{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"XT6HU3800DFF000XXX","brand":"ABB","brandSlug":"abb","productSlug":"XT6HU3800DFF000XXX","canonicalUrl":"https://aoctrl.com/abb/XT6HU3800DFF000XXX","factsUrl":"https://aoctrl.com/api/mcp/products/XT6HU3800DFF000XXX","rawCanonicalId":null},"summary":{"shortDescription":"ABB Tmax XT6H series, XT6HU3800DFF000XXX, Molded Case Circuit Breaker, 800A, 3-pole, 600VAC, 800A frame, fixed trip.","salesMarkdown":"## The 800A workhorse for your main feeder That 800 A rating means it handles the full load current of a large motor control center or a main distribution panel without needing a separate disconnect. The fixed-trip design means the thermal-magnetic trip unit is integral — no interchangeable trip blocks to source separately, which simplifies BOM management for a panel builder. This part is in the current lifecycle stage, so it's still a standard catalog item, not a last-time-buy scavenger hunt. At 800 A and 600 VAC, this breaker is sized for the main incoming feeder or a large downstream sub-feed in an industrial distribution board. The 3-pole configuration covers three-phase loads — typical for motor control centers, large pump skids, or compressor banks. Mounting is standard for the Tmax XT6H frame size, so it fits the existing DIN-rail or panel-mount footprint of an ABB switchboard lineup. The 800 A frame gives you headroom for future load growth without swapping the entire breaker — the fixed trip is set at 800 A, but the frame itself is rated for that current continuously without derating concerns in a 40°C ambient.","metaTitle":"XT6HU3800DFF000XXX ABB Tmax XT6H 800A 3P Molded Case Circuit","metaDescription":"ABB Tmax XT6HU3800DFF000XXX molded case circuit breaker, 800A, 3-pole, 600VAC. Current lifecycle stage, available to order. Sourced and quoted against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":[],"specifications":{"Poles":"3","Current":"800 A","Product Type":"Breaker, Molded Case","Product Status":"Active"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/3d4ceeae48e4d7e03ac7ed417d684bc8.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/XT6HU3800DFF000XXX/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/XT6HU3800DFF000XXX","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/XT6HU3800DFF000XXX when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}