{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"XSAV11801EX","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"XSAV11801EX","canonicalUrl":"https://aoctrl.com/schneider/XSAV11801EX","factsUrl":"https://aoctrl.com/api/mcp/products/XSAV11801EX","rawCanonicalId":null},"summary":{"shortDescription":"Schneider OsiSense XS XSAV11801EX Inductive Proximity Sensor, M30 x 1.5, 2-wire AC/DC, NC, 0-8 mm, IP67, ATEX Zone 22.","salesMarkdown":"## Integrator field note The XSAV11801EX is a cylindrical M30 inductive proximity sensor – 2-wire AC/DC, NC output, 0-8 mm operating zone. The 9-second run-up delay at power-up is deliberate: it masks inrush on systems that also count a rotation stop after energising. Switching frequency tops at 100 Hz, so minimum target dwell is 10 ms; slower than a standard prox, but sized for rotation-monitoring applications where target speeds are modest. ## Lifecycle & sourcing posture The XSAV11801EX is classified as current lifecycle in the OsiSense XS range. ## Mounting & wiring checklist M30 x 1.5 locknut or weld-in boss; tighten to 20 N·m max (brass body, no thread locker needed). Cable is 2 x 0.34 mm², 2 m long – route outside the sensing face to avoid metal debris pickup. The 2-wire AC/DC circuit sinks 5-200 mA DC or 5-350 mA AC; voltage drop ≤5.7 V at closed state. Residual leakage ≤1.5 mA open – enough to hold off a PLC input in sink mode but may pull a relay that requires >1.5 mA keep-alive. Test the load impedance before commissioning for non-standard drops.","metaTitle":"Schneider XSAV11801EX Proximity M30 IP67 Ex","metaDescription":"XSAV11801EX inductive proximity sensor, M30 x 1.5, 2-wire AC/DC, NC, 0-8 mm, IP67, ATEX Zone 22 (II2 D Ex tb IIIC T85°C Db). Current lifecycle. RFQ for supply.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Proximity Sensors"],"specifications":{"Size":"81 mm","title":"XSAV11801EX","Height":"1.18 in (30 mm)","Length":"3.19 in (81 mm)","Marking":"II2 D-Ex tb IIIC T85°C Db IP67","Category":"22486 - SENSORS, proxIMITY","Material":"Metal","Body type":"Fixed","Standards":"EN/IEC 60079-0 , EN/IEC 60079-31","Status LED":"1 LED red output state","Sensor name":"XSA","Sensor type":"Inductive proximity sensor","Series name":"Application","Thread type":"M30 x 1.5","description":"Rotation monitoring hazard area - M30 - Sn10mm - 6..150c/mn - cable 2m","Cable length":"6.56 ft (2 m)","Voltage drop":"<= 5.7 Vat closed state","Sensor design":"Cylindrical M30","Detection face":"Frontal","Front material":"PPS","Operating zone":"0...0.31 in (0...8 mm)","Product weight":"0.66 lb(US) (0.3 kg)","Repeat accuracy":"3% of Sr","Shipping weight":"1kg","Threaded length":"2.24 in (57 mm)","lifecycle_stage":"current","Range of product":"OsiSense XS","Residual current":"<= 1.5 mA open state","Wiring technique":"2-wire","Cable composition":"2 x 0.34 mm²","Device application":"Rotation monitoring","Enclosure material":"Nickel plated brass","Differential travel":"3...15% of Fr","Output circuit type":"AC/DC","Switching frequency":"<= 100 Hz","Nbr. of units in pkg.":"1","Supply voltage limits":"20...264 V AC/DC","Type of output signal":"Discrete","IP degree of protection":"IP67 conforming to IEC 60529","Discrete output function":"1 NC","Run-up delay at power-up":"9 s standard","Switching capacity in mA":"5...200 mA DC , 5...350 mA AC","Wire insulation material":"PvR","[Us] rated supply voltage":"24...240 V AC 50/60 Hz , 24...210 V DC","Adjustable frequency range":"6...150 cyc/mn","[Sn] nominal sensing distance":"0.39 in (10 mm)","Detector flush mounting acceptance":"Flush mountable","Ambient air temperature for storage":"-13...158 °F (-25...70 °C)","Ambient air temperature for operation":"-4...140 °F (-20...60 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$160.00","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a927686edda0ad57ea926f9f7176063a.pdf","sourceUrl":null},"ai":{"faq":[{"question":"Will XSAV11801EX drop into a panel wired for XSAV11801L05 without rewiring?","answer":"Yes. Both use the same M30 thread, 2-wire AC/DC circuit, and 2 m cable. Verify the output logic is NC (both are) and the supply range matches. No wiring changes needed unless the zone classification requires the Ex-certified variant."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/XSAV11801EX","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/XSAV11801EX when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}