Schneider Electric A9R84463 — Residual Current Breakers (RCCB/RCBO)

A9R84463 Acti9 iID RCCB, 63A, 300mA, 4P, Type AC

MPNA9R84463
Obsolete

Schneider Electric Acti9 iID, A9R84463, Residual current circuit breaker (RCCB), 4P, 63 A, 300 mA, Type AC, 380...415 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

A9R84463 — Residual Current Protection
ParameterValue
Earth-leakage sensitivity (IΔn)300 mA
Earth-leakage protection class / typeType AC
Earth-leakage trip time delayInstantaneous
Residual-current tripping technologyVoltage independent
A9R84463 — Electrical Ratings
ParameterValue
Rated current (In)63 A
Rated operational voltage (Ue)380...415 V AC 50/60 Hz
Poles description4P
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)6 kV
Device location in systemOutgoer
Electrical durabilityAC-1: 15000 cycles
Mechanical durability (operating cycles)20000 cycles
A9R84463 — Identification
ParameterValue
Product nameActi9 iID
Product / component typeResidual current circuit breaker (RCCB)
Product range / familyActi9
Device short nameiID
A9R84463 — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeClip-on
Control typeToggle
Width in 9 mm modules8
Terminal connectionsSingle terminal top or bottom 1...35 mm² rigid Single terminal top or bottom 1...25 mm² flexible Single terminal top or bottom 1...25 mm² flexible with ferrule
Wire stripping length14 mm for top or bottom connection
Terminal tightening torque3.5 N.m top or bottom
Width72 mm
Height91 mm
Depth73.5 mm
A9R84463 — Environmental
ParameterValue
Operating ambient temperature-5...60 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
A9R84463 — Approvals
ParameterValue
StandardsEN/IEC 61008-1

Product details

The Schneider Electric A9R84463 is a 4-pole residual current circuit breaker (RCCB) from the Acti9 iID range, rated for 63 A continuous current with a 300 mA earth-leakage sensitivity. The 300 mA threshold is typical for whole-building or submain protection where a lower 30 mA trip would cause nuisance tripping from normal cable leakage.

Breaking and making capacity is rated at 1500 A (Idm and Im) — this is the short-circuit withstand capability of the RCCB itself; upstream protection (MCB or fuse) must limit fault current to this level. The device is voltage-independent for tripping: the residual current detection and mechanical trip mechanism operate without needing an external power supply, so it still protects even if the neutral is lost upstream. Earth-leakage protection is instantaneous (no intentional time delay), so it trips within the standard response time of an RCCB — typically under 40 ms at rated residual current. This makes it suitable for outgoing feeders where fast disconnection is required, but not for selectivity with downstream 30 mA RCCBs unless coordinated by cascading.

Installation and wiring notes

Wire stripping length is 14 mm. The device occupies 8 modular pitches (9 mm each), so it needs 72 mm of DIN rail space. The contact position indicator shows whether the contacts are open or closed — useful during commissioning and fault finding.

Frequently asked questions

What is the A9R84463 used for?

It is a 4-pole residual current circuit breaker (RCCB) used for earth-leakage protection on three-phase outgoing feeders in low-voltage distribution boards. It trips on sinusoidal AC residual currents at 300 mA threshold, protecting against indirect contact and fire risk from earth faults.

What standards does the A9R84463 comply with?

It complies with EN/IEC 61008-1, the standard for residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs). It also carries an 8/20 µs impulse withstand rating of 250 A per that standard.

What is the difference between Type AC and Type A RCCBs?

Type AC (this device) detects sinusoidal AC residual currents only. Type A detects both sinusoidal AC and pulsating DC residual currents (e.g., from rectified loads like variable-speed drives, LED drivers, or EV chargers). For circuits with electronics, a Type A or Type B RCCB is typically required by code.

Where can I buy the A9R84463?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm offer.

MPN
A9R84463