{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"XUAH0224","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"XUAH0224","canonicalUrl":"https://aoctrl.com/schneider/XUAH0224","factsUrl":"https://aoctrl.com/api/mcp/products/XUAH0224","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Telemecanique XUA-series tubular photoelectric through-beam detector, NC/PNP output, 2 m sensing range, 12-24 VDC, 3-wire 2 m PVR cable, order code XUAH0224.","salesMarkdown":"## The part on the bench The Schneider Telemecanique XUAH0224 is a tubular photoelectric through-beam detector in the miniature XUA series, built around a threaded nickel-plated brass housing with a PMMA lens. It pairs with a separate source unit on a 2 m optical axis — the listed sensing distance — and switches a DC load through a 3-wire PNP output. It runs on 12 to 24 VDC and sinks up to 100 mA on the switched leg, with an NC PNP output configuration and UL/CE approvals carried on the spec line. The 0.25 ms on/off response and 2000 Hz switching ceiling set the maximum detectable event rate, which matters on indexing conveyors or small-part counting stations where a slower sensor would miss a pulse. ## What the housing and termination actually mean Threaded nickel-plated brass housing sealed to NEMA 4/6/6P/12/13 and IP65, IP67, suits washdown and mild-chemical environments typical of food, beverage, and bottling lines. The 2 m PVR cable flying-lead termination commits cable gland entry and harness length at order time — a panel retro-fit needing a quick-disconnect should look at the 'S' suffix variant instead. ## Cable version vs. M8 connector variant The closest same-function sibling is the XUAH0224S, which carries the same 2 m range, NC/PNP output, 12-24 VDC supply, 100 mA load, 2000 Hz switching, and UL/CE approvals but terminates in an M8 3-pin DC nano male connector instead of the 2 m PVR cable. On a panel that was specified around the XUAH0224S the cable version will not drop in without re-terminating the harness or adding a cordset; the sensing performance is identical, the wiring is not. The XUAH0214S is the same M8-connector mechanical package but flips the output to NO/PNP, which is the right swap only if the PLC input was actually wired to look for a high-going edge — a NO/NC substitution is never silent on a safety or interlock circuit. The XUAH0224 carries a current lifecycle stage, and the XUA series remains a current Telemecanique / Square D family in the Schneider line, so this is still a supported order code rather than a last-time-buy.","metaTitle":"Schneider XUAH0224 Photoelectric Sensor, 2 m, 12-24 VDC","metaDescription":"Schneider XUAH0224 tubular through-beam photoelectric sensor, NC/PNP, 2 m sensing range, 12-24 VDC, 2 m PVR cable. UL/CE listed. Quoted to order against an RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Photoelectric Sensors"],"specifications":{"UPC":"78590173802","Model":"XUA","title":"XUAH0224","Used On":"XUA SERIES MINIATURE PHOTOELECTRIC SENSOR","Category":"Photoelectric Sensors","Material":"NICKEL PLATED BRASS","Enclosure":"NEMA 4/6/6P/12/13, IP65, IP67","Brand Name":"Telemecanique[R]","description":"Telemecanique XUAH0224 Photo-Electric Sensor 30V 18Ma Options (Nri)|Telemecanique XUAH0224 Photo-Electric Sensor 30V 18Ma Options (Nri)","Construction":"THREADED","Sub-Category":"Tubular Photoelectric Through Beam Detector","UPC 12 Digit":"389110427212","Response Time":"0.25 MILLISECOND (ON/OFF)","Connection Type":"2 M PVR CABLE","Number of Wires":"3","lifecycle_stage":"current","Sensing Distance":"2 M","Operating Voltage":"12 TO 24 VDC","Manufacturer Brand":"Square D Co.","Product Description":"Telemecanique XUAH0224 Photo-Electric Sensor 30V 18Ma Options (Nri)","Additional Information":"APPROVAL UL, CE; OUTPUT CONFIGURATION NC, PNP; MAXIMUM LOAD CURRENT 100 MILLIAMPERE; SWITCHING FREQUENCY 2000 HZ; LENS MATERIAL PMMA","Full Technical Description":"Nickel Plated Brass Material; Xua Series Miniature Photoelectric Sensor Used on; 2 M PVR Cable Connection Type; 3 Wire(S); 12 to 24 VDC Operating Voltage; NEMA 4/6/6P/12/13, IP65, IP67 Enclosure; Threaded Construction; 2 M Sensing Distance; 0.25 Millisecond (On/Off) Response Time; TELEMECANIQUE[R] Brand; Approval UL, CE; Output Configuration NC, PNP; Maximum Load Current 100 Milliampere; Switching Frequency 2000 Hz; Lens Material Pmma; XUA Model","Proposition 65 Warning (CA)":"WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$44.45","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/4abe99778b22a5631b410f421af4602a.pdf","sourceUrl":null},"ai":{"faq":[{"question":"Will the XUAH0224 drop into a panel specified around the XUAH0224S without rewiring?","answer":"No. Sensing distance, output configuration, load current, and supply voltage are identical, but the XUAH0224 terminates in a 2 m PVR cable while the XUAH0224S uses an M8 3-pin DC nano male connector. A drop-in requires either re-terminating the harness or fitting a mating cordset."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/XUAH0224","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/XUAH0224 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}