{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"XPSMC16ZPPACK","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"XPSMC16ZPPACK","canonicalUrl":"https://aoctrl.com/schneider/XPSMC16ZPPACK","factsUrl":"https://aoctrl.com/api/mcp/products/XPSMC16ZPPACK","rawCanonicalId":null},"summary":{"shortDescription":"safety controller XPS-MC - 24 V DC - 16 input - 32 LEDs signalling","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Depth":"6.02 in (153 mm)","Width":"2.9 in (74 mm)","Height":"6.0 in (151.5 mm)","Parity":"Even Modbus No Modbus Odd Modbus","Category":"22477-SAFETY MODULES (PREVENTA)","Standards":"IEC 61508 EN/IEC 60947-5-1 EN/IEC 60204-1 EN/IEC 61496-1 EN 954-1/EN/ISO 13849-1 EN 1760-1/ISO 13856-1 EN 574/ISO 13851","Data format":"1 start bit/8 data bits 1 stop bit even or odd 2 stop bits without parity RTU (Remote Terminal Unit) mode","Output type":"2 relays, 2 NO contacts (4 NO total) Solid state, 6, volt-free","Safety level":"Can reach PL e/category 4 EN 954-1/EN/ISO 13849-1 Can reach SIL 3 IEC 61508","Exchange size":"14 words","Response Time":"Configurable : 20 ms or 30 ms with software XPSMCWIN","Type of start":"Configurable","Kit composition":"Safety controller Set of screw terminals Connection cable Printed packaging label 80 x 50 mm Configuration software USB/RS485 converter Profibus connectors Set of cage clamp terminals VDE slot screwdriver 2.5 x 75 mm Packaging small model for software configuration Ethernet cable 2m","lifecycle_stage":"mature","Local signalling":"32 LEDs","Method of access":"Slave","Mounting Support":"Mounting plate","Number of inputs":"16","Range of Product":"Preventa Safety automation","Breaking capacity":"2 A 24 V static output circuit 1.5 A 24 V DC-13)50 ms relay output","Function of module":"Dynamic monitoring of hydraulic valves on linear presses Eccentric press Emergency stop monitoring, with or without time delay, 1 or 2-channel wiring Enabling switch monitoring, 2 or 3 contacts Foot switch monitoring Guard monitoring for injection presses and blowing machines Guard monitoring with 1 or 2 limit switches Hydraulic press Magnetic switch monitoring Monitoring safety stop at top dead centre on eccentric press Muting function of light curtains Position selector Safety mat monitoring Safety time delays Shaft/chain breaking monitor Zero speed detection Light curtain monitoring category 4 EN/IEC 61496 Two-hand control category 3 EN 574/ISO 13851","Safety module name":"XPSMC","Number of addresses":"1...125 Profibus 1...247 Modbus","Safety use category":"Category 4 maximum EN 954-1/EN/ISO 13849-1 PLE maximum EN/ISO 13849-1 SIL 3 maximum IEC 61508","Input protection type":"External fuse 16 A","Nbr. of units in pkg.":"1","Associated fuse rating":"16 A gL power supply 4 A gL relay output 6 A fast blow relay output","Minimum output current":"10 mA relay output","Minimum output voltage":"17 V relay output","Output thermal current":"4 A for both outputs simultaneously 6 A for 1 output and 2 A for the other relay output","Power Consumption in W":"12 W","IP degree of protection":"IP20 conforming to EN/IEC 60529","Maximum line resistance":"100 Ohm <6561.7 ft (2000 m)","Product or Component Type":"Kit configurable safety controller","Supported modbus function":"01 8-bit output data/32-bit input data 02 32-bit input data/8-bit output data 03 information and errors","[Us] Rated Supply Voltage":"24 V DC - 20...20 %","Communication port protocol":"Modbus 1 RJ45, serial link 1200 bps, 2400 bps, 4800 bps, 9600 bps or 19200 bps Profibus 1 SUB-D 9-pin female, serial link 12 Mbps","[Uc] control circuit voltage":"28.8 V","[Ui] rated insulation voltage":"300 V 2)IEC 60647-5-1, DIN VDE 0110 part 1","Ambient Air Temperature for Storage":"-13...185 °F (-25...85 °C)","Synchronisation time between inputs":"Depending on configuration selected","Ambient Air Temperature for Operation":"14...131 °F (-10...55 °C)","[Uimp] rated impulse withstand voltage":"4 kV III IEC 60647-5-1, DIN VDE 0110 part 1","[Ith] conventional free air thermal current":"16 A relay output 6.5 A static output circuit"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f43ce946aba7ee2dd394debcadebfe59.pdf","sourceUrl":"https://www.se.com/us/en/product/XPSMC16ZPPACK/safety-controller-xpsmc-24-v-dc-16-input-32-leds-signalling/","alternativesUrl":"https://aoctrl.com/api/mcp/products/XPSMC16ZPPACK/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/XPSMC16ZPPACK","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/XPSMC16ZPPACK when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}