{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"XT6HU3800BFF000XXX","brand":"ABB","brandSlug":"abb","productSlug":"XT6HU3800BFF000XXX","canonicalUrl":"https://aoctrl.com/abb/XT6HU3800BFF000XXX","factsUrl":"https://aoctrl.com/api/mcp/products/XT6HU3800BFF000XXX","rawCanonicalId":null},"summary":{"shortDescription":"ABB XT6HU3800BFF000XXX, Molded Case Circuit Breaker, XT6H frame, 800 A, 600 VAC, 3-pole, TMA trip unit.","salesMarkdown":"## Molded case breaker, 800 A, 600 VAC, 3-pole, TMA trip The ABB XT6HU3800BFF000XXX is a 3-pole molded case circuit breaker in the XT6H frame, rated 800 A at 600 VAC. The TMA trip unit provides thermal-magnetic protection with a fixed magnetic pickup for short-circuit and a thermal element for overload — a common choice for feeder protection in distribution panels where coordination with downstream breakers is needed. The 800 A continuous rating at 600 VAC places this MCCB in the high-current tier for industrial distribution — sized for main feeders feeding multiple downstream subpanels or large motor control centers. The 3-pole configuration covers three-phase systems. The TMA trip unit is a thermal-magnetic design; the 'M' indicates a fixed magnetic trip setting, so it is not field-adjustable for short-circuit pickup. That matters for coordination studies: if you need adjustable magnetic pickup, you would look at the electronic trip versions in the same XT6 family.","metaTitle":"ABB XT6HU3800BFF000XXX Molded Case Breaker, 800A 600VAC 3P","metaDescription":"ABB XT6HU3800BFF000XXX molded case circuit breaker, 800 A, 600 VAC, 3-pole, TMA trip unit. Current production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Amps":"800","Poles":"3","title":"XT6HU3800BFF000XXX","Volts AC":"600","description":"Breaker, Molded Case, XT6H, 800A, 600VAC, 3P, SACE, TMax, TMA Trip Unit|Breaker, Molded Case, XT6H, 800 Amp, 600 Volt AC, 3-Pole, SACE, TMax, TMA Trip Unit","lifecycle_stage":"current"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/eb15f683a1abb63afc0cc5d00f8cf345.pdf","sourceUrl":null},"ai":{"faq":[{"question":"What is XT6HU3800BFF000XXX's listed amps?","answer":"The continuous current rating is 800 A."},{"question":"What is XT6HU3800BFF000XXX's voltage rating?","answer":"The voltage rating is 600 VAC."},{"question":"What is the pole configuration of XT6HU3800BFF000XXX?","answer":"It is a 3-pole breaker, suitable for three-phase systems."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/abb/XT6HU3800BFF000XXX","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/XT6HU3800BFF000XXX when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}