{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"XUB0AKSNL2T","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"XUB0AKSNL2T","canonicalUrl":"https://aoctrl.com/schneider/XUB0AKSNL2T","factsUrl":"https://aoctrl.com/api/mcp/products/XUB0AKSNL2T","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Telemecanique XUB0AKSNL2T, XUB Series tubular photoelectric through-beam emitter, 20 m sensing distance, 12-24 VDC, 3-wire PVC cable, IP67, plastic housing.","salesMarkdown":"## 20 m through-beam emitter — range sets the pair spacing The XUB0AKSNL2T is the emitter half of a through-beam photoelectric pair, rated for a 20 m sensing distance between emitter and receiver. That range covers long conveyor lanes, automated warehouse aisles, and wide machine access zones where a single sensor pair spans the full gap. Response time is 2 ms — fast enough to catch parts moving at several meters per second on a packaging line, but check that the downstream PLC input filter is set to at least 500 Hz to avoid missing pulses. ## 12-24 VDC, 3-wire — wiring constraints for the integrator Runs on 12 to 24 VDC nominal, 3-wire configuration (brown/blue/black) with a 2 m PVC cable pre-attached. The third wire is the switched output — typically PNP NO for sinking PLC inputs. No separate power supply needed if the control cabinet already has a 24 VDC bus. The plastic barrel (18 mm diameter, front sensing) eliminates corrosion concerns in washdown environments compared to nickel-plated brass housings found on older XU2 series sensors. Mounts in standard 18 mm through-hole brackets or clamp mounts. ## IP67, NEMA 4X/12 — enclosure rating for wet or dusty lines IP67 and NEMA 4X/12 mean the sensor body and cable entry are sealed against hose-directed water and dust ingress. Suitable for food processing washdown, outdoor conveyor systems, and machining coolant spray — the PMMA lens resists many industrial chemicals and cleaning agents. ## Sourcing and lifecycle — active, quoted to order For volume purchases or scheduled releases, the 2 m cable length and plastic housing are the fixed configuration — no field-interchangeable connector option on this variant. The UPC is 78590150983 for traceability in procurement systems.","metaTitle":"Schneider Electric XUB0AKSNL2T Photoelectric Sensor, 20 m","metaDescription":"Telemecanique XUB0AKSNL2T through-beam emitter, 20 m range, 12-24 VDC, IP67, 2 ms response. UL/CSA/CE. Active production — quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Photoelectric Sensors"],"specifications":{"UPC":"78590150983","Model":"XUB","title":"XUB0AKSNL2T","Used On":"XUB SERIES PHOTOELECTRIC SENSOR","Category":"Photoelectric Sensors","Material":"PLASTIC","Enclosure":"NEMA 4X/12, IP67","Brand Name":"OSICONCEPT[T]","description":"SQUARE D XUB0AKSNL2T: PHOTOELECTRIC SENSOR 18MM EMITTER XUB","Sub-Category":"Tubular Photoelectric Through Beam Source","UPC 12 Digit":"389110148254","Response Time":"2 MILLISECOND","Connection Type":"2 M PVR CABLE","Number of Wires":"3","lifecycle_stage":"current","Sensing Distance":"20 M","Sensing Position":"FRONT","Operating Voltage":"12 TO 24 VDC","Manufacturer Brand":"Square D Co.","Product Description":"Telemecanique XUB0AKSNL2T Photo-Electric Sensor 18Mm Emitter Xub","Operating Temperature":"-13 TO 131 DEG F","Additional Information":"APPROVAL UL, CSA, CE; LENS MATERIAL PMMA","Full Technical Description":"Plastic Material; Xub Series Photoelectric Sensor Used on; 2 M PVR Cable Connection Type; 3 Wire(S); 12 to 24 VDC Operating Voltage; NEMA 4X/12, IP67 Enclosure; -13 to 131 Deg F Operating Temperature; 20 M Sensing Distance; 2 Millisecond Response Time; Front Sensing Position; OSICONCEPT[T] Brand; Approval UL, CSA, CE; Lens Material Pmma; XUB Model","Proposition 65 Warning (CA)":"WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$22.86","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2b22d7596fdaf03fbff6d810e18ecb9e.pdf","sourceUrl":null},"ai":{"faq":[{"question":"How can I order XUB0AKSNL2T or check availability?","answer":"This part is sourced through independent distribution and quoted to order against your BOM quantity. Submit an RFQ for current pricing and lead time; availability is confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/XUB0AKSNL2T","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/XUB0AKSNL2T when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}