Schneider Electric ATS130N2D65LT
MPNATS130N2D65LT
Active
Altivar Soft Starter ATS130, 65A, 200 to 480V AC, control supply 24V DC
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
Specifications
| Parameter | Value |
|---|---|
| Display type | 1 LED Green)control power energized 1 LED yellow and red)motor operation phases, errors |
| Protection type | Phase failure mains Thermal protection starter Bypass error starter Control voltage Us starter |
| Range of product | Altivar Soft Starter ATS130 |
| Relay output type | Relay outputs R1A, R1C NO |
| Discrete input type | DI) digital input, 10 kOhm DI2) digital input, 10 kOhm BOOST) digital input, 10 kOhm |
| Discrete output type | Non programmable digital output DQ1 <= 30 V 200 mA |
| Product or component type | Soft starter |
| Ue power supply voltage | 200...480 V - 15...10 % |
| Coil voltage | 24 V DC |
| [Us] control circuit voltage | 24 V DC +/- 10 % |
| Voltage | 480 V |
| [Uimp] rated impulse withstand voltage | 4 kV |
All specifications
| Parameter | Value |
|---|---|
| Minimum motor current | 20 % Ie |
| Overload current profile | 300 % Ie for 5 s |
| Maximum switching current | On resistive load for relay outputs : 1 A 250 V AC 400000 cycles On resistive load for relay outputs : 1 A 30 V DC 400000 cycles On inductive load for relay outputs : 1 A 250 V AC cos phi = 0.4 100000 cycles On inductive load for relay outputs : 1 A 30 V DC cos phi = 0.4 100000 cycles |
| Minimum switching current | 2.5 mA 24 V DC relay outputs |
| [Ie] rated operational current | 65 A in line 104 °F (40 °C)) |
| Power loss static current independent | 3 W |
| [In] rated current pwr loss specifctn | 65 A |
| Power loss per device current dependent | 16 W |
| Control power | 21.6 W starting and stopping 3 W steady state |
| Motor power | 18.5 kW 230 V normal duty 30 kW 400 V normal duty 37 kW 440 V normal duty |
| Power supply frequency | 50...60 Hz +/- 5 Hz |
| Maximum horse power rating | 20 hp 200 V normal duty 20 hp 208 V normal duty 20 hp 230 V normal duty 40 hp 460 V normal duty 50 hp 480 V normal duty |
| Power loss during starting | 397 W 300 % Ie |
| Phases | 3 phase |
| Utilisation category | AC-53A |
| IP degree of protection | IP20 |
| Suitable for mounting onto standard rails | True |
| Device connection | In line |
| Pollution degree | Level 2 |
| Relative humidity | 5...95 % non condensing without dripping water IEC 60068-2-3 |
| Operating altitude | 0...3280.84 ft (0...1000 m) without derating 3280.84...13123.36 ft (1000...4000 m) 1 % per 100 m |
| Maximum acceleration under shock load (during storage) | 100 m/s² at 11 ms |
| Maximum acceleration under shock load (during transport) | 100 m/s² at 11 ms |
| Maximum acceleration under shock impact (during operation) | 100 m/s² at 11 ms |
| Maximum acceleration under vibrational stress (during operation) | 10 m/s² at 9...200 Hz |
| Depth | 6.5 in (165 mm) |
| Width | 2.2 in (55 mm) |
| Height | 6.5 in (166 mm) |
| Standards | EN/IEC 60947-4-2 UL 60947-4-2 IEC 60664-1 |
| Marking | CE CCC UKCA RCM EAC |
| On-load factor | 70 % |
| Internal bypass | True |
| Device short name | ATS130 |
| Function available | Deceleration voltage ramp Boost |
| Operating position | Vertical +/- 30 degree |
| Input compatibility | discrete input level 1 PLC EN/IEC 61131-2 |
| Product destination | Asynchronous motors |
| Relay output number | 1 |
| Discrete input logic | Digital input 0...< 5 V <= 0.2 mA > 13 V, >= 0.5 mA |
| Service factor at ie | 100 |
| Discrete input number | 3 |
| Operating cycles (hour) | 13 cyc/h |
| Discrete output number | 1 |
| Display screen available | False |
| Product specific application | Simple machine |
| Electromagnetic compatibility | Conducted and radiated emissions level B conforming to IEC 60947-4-2 Short voltage interruptions level 3 conforming to IEC 61000-4-11 Electrostatic discharge level 2 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 1 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 2 conforming to IEC 61000-4-4 Oscillatory waves immunity level 3 conforming to IEC 61000-4-12 Voltage/current impulse level 2 conforming to IEC 61000-4-5 Conducted disturbances, induced by radiofrequency fields level 1 conforming to IEC 61000-4-6 |
| Ambient air transport temperature | -40...158 °F (-40...70 °C) |
| Ambient air temperature for storage | -13...158 °F (-25...70 °C) |
| Integrated motor overload protection | False |
| Ambient air temperature for operation | 14...104 °F (-10...40 °C) (without derating) 104...140 °F (40...60 °C) (with current derating 1.5 % per °C) |
| Environmental class (During operation) | Without salt mist 3C3 IEC 60721-3-3 3S3 IEC 60721-3-3 |
| Maximum deflection under vibratory load (during storage) | 3 mm at 2-9 Hz |
| Maximum acceleration under vibratory load (during storage) | 10 m/s² at 9...200 Hz |
| Maximum deflection under vibratory load (during operation) | 3 mm at 2-9 Hz |
| Maximum deflection under vibratory load (during transport) | 3 mm at 2-9 Hz |
| Maximum acceleration under vibratory load (during transport) | 10 m/s² at 9...200 Hz |
MPN
ATS130N2D65LT