Skip to main content
Schneider Electric A9R81463 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric A9R81463 Acti9 iID RCCB, 63 A, 30 mA, 4P

MPNA9R81463
Active

Schneider Electric Acti9 iID, RCCB, 4P, 63 A, 30 mA, Type AC, 380-415 V AC, clip-on DIN rail.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9R81463 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)30 mA
Earth-leakage protection class / typeType AC
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
A9R81463 — Electrical Ratings
ParameterValue
Rated current (In)63 A
Rated operational voltage (Ue)380...415 V AC 50/60 Hz
Poles description4P
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Device location in systemOutgoer
Electrical durabilityAC-1: 15000 cycles
Mechanical durability (operating cycles)20000 cycles
A9R81463 — Identification
ParameterValue
Product nameActi9 iID
Product / component typeResidual current circuit breaker (RCCB)
Product range / familyActi9
Device short nameiID
A9R81463 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules8
Terminal connectionsSingle terminal top or bottom 1...35 mm² rigid Single terminal top or bottom 1...25 mm² flexible Single terminal top or bottom 1...25 mm² flexible with ferrule
Wire stripping length14 mm for top or bottom connection
Terminal tightening torque3.5 N.m top or bottom
Width72 mm
Height91 mm
Depth73.5 mm
A9R81463 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
A9R81463 — Approvals
ParameterValue
StandardsEN/IEC 61008-1

Product details

The Schneider Electric A9R81463 is a 4-pole residual current circuit breaker (RCCB) from the Acti9 iID series, rated at 63 A with 30 mA earth-leakage sensitivity. Mounts via clip-on to a DIN rail, occupying 8 x 9 mm pitches (72 mm wide). Rated breaking capacity is 1500 A (Idm and Im), sufficient for most sub-distribution outgoing circuits.

The 63 A rated current (In) and 30 mA sensitivity define the two critical selection parameters: the breaker must be sized to the load current (63 A is typical for a large sub-main or a high-power final circuit), and the 30 mA trip threshold provides personnel protection against direct-contact faults. The instantaneous trip time (no intentional delay) means it clears ground faults immediately — no selectivity with downstream 30 mA RCCBs, but full coordination with upstream time-delay types. Type AC classification (EN/IEC 61008-1) limits this RCCB to sinusoidal AC residual currents. If the downstream load includes variable-speed drives, UPS systems, or LED drivers that can generate pulsed or DC fault currents, a Type A or Type B RCCB would be required instead. For standard resistive, inductive, or motor loads on a clean sine-wave supply, Type AC is the correct and most economical choice. Rated insulation voltage (Ui) is 500 V AC, operational voltage range is 380-415 V AC. Pollution degree 3 rating confirms installation in conductive or dry non-conductive pollution.

Integration notes

The IP20 body (IP40 in a modular enclosure) suits dry indoor panels — not washdown or outdoor locations. The voltage-independent residual current tripping technology means the RCCB will trip on a ground fault even if the phase voltage is lost — a safety advantage over electronic types that require auxiliary power. The 8/20 µs impulse withstand of 250 A ensures it does not nuisance-trip on transient surges.

Frequently asked questions

What is the breaking capacity of A9R81463?

The rated breaking and making capacity (Idm and Im) is 1500 A, sufficient for outgoing circuits in most sub-distribution panels.

MPN
A9R81463