{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"XT4HU3250FFL000XXX","brand":"ABB","brandSlug":"abb","productSlug":"XT4HU3250FFL000XXX","canonicalUrl":"https://aoctrl.com/abb/XT4HU3250FFL000XXX","factsUrl":"https://aoctrl.com/api/mcp/products/XT4HU3250FFL000XXX","rawCanonicalId":null},"summary":{"shortDescription":"ABB XT4H series molded case circuit breaker, order code XT4HU3250FFL000XXX, 250 A, 600 VAC, 3-pole, with 250 EKIP LSI electronic trip unit, F F UL/CSA.","salesMarkdown":"## 250 A, 600 VAC, 3-Pole — XT4H Frame with EKIP LSI Trip The ABB XT4HU3250FFL000XXX is a molded case circuit breaker in the XT4H frame, rated 250 A continuous at 600 VAC, 3-pole, with the 250 EKIP LSI electronic trip unit. The LSI designation means the trip provides Long-time, Short-time, and Instantaneous protection curves — adjustable for selective coordination in a distribution panel. The F F suffix indicates UL/CSA certification, so this breaker is accepted in North American panelboards and switchgear without additional listing work. Mounts in a standard ABB XT4 draw-out or fixed cradle; the frame accepts plug-in or fixed connections depending on the base ordered separately. The 3-pole footprint occupies one 3-pole space in a distribution panel. Torque terminal connections to the values stamped on the breaker nameplate — the EKIP trip unit draws its power from the line-side current transformers, so no auxiliary control power is needed for the protection functions. ## What the 250 A Rating Means for Your Application In a feeder circuit, size the upstream transformer or bus for at least 250 A; for motor branch circuits, the breaker must be coordinated with the motor full-load current per NEC 430. The EKIP LSI trip unit allows the short-time pickup and delay to be set so the breaker holds through a downstream fault long enough for the branch breaker to clear — selective coordination without nuisance tripping.","metaTitle":"ABB XT4HU3250FFL000XXX Molded Case Breaker, 250A, 600VAC, 3P","metaDescription":"ABB XT4HU3250FFL000XXX molded case circuit breaker, 250 A, 600 VAC, 3-pole, XT4H frame with 250 EKIP LSI trip unit. Current lifecycle stage, sourced to order. Request a quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":[],"specifications":{"Poles":"3","Current":"250 A","Product Type":"Breaker, Molded Case","Product Status":"Active"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2336d4d6416049d1b6651ce236d18310.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/XT4HU3250FFL000XXX/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/XT4HU3250FFL000XXX","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/XT4HU3250FFL000XXX when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}