{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"XPSMC16ZCPACK","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"XPSMC16ZCPACK","canonicalUrl":"https://aoctrl.com/schneider/XPSMC16ZCPACK","factsUrl":"https://aoctrl.com/api/mcp/products/XPSMC16ZCPACK","rawCanonicalId":null},"summary":{"shortDescription":"safety controller XPS-MC - 24 V DC - 16 input - 32 LEDs signalling","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Depth":"6.02 in (153 mm)","Width":"2.9 in (74 mm)","Height":"6.0 in (151.5 mm)","Parity":"Even Modbus No Modbus Odd Modbus","Category":"US1SAF222477","Standards":"IEC 61508 EN 954-1/EN/ISO 13849-1 IEC 61496-1 IEC 60204-1 EN 1760-1/ISO 13856-1 EN 574/ISO 13851 IEC 60947-5-1","Data format":"1 start bit/8 data bits 1 stop bit even or odd 2 stop bits without parity RTU (Remote Terminal Unit) mode","Output type":"2 relays, 2 NO contacts (4 NO total) Solid state, 6, volt-free","Safety level":"Can reach PL e/category 4 EN 954-1/EN/ISO 13849-1 Can reach SIL 3 IEC 61508","Exchange size":"14 words","Response Time":"Configurable : 20 ms or 30 ms with software XPSMCWIN","Type of start":"Configurable","Kit composition":"Set of cage clamp terminals Configuration software CANopen SUB-D female connector 180 Packaging small model for software configuration Safety controller Ethernet cable 2m CANopen SUB-D female connector 90 USB/RS485 converter VDE slot screwdriver 2.5 x 75 mm Set of screw terminals Connection cable Printed packaging label 80 x 50 mm","lifecycle_stage":"mature","Local signalling":"32 LEDs","Method of access":"Slave","Mounting Support":"Mounting plate","Number of inputs":"16","Range of Product":"Preventa Safety automation","Breaking capacity":"2 A 24 V static output circuit 1.5 A 24 V DC-13)50 ms relay output","Function of module":"Dynamic monitoring of hydraulic valves on linear presses Eccentric press Emergency stop monitoring, with or without time delay, 1 or 2-channel wiring Enabling switch monitoring, 2 or 3 contacts Foot switch monitoring Guard monitoring for injection presses and blowing machines Guard monitoring with 1 or 2 limit switches Hydraulic press Magnetic switch monitoring category 4 EN/IEC 61496 Monitoring safety stop at top dead centre on eccentric press category 3 EN 574/ISO 13851 Muting function of light curtains Position selector Safety mat monitoring Safety time delays Shaft/chain breaking monitor Zero speed detection Light curtain monitoring category 4 IEC 61496 Two-hand control category 3 EN 574/ISO 13851","Safety module name":"XPSMC","Number of addresses":"1...127 CANopen 1...247 Modbus","Safety use category":"Category 4 maximum EN 954-1/EN/ISO 13849-1 PLE maximum ISO 13849-1 SIL 3 maximum IEC 61508","Input protection type":"External fuse 16 A","Nbr. of units in pkg.":"1","Associated fuse rating":"16 A gL power supply 4 A gL relay output 6 A fast blow relay output","Minimum output current":"10 mA relay output","Minimum output voltage":"17 V relay output","Output thermal current":"4 A for both outputs simultaneously 6 A for 1 output and 2 A for the other relay output","Power Consumption in W":"12 W","IP degree of protection":"IP20 conforming to IEC 60529","Maximum line resistance":"100 Ohm <6561.7 ft (2000 m)","Product or Component Type":"Kit configurable safety controller","Supported modbus function":"01 8-bit output data/32-bit input data 02 32-bit input data/8-bit output data 03 information and errors","[Us] Rated Supply Voltage":"24 V DC - 20...20 %","Communication port protocol":"CANopen 1 SUB-D 9-pin male, serial link 20 kbps, 50 kbps, 125 kbps, 250 kbps, 500 kbps, 800 kbps or 1 Mbps Modbus 1 RJ45, serial link 1200 bps, 2400 bps, 4800 bps, 9600 bps or 19200 bps","[Uc] control circuit voltage":"28.8 V","[Ui] rated insulation voltage":"300 V 2)IEC 60647-5-1, DIN VDE 0110 part 1","Ambient Air Temperature for Storage":"-13...185 °F (-25...85 °C)","Synchronisation time between inputs":"Depending on configuration selected","Ambient Air Temperature for Operation":"14...131 °F (-10...55 °C)","[Uimp] rated impulse withstand voltage":"4 kV III IEC 60647-5-1, DIN VDE 0110 part 1","[Ith] conventional free air thermal current":"16 A relay output 6.5 A static output circuit"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/77bf64ca715fa9de7f98f88d42ee132d.pdf","sourceUrl":"https://www.se.com/ie/en/product/XPSMC16ZCPACK/safety-controller-xpsmc-24-v-dc-16-input-32-leds-signalling/","alternativesUrl":"https://aoctrl.com/api/mcp/products/XPSMC16ZCPACK/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/XPSMC16ZCPACK","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/XPSMC16ZCPACK when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}