{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"XPSUAK32AC","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"XPSUAK32AC","canonicalUrl":"https://aoctrl.com/schneider/XPSUAK32AC","factsUrl":"https://aoctrl.com/api/mcp/products/XPSUAK32AC","rawCanonicalId":null},"summary":{"shortDescription":"safety module, Harmony XPSU, Cat 4, features XPSUAF with PNP or NPN, safety mat, 48 to 240V AC or DC, spring","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"4.7 in (120 mm)","Width":"0.9 in (22.5 mm)","Height":"3.9 in (100 mm)","Category":"US1SAF222477","Standards":"IEC 60947-5-1 IEC 61508-1 functional safety standard IEC 61508-2 functional safety standard IEC 61508-3 functional safety standard IEC 61508-4 functional safety standard IEC 61508-5 functional safety standard IEC 61508-6 functional safety standard IEC 61508-7 functional safety standard ISO 13849-1 functional safety standard IEC 62061 functional safety standard","Safety level":"Can reach PL e/category 4 for normally open relay contact ISO 13849-1 Can reach SILCL 3 for normally open relay contact IEC 62061 Can reach SIL 3 for normally open relay contact IEC 61508 Can reach PL c/category 1 for normally closed relay contact ISO 13849-1 Can reach SILCL 1 for normally closed relay contact IEC 62061 Can reach SIL 1 for normally closed relay contact IEC 61508","Safety Inputs":"2 safety input 24 V DC 5 mA","Type of start":"Automatic/manual/monitored","Safety Outputs":"2 NO + 1 NC","Control Outputs":"3 on/off configurable pulsed output","lifecycle_stage":"unknown","Mounting Support":"35 mm symmetrical DIN rail","Range of Product":"Harmony Safety Automation","Input/output type":"Semiconductor pulsed diagnostic output 24 V DC, 20 mA Z1, not safety-related","Relative Humidity":"5...95 % non-condensing","Function of module":"Emergency stop button with 2 NC contacts Guard monitoring with 1 or 2 limit switches Monitoring 2 PNP sensors Magnetic switch monitoring Light curtain monitoring RFID switch Monitoring of electro-sensitive protection equipment (ESPE) Sensing mat/edges Proximity sensor monitoring Monitoring 1 PNP + 1 NPN sensor","Safety module name":"XPSUAK","Input compatibility":"Normally closed circuit ISO 14119 XC limit switch ISO 14119 Mechanical contact ISO 14119 Normally closed circuit ISO 13850 Antivalent pair ISO 14119 OSSD pair IEC 61496-1-2 3-wire proximity sensors PNP","Input protection type":"Internal, electronic","Nbr. of units in pkg.":"1","Associated fuse rating":"10 A gG NO relay output circuit IEC 60947-1","Minimum output current":"10 mA relay output","Minimum output voltage":"12 V relay output","Power consumption in W":"3.0 W 48 V DC","Connections - terminals":"Removable spring terminal block, 0.2...2.5 mm² solid or flexible Removable spring terminal block, 0.25...2.5 mm² flexible with ferrule single conductor Removable spring terminal block, 0.2...1.5 mm² solid or flexible twin conductor Removable spring terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with bezel Removable spring terminal block, 2 x 0.5...1.5 mm² flexible with ferrule with cable end, with bezel","Electrical circuit type":"NC pair PNP pair Antivalent pair OSSD pair","IP degree of protection":"IP20 terminals)IEC 60529 IP40 housing)IEC 60529 IP54 mounting area)IEC 60529","Maximum Wire Resistance":"500 Ohm","Power consumption in VA":"6.5 VA 240 V AC 50/60 Hz","Safety reliability data":"MTTFd > 30 years ISO 13849-1 Dcavg >= 99 % ISO 13849-1 PFHd = 1.61E-09 ISO 13849-1 HFT = 1 IEC 62061 PFHd = 1.61E-09 IEC 62061 SFF > 99% IEC 62061 HFT = 1 IEC 61508-1 PFHd = 1.61E-09 IEC 61508-1 SFF > 99% IEC 61508-1 Type = B IEC 61508-1","Product or Component Type":"Safety module","Safety module application":"Monitoring antivalent contacts For emergency stop, guard and light curtain monitoring Monitoring of pressure-sensitive 4-wire protective devices","[Us] Rated Supply Voltage":"48...240 V AC/DC - 10...10 %","[Ui] rated insulation voltage":"250 V 2)IEC 60947-1","[Ie] rated operational current":"5 A AC-1 for normally open relay contact 3 A AC-15 for normally open relay contact 5 A DC-1 for normally open relay contact 3 A DC-13 for normally open relay contact 3 A AC-1 for normally closed relay contact 1 A AC-15 for normally closed relay contact 3 A DC-1 for normally closed relay contact 1 A DC-13 for normally closed relay contact","Synchronisation time between inputs":"0.5 s 2 s 4 s","Ambient Air Temperature for Operation":"-13...131 °F (-25...55 °C)","[Uimp] rated impulse withstand voltage":"4 kV II IEC 60947-1","[Ith] conventional free air thermal current":"8 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e668ecfa5b13274a65de5f477ef8a679.pdf","sourceUrl":"https://www.se.com/au/en/product/XPSUAK32AC/safety-module-harmony-xpsu-cat-4-features-xpsuaf-with-pnp-or-npn-safety-mat-48-to-240v-ac-or-dc-spring/","alternativesUrl":"https://aoctrl.com/api/mcp/products/XPSUAK32AC/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/XPSUAK32AC","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/XPSUAK32AC when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}