{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"XPSMCMER0002G","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"XPSMCMER0002G","canonicalUrl":"https://aoctrl.com/schneider/XPSMCMER0002G","factsUrl":"https://aoctrl.com/api/mcp/products/XPSMCMER0002G","rawCanonicalId":null},"summary":{"shortDescription":"Schneider XPSMCMER0002G Modicon Mcm — now discontinued, supplied from remaining surplus and broker stock.","salesMarkdown":"## Overview The XPSMCMER0002G is a Preventa safety module from the Modicon MCM range, delivering 2 relay outputs (2 NO + 1 NC) rated for safety functions up to SIL 3 per IEC 61508, PL e per ISO 13849-1, and Category 4. It runs on a 24 VDC supply and terminates via spring-clamp terminals on a removable block. The module is rated for 10 gn shock (16 ms, 1000 shocks per axis) per IEC 61496-1, making it suitable for machine-mounted applications with high vibration. Compared to the XPSMCMER0008, which provides 8 relay outputs (8 NO + 4 NC) with screw terminals, the XPSMCMER0002G is the compact choice for smaller safety actuator groups. The 2-relay variant uses spring-clamp terminals and a removable block, while the 8-relay version uses captive screw terminals and a fixed block.","metaTitle":"Schneider XPSMCMER0002G Modicon MCM safety relay, 2 NO + 1 NC, SIL 3","metaDescription":"Schneider XPSMCMER0002G Preventa safety module: 2 relay outputs (2 NO + 1 NC), 24 VDC, SIL 3 / PL e / Cat 4, spring terminals, IP20, 10 gn shock.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Depth":"4.5 in (114.5 mm)","Width":"0.9 in (22.5 mm)","Height":"3.9 in (99 mm)","Category":"US1SAF222477","Standards":"IEC 62061 ISO 13849-1 IEC 61800-5-1 IEC 61508","Insulation":"250 V AC between power supply and housing IEC 61800-5-1","Output type":"Relay, 2 NO + 1 NC, volt-free","Safety level":"Can reach category 4 ISO 13849-1 Can reach PL = e ISO 13849-1 Can reach SIL 3 IEC 61508 SILCL 3 IEC 62061","Service Life":"20 year(s)","Quality labels":"CE","Switching time":"12 ms","lifecycle_stage":"mature","Local signalling":"1 LED green PWR power ON 1 LED green RUN RUN (status) 1 LED red E IN internal error 1 LED red E EX external error 2 LEDs orange ADDR node address 1 LED green/red RELAY K1 relay contact","Mounting support":"Omega 35 mm DIN rail EN 50022","Pollution degree":"2","Quantity per Set":"1","Range of Product":"Preventa Safety automation","Shock resistance":"10 gn 16 ms 1000 shocks on each axis)IEC 61496-1","Device short name":"XPSMCM","Number of Outputs":"2 relay","Relative Humidity":"10...95 %","Switching voltage":"10 V DC","Function of module":"Monitoring safety actuators relay output","Cable cross section":"0.0003...0.004 in² (0.2...2.5 mm²) - AWG 24...AWG 14 flexible without cable end 0.0004...0.004 in² (0.25...2.5 mm²) - AWG 23...AWG 14 flexible with cable end, with bezel 0.0004...0.004 in² (0.25...2.5 mm²) - AWG 23...AWG 14 flexible with cable end, without bezel 0.0003...0.004 in² (0.2...2.5 mm²) - AWG 24...AWG 14 solid without cable end 0.0008...0.002 in² (0.5...1 mm²) - AWG 20...AWG 18 flexible with cable end, with double bezel","Overvoltage category":"II","Vibration resistance":"+/-0.35 mm (f= 10...55 Hz) conforming to IEC 61496-1","Electrical Connection":"Spring terminal","Electrical durability":"20000000 cycles","Mechanical durability":"20000000 cycles","Nbr. of units in pkg.":"1","Associated fuse rating":"3.5 A, slow-blow","Connections - terminals":"1 spring clamp terminals, removable terminal block 2 spring clamp terminals, removable terminal block","IP degree of protection":"IP20","Safety reliability data":"B10d = 300000 AC-15 230 V, , B10d = 750000 AC-15 230 V, , B10d = 10000000 DC-13 24 V, , <2 A ISO 13849-1","Maximum switching current":"6 A","Maximum switching voltage":"400 V AC 250 V DC","Minimum Switching Current":"20 mA","Number of terminal blocks":"4","Product or Component Type":"Safe relay output module","[Us] rated supply voltage":"24 V - 20...20 % DC","Integrated connection type":"Not connected to backplane expansion bus","Electromagnetic compatibility":"Electrostatic discharge immunity test - test level: 6 kV (on contact) conforming to IEC 61000-4-2 Electrostatic discharge immunity test - test level: 20 kV (on air) conforming to IEC 61000-4-2 Susceptibility to electromagnetic fields - test level: 10 V/m (80...1000 MHz) conforming to IEC 61000-4-3 Susceptibility to electromagnetic fields - test level: 30 V/m (1.4 GHz...2 GHz) conforming to IEC 61000-4-3","Maximum power dissipation in W":"3 W","Ambient Air Temperature for Storage":"-4...185 °F (-20...85 °C)","Ambient Air Temperature for Operation":"14...131 °F (-10...55 °C)","[Uimp] rated impulse withstand voltage":"4 kV IEC 61800-5-1"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$732.60","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d84e56d8338c3fc40957591dff0f3f00.pdf","sourceUrl":"https://www.se.com/za/en/product/XPSMCMER0002G/2-safety-relay-outputs-expansion-module-with-spring-term/","alternativesUrl":"https://aoctrl.com/api/mcp/products/XPSMCMER0002G/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/XPSMCMER0002G","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/XPSMCMER0002G when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}