{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"XPSUAB31CC","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"XPSUAB31CC","canonicalUrl":"https://aoctrl.com/schneider/XPSUAB31CC","factsUrl":"https://aoctrl.com/api/mcp/products/XPSUAB31CC","rawCanonicalId":null},"summary":{"shortDescription":"safety module, Harmony XPSU, potential free 2 NC, NO NC, 2 PNP, 48 to 240V AC or DC, spring","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"4.7 in (120 mm)","Width":"0.9 in (22.5 mm)","Height":"3.9 in (100 mm)","Category":"US1SAF222477","Standards":"IEC 60947-5-1 IEC 61508-1 functional safety standard IEC 61508-2 functional safety standard IEC 61508-3 functional safety standard IEC 61508-4 functional safety standard IEC 61508-5 functional safety standard IEC 61508-6 functional safety standard IEC 61508-7 functional safety standard ISO 13849-1 functional safety standard IEC 62061 functional safety standard","Safety level":"Can reach PL = c ISO 13849-1 Can reach SILCL 1 IEC 62061 Can reach SIL 1 IEC 61508","Safety Inputs":"1 safety input 24 V DC 5 mA","Type of start":"Automatic/manual/monitored","Safety Outputs":"1 C/O","Control Outputs":"2 on/off configurable pulsed output","lifecycle_stage":"unknown","Local signalling":"LED (green) for power ON LED (red) for error LED (yellow) for start LED (yellow) for safety status LED (yellow) for safety input S12 LED (yellow) for safety input S13","Mounting Support":"35 mm symmetrical DIN rail","Range of Product":"Harmony Safety Automation","Input/output type":"Semiconductor pulsed diagnostic output 24 V DC, 20 mA Z1, not safety-related","Relative Humidity":"5...95 % non-condensing","Function of module":"Emergency stop monitoring 1-channel wiring Guard monitoring 1-channel wiring Monitoring 1 PNP sensor Monitoring two-hand control station type IIIA Magnetic switch monitoring Light curtain monitoring RFID switch Monitoring of electro-sensitive protection equipment (ESPE) Proximity sensor monitoring","Safety module name":"XPSUAB","Input compatibility":"Normally closed circuit ISO 14119 XC limit switch ISO 14119 Mechanical contact ISO 14119 Normally closed circuit ISO 13850 Antivalent pair ISO 14119 OSSD pair IEC 61496-1-2 Two-hand control EN 574/ISO 13851-III A 3-wire proximity sensors PNP","Input protection type":"Internal, electronic","Nbr. of units in pkg.":"1","Associated fuse rating":"6 A gG relay output IEC 60947-1","Minimum output current":"10 mA relay output","Minimum output voltage":"15 V relay output","Power consumption in W":"2.0 W 48 V DC","Connections - terminals":"Removable spring terminal block, 0.2...2.5 mm² solid or flexible Removable spring terminal block, 0.25...2.5 mm² flexible with ferrule single conductor Removable spring terminal block, 0.2...1.5 mm² solid or flexible twin conductor Removable spring terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with bezel Removable spring terminal block, 2 x 0.5...1.5 mm² flexible with ferrule with cable end, with bezel","Electrical circuit type":"NC pair PNP pair Antivalent pair OSSD pair","IP degree of protection":"IP20 terminals)IEC 60529 IP40 housing)IEC 60529 IP54 mounting area)IEC 60529","Maximum Wire Resistance":"500 Ohm","Power consumption in VA":"6.5 VA 240 V AC 50/60 Hz","Safety reliability data":"MTTFd >= 30 years ISO 13849-1 Dcavg < 60 % ISO 13849-1 PFHd = 1177E-09 1/h ISO 13849-1 HFT = 0 IEC 62061 PFHd = 1177E-09 1/h IEC 62061 SFF > 60% IEC 62061 HFT=0 IEC 61508-1 PFHd = 1177E-09 1/h IEC 61508-1 SFF > 60% IEC 61508-1 Type = B IEC 61508-1","Product or Component Type":"Safety module","Safety module application":"For electrical monitoring of two-hand control stations For application with safety switchover contact For emergency stop, guard and light curtain monitoring Monitoring antivalent contacts","[Us] Rated Supply Voltage":"48...240 V AC/DC - 10...10 %","[Ui] rated insulation voltage":"250 V 2)IEC 60947-1","[Ie] rated operational current":"5 A AC-1 for normally open relay contact 3 A AC-15 for normally open relay contact 5 A DC-1 for normally open relay contact 3 A DC-13 for normally open relay contact 3 A AC-1 for normally closed relay contact 1 A AC-15 for normally closed relay contact 2 A DC-1 for normally closed relay contact 1 A DC-13 for normally closed relay contact","Maximum response time on input open":"20 ms","Synchronisation time between inputs":"0.5 s 2.2 s","Ambient Air Temperature for Operation":"-13...131 °F (-25...55 °C)","[Uimp] rated impulse withstand voltage":"4 kV II IEC 60947-1","[Ith] conventional free air thermal current":"3 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c88dfcb599ae8c890543f6d20d6f820b.pdf","sourceUrl":"https://www.se.com/au/en/product/XPSUAB31CC/safety-module-harmony-xpsu-potential-free-2-nc-no-nc-2-pnp-48-to-240v-ac-or-dc-spring/","alternativesUrl":"https://aoctrl.com/api/mcp/products/XPSUAB31CC/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/XPSUAB31CC","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/XPSUAB31CC when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}