{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"XT4SU3100FGGB00XXX","brand":"ABB","brandSlug":"abb","productSlug":"XT4SU3100FGGB00XXX","canonicalUrl":"https://aoctrl.com/abb/XT4SU3100FGGB00XXX","factsUrl":"https://aoctrl.com/api/mcp/products/XT4SU3100FGGB00XXX","rawCanonicalId":null},"summary":{"shortDescription":"ABB XT4S 250 molded case circuit breaker, Ekip LSI electronic trip unit, 100 A continuous, 3-pole, UL/CSA listed, order code XT4SU3100FGGB00XXX.","salesMarkdown":"The ABB XT4SU3100FGGB00XXX is a 3-pole molded case circuit breaker from the XT4S 250 frame, fitted with an Ekip LSI electronic trip unit rated at 100 A continuous. It carries UL and CSA approvals, so it slots directly into North American panelboards and switchgear without a separate fuse or coordination study for the branch circuit. The 100 A continuous rating on the Ekip LSI trip unit sets the long-time pickup; the LSI designation means it provides adjustable long-time, short-time, and instantaneous protection — not just magnetic-only. That matters for feeder circuits where you need selectivity with downstream breakers: the short-time delay lets a fault ride through long enough for the closest breaker to clear first, keeping the rest of the panel live. The XT4S 250 frame itself is a compact molded case design that mounts in standard panelboard or switchgear cubicle cutouts. UL 489 listing covers it for branch-circuit protection in North America; CSA C22.2 No. 5 covers Canadian installations. No additional agency marks needed for most industrial and commercial jobs.","metaTitle":"ABB XT4SU3100FGGB00XXX XT4S 250 EKIPLSI, 100A, 3P, UL/CSA","metaDescription":"ABB XT4S 250 molded case circuit breaker, Ekip LSI trip unit, 100 A, 3-pole, UL/CSA listed. Lifecycle stage current — sourced to order. Request quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"lifecycle_stage":"current"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/XT4SU3100FGGB00XXX/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy XT4SU3100FGGB00XXX?","answer":"We source it through independent distribution and quote it to order against an RFQ. Availability and current pricing are confirmed at quote time."},{"question":"What is the closest alternative to XT4SU3100FGGB00XXX in the same family?","answer":"Within the XT4S 250 frame, the closest alternative would be a variant with a different trip unit or current rating — for example, an Ekip G (ground-fault) trip or a higher/lower amp setting. The frame and pole count are the same, but the trip curve and protection functions differ. No pin-compatible drop-in exists because the trip unit is integral to the breaker."},{"question":"What compliance documentation does ABB provide for this breaker?","answer":"ABB provides UL and CSA certification for this model, as indicated in the description. RoHS and REACH declarations are standard for current-production ABB molded case breakers, but specific documentation should be requested at quote time to confirm it matches your compliance requirements."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/XT4SU3100FGGB00XXX","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/XT4SU3100FGGB00XXX when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}