Schneider Electric C254MG200D — Miniature Circuit Breakers (MCB)

Schneider Electric C254MG200D ComPacT NSX250 DC Trip Unit, 2

MPNC254MG200D
Active

Schneider Electric ComPacT NSX250 DC series, TM-G trip unit, C254MG200D, 200A at 40°C, 750V DC, 4 poles, LI thermal-magnetic protection, generator application.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C254MG200D — Identification
ParameterValue
Product rangeComPacT
Product range (series)ComPacT NSX100...250 DC
Product/component typeTrip unit
Device applicationGenerator
C254MG200D — Ratings
ParameterValue
Poles configuration4P
Rated operational voltage (Ue)750 V DC
Network type (AC/DC)DC
C254MG200D — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
C254MG200D — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60947-1
C254MG200D — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C254MG200D — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

The Schneider Electric C254MG200D is a TM-G thermal-magnetic trip unit for the ComPacT NSX100...250 DC range, rated 200 A at 40 °C and designed for DC networks up to 750 V DC. The trip unit is intended for generator protection applications, meaning its curve and pickup settings are tuned for the inrush and fault characteristics of generator circuits.

The 200 A rating at 40 °C sets the continuous current the trip unit can carry without nuisance tripping — a generator feeder sized for 200 A continuous load is the target. The instantaneous pickup is fixed at 530 A, which is 2.65× In, a typical magnetic threshold for generator protection that avoids tripping on motor starting inrush while clearing hard faults. The long-time pickup (Ir) is adjustable from 0.7 to 1.0× In, giving the commissioning engineer ±30% flexibility to match the actual generator nameplate without swapping the trip unit. Rated operational voltage of 750 V DC covers common 500 VDC and 750 VDC battery banks, solar string combiners, and DC bus systems — the 4-pole series configuration handles the higher DC voltage by splitting the arc across multiple gaps.

Integration notes

The trip unit mounts into a ComPacT NSX250 DC fixed circuit breaker. The 4-pole configuration occupies the full width of the breaker frame.

Frequently asked questions

Where can I buy C254MG200D and get a price?

The C254MG200D is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial offer.

What is the closest alternative to C254MG200D in the ComPacT family?

Within the ComPacT NSX250 DC platform, the closest sibling is a trip unit with a different rating or protection curve (e.g., a TM-D for distribution instead of TM-G for generator). The TM-G curve is specific to generator protection; a TM-D unit would have different instantaneous pickup and may nuisance-trip on generator inrush. Verify the application before substituting.

What standards does C254MG200D comply with?

The C254MG200D complies with EN/IEC 60947-2, the international standard for low-voltage switchgear and controlgear. It also carries pollution degree 3 per IEC 60947-1 and IP40 per IEC 60529.

MPN
C254MG200D