12 Limit Switch, 240VAC 10A, IP66/67","metaDescription":"Schneider XCKT2510N12 Osiswitch limit switch, 1NO-1NC slow make/break, top push rod plunger, IP66/67 enclosure. Sourced to order against an RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Limit Switches"],"specifications":{"UPC":"78590126954","Type":"COMPACT, MODULAR","Model":"XCKT","title":"XCKT2510N12","Approval":"UL 508, CSA C22.2","Category":"General Duty Limit Switches","Enclosure":"NEMA 1/2/4/6/12/13, IP66, IP67","Brand Name":"Osiswitch[R]","description":"SQUARE D XCKT2510N12: LIMIT SWITCH 240VAC 10A PLAST","Sub-Category":"General/Heavy Duty Limit Switch","Total Travel":"5 MM","UPC 12 Digit":"785901269540","Body Material":"WIDE PLASTIC","Contact Rating":"240 VAC 10 AMPERE, 250 VDC 0.27 AMPERE","Operation Type":"SPRING RETURN","Connection Type":"1/2 INCH NPT CONDUIT/SCREW CLAMP TERMINAL","Operating Force":"398 LB-INCH","lifecycle_stage":"current","Actuator/Head Type":"TOP PUSH ROD PLUNGER","Manufacturer Brand":"Square D Co.","Differential Travel":"0.9 MM","Product Description":"Telemecanique XCKT2510N12 Limit Switch 240Vac 10A Plastic","Contact Configuration":"1NO-1NC SLOW MAKE/BREAK","Operating Temperature":"-13 TO 158 DEG F","Additional Information":"APPLICABLE STANDARD EN/IEC 60204-1, EN/IEC 60947-5-1","Full Technical Description":"Compact, Modular Type; 1NO-1NC Slow Make/Break Contact Configuration; 1/2 Inch NPT Conduit/Screw Clamp Terminal Connection Type; Spring Return Operation Type; 240 VAC 10 Ampere, 250 VDC 0.27 Ampere Contact Rating; UL 508, CSA C22.2 Approval; NEMA 1/2/4/6/12/13, IP66, IP67 Enclosure; Wide Plastic Body Material; -13 to 158 Deg F Operating Temperature; 398 lb-Inch Operating Force; 0.9 mm Differential Travel; Top Push Rod Plunger Actuator/Head Type; 5 mm Total Travel; OSISWITCH[R] Brand; Applicable Standard En/Iec 60204-1, En/Iec 60947-5-1; XCKT Model"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$71.09","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/0f2aadd149bf37012512f824664a2786.pdf","sourceUrl":null},"ai":{"faq":[{"question":"What is XCKT2510N12's listed type on the limit-switch line?","answer":"It is listed as a compact, modular type within the XCKT model — the modular descriptor points to a switch body that takes the standard Osiswitch head and contact-block family rather than a one-piece sealed unit."},{"question":"What approvals back the XCKT2510N12 for an OEM machinery build?","answer":"The XCKT2510N12 is approved to UL 508 and CSA C22.2 and is built to EN/IEC 60204-1 and EN/IEC 60947-5-1 — the IEC 60947-5-1 entry in particular ties the contact ratings to the low-voltage switchgear control standard used on globally shipped machinery, not the older UL 508 only."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/XCKT2510N12","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/XCKT2510N12 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}