Schneider Electric ComPacT NSXm, 3-pole circuit breaker, 100 A TM-D thermal-magnetic trip, 50 kA at 415 V AC, EN/IEC 60947-2, grey RAL 7016.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C11N3TM100B — Identification
ParameterValue
Product nameComPacT NSXm
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C11N3TM100B — Ratings
ParameterValue
Rated current (In)100 A at 40 °C
Poles configuration3P
Rated operational voltage (Ue)440 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C11N3TM100B — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Electrical durability (cycles)20000 cycles at 440 V In/2 10000 cycles at 440 V In
Mechanical durability (cycles)20000 cycles
C11N3TM100B — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
Local signalling/indicationFlag (green) for presence of auxiliary contacts
Number of 9 mm pitches9 module
C11N3TM100B — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C11N3TM100B — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C11N3TM100B — Electrical
ParameterValue
[Icu] rated ultimate short-circuit breaking capacity90 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity90 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
C11N3TM100B — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

What the 50 kA breaking capacity means for your panel

Mounting and integration into a standard enclosure

The breaker occupies 9 module pitches (81 mm wide, 137 mm high, 80 mm deep) and mounts to a backplate — not a DIN rail — in either horizontal or vertical orientation. Front-facing connection terminals accept compression lugs or busbars; the connection pitch is 35 mm with spreaders or 27 mm without. That 9-module footprint is the first thing to check against your enclosure's gland-plate layout and phase-busbar centres. IP40 front-of-panel protection is fine for general-purpose indoor distribution; IK07 impact resistance handles the occasional tool bump during commissioning.

What the TM-D trip unit and 100 A rating govern

The thermal-magnetic TM-D trip provides fixed overload protection (thermal curve) and short-circuit magnetic pickup. Power dissipation is 7.5 W per pole — 22.5 W total at full load — so account for that heat in a sealed enclosure.

Electrical and mechanical endurance

Rated for 20,000 mechanical cycles and 20,000 electrical cycles at 440 V at rated current (In/2 duty — switching half the rated load). The breaker is category A — no intentional short-time delay, so it trips instantaneously on magnetic pickup.

Frequently asked questions

Where can I buy the C11N3TM100B and how is it quoted?

The C11N3TM100B is sourced and quoted to order through independent distribution. Availability and current pricing are confirmed at quote time against an RFQ — no stock count or price is published here.

What is the closest alternative to the C11N3TM100B in the same family?

Within the ComPacT NSXm range, the closest alternative would be a different trip-unit rating or breaking capacity variant on the same 160 N frame. The C11N3TM100B is the 100 A TM-D version; a 63 A or 125 A TM-D variant on the same frame would share the same footprint and connection pitch, changing only the thermal-magnetic calibration.

What compliance documentation does Schneider provide for the C11N3TM100B?

The breaker is certified to EN/IEC 60947-2 and carries a suitability-for-isolation marking per that standard. It is rated for pollution degree 3 and overvoltage category III. RoHS and REACH declarations are standard for Schneider's current ComPacT range, though the specific document revision should be confirmed at order time.

MPN
C11N3TM100B